Kantech INTEVO-CMP-1TB Manual de usuario

DN2055-1404
V 1.0
Access Control and Video Software Management
Intevo Compact (Model Intevo-CMP-1TB)
Intevo Advanced (Model Intevo-ADV-3TB)
Quick Setup Guide
Advanced and Compact models


1
Copyright
Under copyright laws, the contents of this manual may not be copied, photocopied,
reproduced, translated or reduced to any electronic medium or machine-readable form,
in whole or in part, without prior written consent of Tyco International Ltd.© 2012 and
its respective companies. All Rights Reserved.
Notice of Use
• Please read this manual carefully before use. All requirements should be followed before
using this server.
• We reserve the right to change the product and manuals without prior notice.
• Keep this document for future reference.
• The server is for indoor use only.
• Keep the server and other accessories in a dry environment.
• We are not responsible for any damage caused by inappropriate use.
• The Installer shall instruct the USER regarding ALL THE SAFETY INSTRUCTIONS that shall be
observed during the use of the equipment.
Warranty
• The server will be sold with a warranty period of 3 years starting the day of purchase by
the dealer / installer.
• The server manufacturer must offer this warranty as any defective unit will be returned to
them for replacement.
Important:
• This Intevo device shall be used and installed within an environment that provides the
pollution degree max. 2 and overvoltages category II NON HAZARDOUS LOCATIONS,
indoor only. The equipment is FIXED or DESKTOP and CORD CONNECTED and is designed
to be installed by service persons only; [a service person is defined as a person having the
appropriate technical training and experience necessary to be aware of hazards to which
that person may be exposed in performing a task and of measures to minimize the risks to
that person or other persons.]
• There is no ON/OFF SWITCH for the power supply. The AC power supply coupler serves as
a means of disconnection from the supply mains.
Safety Instructions
• Select a place that is free from vibration and shock.
• Do not locate this product where persons can walk on the cables.
• Do not connect the server to electrical outlets on the same circuit as large appliances.
• Do not select a place that exposes the server to direct sunlight, excessive heat, moisture,
vapors, chemicals or dust.
• Do not install this equipment near water (e.g., bathtub, wash bowl, kitchen/laundry sink,
wet basement, or near a swimming pool).
• Do not install this equipment and its accessories in areas where there is a risk of
explosion.
• Do not connect this server to electrical outlets controlled by switches or automatic timers.
• AVOID sources of radio interference.
• AVOID setting up the equipment near heaters, air conditioners, ventilators, and/or
refrigerators.
• Ensure that cables are positioned so that accidents can not occur. Connected cables must
not be subject to excessive mechanical strain.

2
• Use the included AC power supply and cord only.
Technical Specifications
• Operating Temperatures: 0°C to 40°C (32°F to 104°F) indoor use only.
• Humidity Level: 93% max. (relative humidity non-condensing).
• Cabinet Dimensions (Height-Width-Depth):
•Advanced: 6.4cm (2.52in) x 30cm (11.8in) x 28.9cm (11.38in).
•Compact: 5.4cm (2.25in) x 19cm (7.5in) x 21.5 cm (8.5in)
• Input: 100-240V, 50-60Hz, 2.0A.
• Output: 12V, 84W max.
This product contains a lithium battery that shall be
replaced only by an authorized service person. CAUTION:
Risk of explosion if battery is replaced by an incorrect
type. Dispose of used batteries according to the applicable
local legislation and instructions.

3
Quick Setup Guide
What Is In The Box?
• Intevo Unified Server
• Power cord
• Quick Setup Guide
• Wall mount brackets (2)
• Screws (6 for Advanced; 4 for Compact)
• USB Key (including: documentation, Configuration Tool, EntraPass
and IP video softwares).
Installation
Desktop Installation
Be very careful not to block the vents on the right side and on top
of the Intevo case. Avoid storing anything near the device that
could block air flow.
Wall Mount Installation (both models)
1- Fix the brackets on each side of the housing with the supplied
screws.
2- Fix to the wall the Intevo housing with the brackets provided using
four (4) screws (not included). We recommend stainless steel
Phillips tapping screws M4.2 x 32mm (#8 x 1.25'') (Spaenaur ST-
631P or equivalent). Drywall mounting must also use four (4)
plastic anchors (Spaenaur EX-S5 or equivalent; not included).

4
Rack Mount Installation (Not included; only for
Advanced model)
Precautions
• Elevated Operating Ambient - If installed in a closed or multi-unit
rack assembly, the operating ambient temperature of the rack
assembly may be greater than the room temperature. Therefore,
consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature
(Tma) specified by the manufacturer.
• Reduced Air Flow - Installation of the equipment in a rack should be
such that the amount of air flow required for safe operation of the
equipment is not compromised.
• Mechanical Loading - Mounting of the equipment in the rack should
be such that an hazardous condition is not achieved due to uneven
mechanical loading.
• Circuit Overloading - Consideration should be given to the
connection of the equipment to the supply circuit and the effect
that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this
concern.
• Reliable Earthing - Reliable earthing of rack-mounted equipment
should be maintained. Particular attention should be given to
supply connections other than direct connections to the branch
circuit (e.g. use of power strips).
Connections
Proceed with the following connections:
1- Connect your local network cable to ETH1.
2- Connect your camera network cable to ETH2.

5
3- Connect the monitor to VGA, DVI or HDMI port (for local access
only).
4- Connect a keyboard and a mouse to a USB port, on the back or the
front of the device (for local access only).
NOTE: DVI and HDMI ports cannot be used simultaneously.
NOTE: Intevo can be used without a monitor or mouse with a remote
access.
Compact front panel:
Compact back panel:

Number Port
1 Power button
2eSATA
3 Serial
4 DVI
5 VGA
6 HDMI
7 Ethernet 1
8 Ethernet 2
9 USB ports
10 Audio ports
6
Compact
Advanced front panel:

7
Advanced back panel:
Number Port
1 Power button
2 USB
3 Serial
4 DVI
5 VGA
6 HDMI
7 Ethernet 1
8 Ethernet 2
9 USB ports
10 Audio ports
Advanced

8
First Start Configuration
User Names and Passwords:
1- To log into the INTEVO unit, enter the following credentials:
Administrator:
User name: admin Password: admin
Operator:
User name: operator Password: (leave blank)
2- To log into the EntraPass software, enter the following credentials:
Installer:
User name: kantech Password: kantech
Administrator:
User name: kantech1 Password: kantech
Guard:
User name: kantech2 Password: kantech
Web access:
User name: intevo1 Password: intevo1
3- To log into the American Dynamics IP Video software (HDVR), enter
the following credentials:
Administrator:
User name: admin Password: admin256
Steps to follow for local access:
1- Power on the Intevo (done automatically when connecting the AC
power cable).
2- Follow the steps in the First Boot Wizard.
Steps to follow for remote access:
1- Power on the Intevo (done automatically when connecting the AC
power cable).
2- Insert the included USB key in the remote PC.
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Idiomas: