KLASCHKA BDK/I-1.4 Manual de usuario

Double Sheet Monitor BDK/I-1.4
BDK Compact Ref. no. 20.21-03
© by Klaschka GmbH & Co. KG • Steinegger Str. • D-75233 Tiefenbronn • Fon +49 7234 79 0 • Fax +49 7234 79 112 • e-mail: [email protected] • www.klaschka.de
KLASCHKA KB 7.11 BDK 1/5
Features
One-channel compact Double Sheet Monitor for the connec-
tion of one sensor for single-surface contact measurement of
ferrous (Fe) sheets.
Application
The BDK Compact Double Sheet Monitor can be used wher-
ever you need to be sure that ferrous metal sheets do not
exceed a specified thickness (double sheet), and/ or to trans-
mit the measured sheet thickness as an analogue value for
processing in a control system.
Configuration
The Double Sheet Monitor has a sturdy plastic housing. The
ready-made connecting leads permit quick and easy connec-
tion of the metal thickness sensor. A 9-pole M23 connector
allows to connect the supply voltage, the controlling signals
and the analogue output.
Mounting
instructions
The sensor can be mounted into the suction cup of the grip-
per or into a monitoring station. For measurement, the com-
plete sensing face of the sensor must be covered by the
sheet.
Mode of operation
The metal thickness sensor DSP for single-surface, non-
contact measurement is used to monitor sheets for double
thicknesses in the range 0.15 to 4 mm. During measure-
ment, an excitation coil generates a strong magnetic field.
The sheet is briefly drawn towards the coil and magnetised
to saturation. A sensor coil measures the magnetic flux, the
evaluation device linearises the measured value and trans-
forms it into an analogue voltage. Measurement can be
started by an external signal or pressing a key on the control
panel. If a continuous start signal is employed, measurement
is carried out every 500 ms.
The teaching in of the current sheet which is to be monitored
takes place by the control panel or the external Teach-In sig-
nal. During this learning procedure three measurements take
place. The resulting sheet thickness is stored as reference
value. When the measured sheet is more than 1.3 times
thicker than the reference sheet, „Double sheet“ is signalled.
When the measured sheet is more than 0.5 times thinner
than the reference sheet, „No sheet“ is signalled. When a
double sheet is detected, the switching output for 1 sheet
changes from Hi to Lo.
Operation
The four operator keys on the front panel of the device allow
to operate the BDK:
Start Manual start of a measurement
- Decrement limit-value or calibrate Zero-value
+ Increment limit-value or calibrate End-value
Teach Programming of the reference sheet
Display
In addition, 5 LEDs indicate the result of the current meas-
urement.
Light Fields:
Measurement Lights up during the measurement
Sensor Lights up when sheet is detected by the
sensor
0-sheet Lights up if no sheet is in front of the
sensor or the measured value is below
the lower value.
1-sheet Lights up on output of 1-sheet message
2-sheets Lights up on output of 2-sheet message

BDK/I-1.4 Double Sheet Monitor
Ref. no. 20.21-03 BDK Compact
© by Klaschka GmbH & Co. KG • Steinegger Str. • D-75233 Tiefenbronn • Fon +49 7234 79 0 • Fax +49 7234 79 112 • e-mail: [email protected] • www.klaschka.de
2/5 BDK KB 7.11 KLASCHKA
Commissioning
When the device is used for the first time or when a compo-
nent of the system is changed, a calibration of the system
(range of measurement) has to be performed. For this, the
zero value (value without sheet) and the end value – with a
4 mm sheet (DSP -54sg-2s) – must be programmed. When
using the DSP -36sg-2s, the programming takes place with a
2 mm sheet.
The calibration will be performed as follows:
Remove the sheet from the sensor and press the button “-“
for 2 seconds until the LED 0-sheet lights up. Keep then the
button “-“ pressed and press “Start”. The device will now
automatically perform three measurements and calculate the
zero value. Place then the 4 mm or 2 mm sheet on the sen-
sor (will be attached to the respective sensor) and press the
button “+” for 2 seconds until the LED “2-sheets“ lights up.
Keep then the button “+“ pressed and press “Start”. Again,
three measurements will be performed and the end value be
calculated. A reference sheet is delivered together with the
sensor.
Timing diagram: commissioning
Teach-In
The programming of the sheet to be monitored can take
place either by an external signal like a PLC-signal or by
pushing the button “Teach” on the front panel of the device.
For this function the respective sheet has to be placed on the
sensor.
Internal programming through the front panel:
Place the sheet on the sensor and push the button „Teach”
for 2 seconds until only the LED “1-sheet” lights up. Keep
then the button “Teach” pressed and press “Start”. Three
measurements take place automatically for the calculation of
the threshold value.
External programming through the controller:
Place the sheet on the sensor and supply a 24 V signal to
the input for Teach-in for more than 1 second. After one sec-
ond the LED 1-sheet lights up and the device will perform the
measurements and calculation of threshold like described for
internal programming.
The threshold for double sheet detection lies thereby at the
1.3-fold thickness value of the reference sheet. The thres-
hold can be changed manually in 10 % steps using the but-
ton “Teach” and the two buttons “+” and “-”. The three LEDs
for “0-, 1- and 2-sheet(s)” indicate the set threshold. For a
short time (appox. 5 s) during the setup or by a short touch of
the button “Teach” the analogue output delivers in addition
the set threshold value for double sheet detection.
Timing diagram: Teach-in - internal
Timing diagram: Teach-in - external
Timing diagram: manually changed threshold
Threshold: LED
Reference sheet
x 0 sheet 1 sheet 2 sheets
1.1 ON OFF OFF
1.2 ON ON OFF
1.3 ON ON ON
1.4 OFF ON ON
1.5 OFF flashes ON
1.6 OFF OFF ON
1.7 OFF OFF flashes
Teach-In
internal
Ana-
logue
value
Teach-In
external
LED
2-Sheets
LED
0-Sheet
LED
2-Sheets
Teach-In
internal
LED
2-Sheets

Double Sheet Monitor BDK/I-1.4
BDK Compact Ref. no. 20.21-03
© by Klaschka GmbH & Co. KG • Steinegger Str. • D-75233 Tiefenbronn • Fon +49 7234 79 0 • Fax +49 7234 79 112 • e-mail: [email protected] • www.klaschka.de
KLASCHKA KB 7.11 BDK 3/5
Outputs
The Double Sheet Monitor BDK/I-1.4 delivers after each
measurement the instantaneous result for “0-, 1-, and 2-
sheet(s)” message over two semiconductor outputs to a PLC
for further processing.
Outputs:
Sheets 0- sheet message 1- sheet message
undersize 1 0
1 0 1
2 0 0
Diagram: Measurement procedure
Timing diagram: Measurement
Connection diagram
Connections
XS1: Pin assignment for PLC-connection
1 +24 V DC (1 qmm)
2 M (1 qmm)
3 0-sheet message
4 1-sheet message
5 signal for Start
6 signal for Teach-in
7 analogue output 0 … 20 mA
8 analogue output M
9 - -
Housing shield (optional)
XS2: Pin assignment of sheet thickness sensor
1 +24 V DC
2 Temperature sensor
3 M
4 Temperature sensor
5 Sensor
6 IN
7 OUT-1
8 OUT-2
9 - -
Housing shield
8 1
7 2
63
54
9
1 8
2
7
3
6
45
9
Analogue
output
2 Sheets

BDK/I-1.4 Double Sheet Monitor
Ref. no. 20.21-03 BDK Compact
© by Klaschka GmbH & Co. KG • Steinegger Str. • D-75233 Tiefenbronn • Fon +49 7234 79 0 • Fax +49 7234 79 112 • e-mail: [email protected] • www.klaschka.de
4/5 BDK KB 7.11 KLASCHKA
Dimensions of the housing
Type
Ref. no.
Meas. range
mm
Max. thick-
ness mm
Meas.
time ms
L
mm
l
mm
G
Thread A/f Weight
g
DSP-36sg-2s
DSP-54sg-2s
13.05-96
13.05-95
0.15 … 2
0.15 … 4
1.5
3.5
< 30
< 50
90
107
65
81
M36 x 1.5
M54 x 0.75
55
65
380
1200

Double Sheet Monitor BDK/I-1.4
BDK Compact Ref. no. 20.21-03
© by Klaschka GmbH & Co. KG • Steinegger Str. • D-75233 Tiefenbronn • Fon +49 7234 79 0 • Fax +49 7234 79 112 • e-mail: [email protected] • www.klaschka.de
KLASCHKA KB 7.11 BDK 5/5
Technical data
Double Sheet Monitor BDK/I-1.4
Supply voltage U
B
19 … 24 … 30 V DC
Current consumption max. 3.5 A
Operating temperature 0 … + 55 °C
Inputs
Start signal Hi = 12 … 24 … 30 V DC
Lo = 0 … 5 V DC
Input current C 5 mA ( for 24 V DC)
Electrical isolation no
Teach-In Hi = 12 … 24 … 30 V DC
Lo = 0 … 5 V DC
Input current approx. 5 mA (for 24 V DC)
Electrical isolation no
Outputs
Switching output Semiconductor output, plus
switching, resistant to short
circuit
Output current U
B
– 1.75 V
Analogue output max. 100 mA
Electrical isolation no
Analogue output Current
Output current 0 … 20 mA
Load resistance ≤500 Ω
Electrical isolation no
Linearity / Resolution 5 % / 256 steps
Measuring time < 50 ms
Repetition time 500 ms
Housing, B / H / T 200 / 180 / 60 mm
Weight approx. 700 g
Sheet Metal Thickness Sensor
Measurement method saturation induction
DSP-m54sg-2s
Measurement range 0.15 … 4 mm
Sheets until max. 3.5 mm
Diameter 54 mm
Total length 120 mm
Thread M54 x 0.75
Weight approx. 1200 g
DSP-m36sg-2s
Measurement range 0.15 … 2 mm
Sheets until max. 1.5 mm
Diameter 36 mm
Total length 135 mm
Thread M36 x 1.5
Weight approx. 380 g
Order data
BDK/I-1.4 Ref. no. 20.21-03
Double Sheet Monitor Compact
DSP-54sg-2s Ref. no. 13.05-95
Sheet Metal Thickness Sensor for BDK/I-1.4
(Sheet thickness max. 3.5 mm)
DSP-36sg-2s Ref. no. 13.05-96
Sheet Metal Thickness Sensor for BDK/I-1.4
(Sheet thickness max. 1.5 mm)
Connecting leads
All connecting leads are oil-resistant and suitable for drag
chains. The maximum lead length is 20 m and must be indi-
cated when ordering.
(standard length = 5 m, 10 m)
VLG9/2+4PS/5-5 5 m Ref. no. 20.18-93-050
Connecting lead BDK <--> Sensor,
Straight plug on sensor end.
VLG9/2+4PS/10-5 10 m Ref. no. 20.18-93-100
Connecting lead BDK <--> Sensor,
Straight plug on sensor end.
VLG9/2+4PS/5-6 5 m Ref. no. 20.18-94-050
Connecting lead BDK <--> Sensor,
Angled plug on sensor end.
VLG9/2+4PS/10-6 10 m Ref. no. 20.18-94-100
Connecting lead BDK <--> Sensor,
Angled plug on sensor end.
Lead box (socket)
SPF9-1 Ref. no. 13.99-08
Lead box (socket) for connecting power
supply and control leads.
Subject to changes!