Keysight Technologies 82351B Manual de usuario

Keysight 82351B
PCIe®-GPIB Interface
Quick Start
Guide
Keysight 82351B
PCIe®-GPIB Interface
Quick Start
Poster

2 Keysight 82351B Quick Start Poster
Safety Notices
CAUTION
A CAUTION notice denotes a
hazard. It calls attention to an
operating procedure, practice, or
the like that, if not correctly
performed or adhered to, could
result in damage to the product or
loss of important data. Do not
proceed beyond a CAUTION notice
until the indicated conditions are
fully understood and met.
WARNING
A WARNING notice denotes a
hazard. It calls attention to an
operating procedure, practice, or
the like that, if not correctly
performed or adhered to, could
result in personal injury or death.
Do not proceed beyond a
WARNING notice until the
indicated conditions are fully
understood and met.
Safety and EMC
Information
The 82351B is safety-certified in
compliance with EN61010-1:2010
standard. EMC is designed in
compliance with IEC 61326-1:2005
/ EN61326-1:2006 standard.
Safety symbols
Earth (ground) terminal
Caution, risk of danger
(refer to the manual for
specific Warning or
Caution information)
2 Keysight 82351B Quick Start Poster
For further safety information details, refer to the
Keysight 82351B PCIe®-GPIB Interface User’s Guide.

3 Keysight 82351B Quick Start Poster
Keysight 82351B Quick Start Poster 3
Regulatory Markings
The CE mark is a conformity marking of the European
Community. This CE mark shows that the product
complies with all the relevant European Legal
Directives.
ICES/NMB-001 indicates that this ISM device
complies with Canadian ICES-001.
The RCM mark is a registered trademark of the
Spectrum Management Agency of Australia. This
signifies compliance with the Australia EMC
Framework regulations under the terms of the Radio
Communication Act of 1992.
This instrument complies with the WEEE Directive
(2002/96/EC) marking requirement. This affixed
product label indicates that you must not discard this
electrical/electronic product in domestic household
waste.
This symbol is a South Korean Class A EMC
Declaration. This is a Class A instrument suitable for
professional use and in electromagnetic environment
outside of the home.
WARNING
– Do not use the device if it appears damaged or
defective.
– Observe all markings on the device before
connecting any wiring to the device.
– Do not operate the device in the presence of
flammable gases or fumes.
– Do not install substitute parts or perform any
unauthorized modification to the device.
CAUTION
– Use the device with the cables provided.
– Repair or service that this not covered in this
manual should only be performed by qualified
personnels.
For further safety information details, refer to the
Keysight 82351B PCIe®-GPIB Interface User’s Guide.

4 Keysight 82351B Quick Start Poster
4 Keysight 82351B Quick Start Poster
Introduction
This Quick Start Guide provides a quick approach
for installing and configuring the 82351B
PCIe-GPIB interface card in your PC. For detailed
step-by-step installation and configuration
instructions, refer to Keysight 82351B PCIe- GPIB
Interface User’s Guide.
Product at a Glance
NOTE
Ensure the Keysight IO Libraries Suite software is
installed in your PC before installing the 82351B
PCle-GPIB interface card.

Keysight 82351B Quick Start Poster 5
Keysight 82351B Quick Start Poster 5
82351B General Information
82351B related documentation
See the following documents for information related
to the 82351B. All documents are available in
electronic format by clicking the IO icon on the
Windows® taskbar notification area and selecting
Documentation.
– Keysight IO Libraries Connectivity Guide
provides a description of the Keysight IO
Libraries and utilities, and detailed installation
information.
– Keysight IO Libraries Suite Online Help provides
detailed usage information on the Keysight IO
Libraries Suite utilities, including Connection
Expert.
– Keysight VISA User's Guide describes the
Keysight Virtual Instrument Software
Architecture (VISA) library.
– Keysight SICL User's Guide for Windows
describes the Keysight Standard Instrument
Control Library (SICL) for Windows.
Go to http://www.keysight.com/find/82351B for
additional information on the 82351B.

6 Keysight 82351B Quick Start Poster
6 Keysight 82351B Quick Start Poster
1 Before Installing the 82351B
Unpack and inspect the shipping container for
damage
Verify that you received the following items in your
shipment of the 82351B PCIe-GPIB Interface:
– Keysight 82351B PCIe-GPIB Interface Card
– Keysight Instrument Control DVD with Keysight
IO Libraries Suite
– Low Profile Bracket
– 82351B Quick Start Poster
If any items are missing or damaged, contact the
nearest Keysight Technologies or visit
www.keysight.com/find/assist for further
information.
82351B PCIe GPIB
Interface Card
Low Profile Bracket
Keysight Instrument
Control DVD
82351B Quick
Start Poster
NOTE
For Infiniium V-Series Oscilloscope:
Contact the nearest Keysight's service center or
visit http://www.keysight.com/my/faces/
fapHomePage to purchase a V-Series Profile
Bracket (54919-00105). The V-Series Profile
Bracket is a necessary additional part to upgrade
the 82351B PCIe-GPIB Interface Card.

Keysight 82351B Quick Start Poster 7
Keysight 82351B Quick Start Poster 7
2 Installing Keysight IO Libraries Suite
Insert the DVD
Turn on your PC and insert the Keysight Instrument
Control DVD with Keysight IO Libraries Suite into
the DVD drive. If the installer is not automatically
activated, click Start > Run and type
<drive>:autorun\auto.exe
Install the libraries
When the Keysight IO Libraries Suite window
appears, follow the on- screen instructions to install
the libraries. You do not need to run Keysight
Connection Expert at this time.
Look for IO icon
After the libraries are installed, the IO icon is
displayed on the Windows taskbar notification area.
You can click the icon to manually run I/O
configuration utilities and to display online
documentation. It is not necessary to use the icon at
this time.
NOTE
You may also install the Keysight IO Libraries Suite
v17.0 or above from the following web site:
www.keysight.com/find/iosuite

8 Keysight 82351B Quick Start Poster
8 Keysight 82351B Quick Start Poster
3 Installing the 82351B in Your PC
Record the card serial number
Remove the card from its anti- static bag and record
the serial number for future reference. Keep the
anti- static bag for storing purpose when you need
to remove the card from the PC.
Remove PC cover
Turn off power to the PC and to all of its peripherals.
Remove the power cord from the PC. Remove the
cover from the PC to allow access to the I/O slots.
See your PC documentation for instructions. Take
precautions against static discharge when handling
and installing cards.
Remove a cover plate
Remove one of the PC back panel cover plates and
fit the 82351B into any PCIe slot that will give
adequate clearance for the GPIB connector.

Keysight 82351B Quick Start Poster 9
Keysight 82351B Quick Start Poster 9
Install the 82351B
Insert the card’s edge connector into the PCIe
expansion slot connector of the PC. Ensure the
interface is fully seated by pushing firmly on the top
edge of the card with the palm of your hand. The
GPIB connector should extend through the back
panel opening to allow GPIB cable connection. Be
sure to hold the card by its edges. Also, be careful
with the metal faceplate around the GPIB connector
as the faceplate can be bent.
Replace the cover plate screw
This will hold the 82351B in place. Save the blank
cover plate for future use if the 82351B is later
removed. Replace the PC cover(s) as described in
your PC documentation.

10 Keysight 82351B Quick Start Poster
10 Keysight 82351B Quick Start Poster
4 Replace the standard profile bracket with
a low profile bracket or a V-Series Profile
Bracket (54919-00105)
Follow these steps if you use a PC chassis smaller
than a standard CPU chassis.
1Remove the hex screws that hold the connector
bracket and the standard profile bracket by
using a HEX 9/32”, Tightening torque: 7.0 IN/
LBS screwdriver.
2Replace the standard profile bracket with the
low profile bracket.
3Replace the standard profile bracket with the
V-Series Profile Bracket (54919-00105).
NOTE
Follow steps 1 and 3 if you use an Infiniium V-Series
Oscilloscope.
Tabla de contenidos
Otros manuales de Equipo de grabación de Keysight Technologies
Manuales populares de Equipo de grabación de otras marcas

Strymon
Strymon NIGHTSKY Manual de usuario

Mitsubishi Electric
Mitsubishi Electric 16CH DIGITAL RECORDER DX-TL5000U Manual de usuario

Tews Technologies
Tews Technologies TPMC465 Manual de usuario

Honeywell
Honeywell Excel 50 Manual de usuario

SeaLevel
SeaLevel COMM+8.LPCI Manual de usuario

Arturia
Arturia AUDIOFUSE STUDIO Manual de usuario















