JUMO tecLine CR-4P Manual de usuario

JUMO tecLine CR-4P
Conductive 4-electrode conductivity sensor
Type 202930
B 202930.0
Operating Instructions
2012-04-05/00502496

WARNING:
Incorrect measurement values or failure of the instrument or a transmitter
connected to it, could potentially cause dangerous, imprecise dosing or a system
malfunction!
Suitable preventive measures to stop this happening must be in place.
Note:
Please read these operating instructions before commissioning the instrument.
Keep the manual in a place which is accessible to all users at all times.
If any difficulties should arise during startup, please do not tamper with the
instrument in any way. By doing so, you could endanger your rights under the
instrument warranty! Please contact your supplier.

Contents
1 Typographical conventions ...................................................... 5
1.1 Warning signs ..............................................................................................5
1.2 Reference signs ...........................................................................................5
2 Description ................................................................................ 6
3 Instrument identification .......................................................... 8
3.1 Nameplate ....................................................................................................8
3.2 Type description ..........................................................................................8
3.3 Accessories ..................................................................................................9
4 Mounting .................................................................................. 10
4.1 General .......................................................................................................10
4.2 JUMO PEKA process connection adapter .................................................11
4.3 Mounting suggestions ................................................................................11
5 Installation ............................................................................... 15
5.1 Electrical connection ..................................................................................15
5.2 Terminal assignment and wiring colors .....................................................15
5.3 CR-4P cable ...............................................................................................16
5.4 Connection example ..................................................................................17
6 Calibration ............................................................................... 19
6.1 Notes ..........................................................................................................19
6.2 General .......................................................................................................19
6.3 JUMO AQUIS 500 CR settings ..................................................................19
7 Maintenance/troubleshooting ............................................... 20
7.1 Cleaning the conductivity sensor ...............................................................20
7.2 Troubleshooting .........................................................................................21
8 Technical data ......................................................................... 22


5
1 Typographical conventions
1.1 Warning signs
1.2 Reference signs
Danger
This symbol is used when there may be danger to personnel if the
instructions are ignored or not followed correctly!
Caution
This symbol is used when there may be damage to equipment or data if the
instructions are ignored or not followed correctly!
Note
This symbol is used to draw your special attention to a remark.
abc1Footnote
Footnotes are remarks that refer to specific points in the text. Footnotes
consist of two parts:
A marker in the text and the footnote text.
The markers in the text are arranged as consecutive superscript numbers.
✱Action instruction
This symbol indicates that an action to be performed is described.
The individual steps are marked by this asterisk.
Example:
✱Connect the cable.

6
2 Description
General
Conductive conductivity sensors are used in conjunction with suitable
transmitters in industrial analysis measurement technology to determine the
electrolytic conductivity of liquids.
The JUMO tecLine CR-4P fills the gap between conductive conductivity
measurement with two-electrode measuring sensors, and inductive
conductivity measurement.
Four-pin technology makes it possible to cover a very wide measuring range
from about 1 µS/cm to 600 mS/cm, with just one measuring sensor.
The hygienic design of the sensor and the EHEDG-certified system for process
connection (JUMO PEKA), mean that it can be used in pharmaceutical and
food technology without difficulty. JUMO PEKA is an adapter system that
combines the measuring sensor with the process connection. All the materials
are physiologically safe, and meet FDA standards.
Stainless steel electrodes are inserted into a circular, plastic body. The process
seal provided as standard is an EPDM O-ring. A fast-response temperature
probe delivers information about the process temperature to the measurement
amplifier. Electrical connection is made via an M12 connector.
The measuring sensor is available in three fitting lengths, for optimum
installation in different pipe diameters. The measuring sensor can also be
installed in container walls. No incident flow is required to make it work, but is
recommended for fast, stable measurement values and to prevent the
accumulation of deposits.
A certificate of quality is included among the items supplied (exact cell
constant, FDA approval for the material, typical surface roughness, etc.).
Operative range
Their vast measuring range of 1 µS/cm to 600 mS/cm, allows the sensors to
be used in washing processes in food and drink applications, pharmaceuticals
and biotechnology, where the different conductivities have to be safely
recorded by a measuring system (e.g. CIP/SIP applications, reverse processes
in ion exchangers, phase separation, bottle cleaning plants, process water).
Note
Used in combination with the JUMO AQUIS 500 CR transmitter/controller, as
per data sheet 202565 and JUMO PEKA process connection adapters as per
data sheet 409711.
Key features
• Vast measuring range
• EHEDG-certified process connections (clamp, Varivent®, aseptic NKS)
• CIP/SIP capability
• Design complies with EHEDG and FDA standards
• Certificate of quality included

7
2 Description
Function
The measuring sensors have two pairs of electrodes. The transmitter applies
alternating current at the outer pair of electrodes. A voltage is released at the
inner electrodes - subject to the conductivity of the measuring material. The
transmitter acquires the voltage and uses it to calculate the electrolytic
conductivity value. Functionally, excitation and measurement are kept
separate. This has some advantages compared to 2-electrode measuring
sensors, as the effects of polarization recede into the background. To a large
extent, incoming resistances are automatically compensated. Measurement
errors as a result of contamination or deposits, are reduced.
Measuring sensors
voltage/current
voltage
current/voltage
control
voltage measurement
(1) (4)
(2) (3)
Description M12 connector pin
(1) Current supply, outer electrode 1 6
(2) Voltage tap, inner electrode 1 7
(3) Voltage tap, inner electrode 2 3
(4) Current supply, outer electrode 2 4
(5) Pt1000 temperature probe 1, 2 and 5
(2) (3)
(4)
(4)
(1)
(4)
(1)
(1)
(5)

8
3 Instrument identification
3.1 Nameplate
On the measuring sensor
3.2 Type description
The date of manufacture is encoded in "F-Nr." (serial number):
0942 means year of manufacture 2009/calendar week 42.
JUMO GmbH & Co. KG
Fulda, Germany www.jumo.net
Typ: 202930/10-1005-997-83/000
VARTN: 20/00123456
F-Nr.: 01234567 01 0 0942 0002
Cell M: 0,30 1/cm
(1) Basic type
202930 JUMO tecLine CR-4P
Conductive 4-electrode conductivity sensor
(2) Basic type extension
10 Short design
20 Medium design
30 Long design
(3) Temperature compensation
1005 Pt1000
(4) Electrode material
31 Stainless steel 1.4435 (316L)
(5) Process connection1
1Process connection adadpters (see "Accessories") must be ordered separa-
tely.
997 JUMO PEKA
(6) Electrical connection2
2The CR-4P cable is required for electrical connection (see "Accessories")!
83 M12 connector
(7) Extra codes
000 none
(1) (2) (3) (4) (5) (6) (7)
Order code /- ---/
Sample order 202930 / 10 - 1005 - 31 - 997 - 83 / 000

9
3 Instrument identification
3.3 Accessories
Designation Sales No.
CR-4P cable, 5 m, made up, with M12 connector 00528699
CR-4P cable, 10 m, made up, with M12 connector 00528700
JUMO PEKA process
connection adapter for Material Sales No.
Varivent DN 40-125 Stainless steel 1.4435/316L 00445046
Varivent DN 40-125 Stainless steel 1.4435/316L;
Ra < 0,8 µ
with certificate EN 10204-3.1
00577961
Clamp DN 25/32/40 Stainless steel 1.4435/316L 00445047
Clamp DN25/32/40 Stainless steel 1.4435/316L;
Ra < 0,8 µ
with certificate EN 10204-3.1
00577998
Clamp DN 50 Stainless steel 1.4435/316L 00445037
Clamp DN 50 Stainless steel 1.4435/316L;
Ra < 0,8 µ
with certificate EN 10204-3.1
00577997
Aseptic DN 40 Stainless steel 1.4435/316L 00446458
Aseptic DN 40 Stainless steel 1.4435/316L;
Ra < 0,8 µ
with certificate EN 10204-3.1
00577995
Aseptic DN 50 Stainless steel 1.4435/316L 00445035
Aseptic DN 50 Stainless steel 1.4435/316L;
Ra < 0,8 µ
with certificate EN 10204-3.1
00577979
Aseptic NKS DN 40 Stainless steel 1.4435/316L 00447555
Aseptic NKS DN 40 Stainless steel 1.4435/316L;
Ra < 0,8 µ
with certificate EN 10204-3.1
00577999

10
4 Mounting
4.1 General
Mounting location
Find a location that ensures easy accessibility for the later calibration.
The fastening must be secure and must ensure low vibration for the instrument.
The operating conditions (temperature, pressure, chemical composition of the
measuring material, etc.,) must not be allowed to damage the measuring sensor.
The measuring sensor must not be modified mechanically (e.g. shortened,
drilled, ground).
A minimum distance of at least two meters must be maintained when
installing several JUMO tecLine CR-4P type conductivity sensors.
Installation position
The conductivity sensor can be mounted in any position. But it is essential to
make sure that the measuring sensor electrodes are fully immersed in the
measuring material.
Incident flow
No incident flow is required to make the conductivity sensor work, but is
recommended for fast, stable measurement values and to prevent the
accumulation of deposits. Structural measures must be taken to prevent flow
separation or gas bubbles in the measuring material.
Immersion length
The immersion length (EL) of the conductivity sensor must be in keeping with
the installation situation.
(1) Width across flats 27
(2) JUMO PEKA process connection
A suitable process connection adapter is an essential requirement of
installation, see below.
(3) 21 × 2.5 O-ring (EPDM)
Immersion length EL Total length GL Type
18 126 202930/10
38 146 202930/20
48 156 202930/30
M28x1.5
ø22.5
GL
EL
(1)
(2)
(3)
Tabla de contenidos
Otros manuales de Accesorios de JUMO

JUMO
JUMO MAERA S29 SW Manual de usuario

JUMO
JUMO digiLine O-DO S10 Manual de usuario

JUMO
JUMO tecLine Series Manual de usuario

JUMO
JUMO 902454/10 Manual de usuario

JUMO
JUMO digiLine CR Series Manual de usuario

JUMO
JUMO tecLine ClO2 Manual de usuario

JUMO
JUMO tecLine ClO2 Manual de usuario

JUMO
JUMO 201040 Manual de usuario

JUMO
JUMO BlackLine CR 4P Manual de usuario