Important Safety Instructions
JP5535 True Online 1-3K UPS User Manual
I
Important Safety Instructions
Save these instructions
This manual contains important safety instructions. Read all safety and operating instructions
before operating the uninterruptible power systems (UPS). Adhere to all warnings on the unit
and in this manual. Follow all operating and user instructions. This equipment can be operated
by individuals without previous training.
Maximum load must not exceed that shown on the UPS rating label. The UPS is designed for
data processing equipment. If uncertain, consult your dealer or local representative.
The 1-3kVA@200/208/220/230/240VAC is designed for use with a three-wire input (L,N,G).
WARNING
The battery can present a risk of electrical shock and high
short circuit current. Following precautions should be
observed before replacing the battery.
Wear rubber gloves and boots.
Remove rings, watches and other metal objects.
Use tools with insulated handles.
Do not lay tools or other metal objects on the batteries.
If the battery is damaged in any way or shows signs of leakage, contact your local
representative immediately.
Do not dispose of batteries in a fire. The batteries may explode.
Handle, transport and recycle batteries in accordance with local representative.
WARNING
Although the UPS has been designed and manufactured to
ensure personal safety, improper use can result in electrical
shock or fire. To ensure safety, observe the following
precautions:
Turn off and unplug the UPS before cleaning it.
Clean the UPS with a dry cloth. Do not use liquid or aerosol cleaners.
Never block or insert any objects into the ventilation holes or other openings of the UPS.
Do not place the UPS power cord where it might be damaged.

Contents
II JP5535 True Online 1-3K UPS User Manual
CONTENTS
1.Electromagnetic Compatibility ............................................................................................... 1
2. Introduction .......................................................................................................................... 2
3. System Description .............................................................................................................. 5
3.1 Transient Voltage Surge Suppression (TVSS) and EMI/FRI Filters ............................... 5
3.2 Rectifier/Power Factor Correction (PFC) Circuit............................................................ 5
3.3 Inverter ......................................................................................................................... 5
3.4 Battery Charger ............................................................................................................ 5
3.5 DC-to-DC Converter ..................................................................................................... 6
3.6 Battery .......................................................................................................................... 6
3.7 Dynamic Bypass........................................................................................................... 6
4. Product Specification and performance ............................................................................... 7
4.1 Model Description ......................................................................................................... 7
4.2 Product Specification and Performance ........................................................................ 7
5. Installation ........................................................................................................................... 7
5.1 Unpacking and Inspection ............................................................................................ 9
5.2 Connect Input/Output Power ........................................................................................ 9
5.3 Operating procedure for connecting the long backup time model UPS with the external
battery .............................................................................................................................. 10
6. Controls and Indicators ...................................................................................................... 12
7. Operation........................................................................................................................... 15
7.1 Operation Mode.......................................................................................................... 15
8. Battery maintenance .......................................................................................................... 16
9. Notes for battery disposal and replacement procedures .................................................... 17
9.1 Battery Disposal ......................................................................................................... 17

Contents
JP5535 True Online 1-3K UPS User Manual
III
9.2 Battery Replacement Procedures ............................................................................... 17
10. Trouble shooting .............................................................................................................. 18
10.1 Checking UPS status ................................................................................................ 18
10.2 Adjust the factors caused the problem ...................................................................... 18
Annex A. Intelligent Slot ......................................................................................................... 22
Annex B. EPO ....................................................................................................................... 23
Annex C. Rated Parameters Setting ...................................................................................... 24


Electromagnetic Compatibility
JP5535 True Online 1-3K UPS User Manual
1
1.Electromagnetic Compatibility
* Safety
IEC/EN 62040-1-1
* EMI
Conducted Emission.........IEC/EN 62040-2 Class A
Radiated Emission............IEC/EN 62040-2 Class A
*EMS
ESD..................................IEC/EN 61000-4-2
Level 4
RS....................................IEC/EN 61000-4-3
Level 3
EFT..................................IEC/EN 61000-4-4 Level 4
SURGE............................IEC/EN 61000-4-5 Level 4
Low Frequency Signals..............:IEC/EN 61000-2-2
Warning: This is a product for commercial and industrial application in the second
environment-installation restrictions or additional measures may be needed to
prevent disturbances.
NOTICE:
This is a product for restricted sales distribution to informed partners. Installation restrictions or
additional measures may be needed to prevent radio interference.
Operated the UPS in an indoor enviroment only in an ambient temperature range of 0-
40C(32-104F). Install it in a clean environment, free from moisture, flammable liquids, gases
and corrosive substance.
This UPS contains no user-serviceable parts except the internal battery pack. The UPS on/off
push buttons do not electrically isolate internal parts. Under no circumstance attempt to gain
access internally, due to the risk of electric shock or burn.
Do not continue to use the UPS if the panel indications are not in accordance with these
operating instructions or the UPS performance alters in use. Refer all fault to your dealer.
Servicing of batteries should be performed or supervised by personnel knowledgeable of
batteries and the precautions. Keep unauthorized personnel away from the batteries. Proper
disposal of batteries is required. Refer to your local laws and regulations for disposal
requirement.
DO NOT CONNECT equipment that could overload the UPS or demand DC current from the
UPS, for example: electric drills, vacuum cleaners, laser printers, hair dryer or any appliance
using half-wave rectification.
Storing magnetic media on top of the UPS may result in data loss or corruption.
Turn off and isolate the UPS before cleaning it. Use only a soft cloth, never liquid or aerosol
cleaners.

Introduction
2 JP5535 True Online 1-3K UPS User Manual
2. Introduction
Congratulations on your choice of the uninterruptible power system(UPS), the UPS comes in
nominal power ratings of 1000VA,2000VA and 3000VA. It is designed to provide conditioned
power to microcomputers and other sensitive electronic equipment.
When it is generated, alternating current is clean and stable. However, during transmission
and distribution it may be subject to voltage sags, spikes and complete power failure that may
interrupt computer operations, cause data loss and even damage equipment. The UPS
protects equipment from these disturbances.
The UPS is a compact, on-line UPS. An on-line UPS continuously conditions and regulates its
output voltage, whether utility power is present or not. It supplies connected equipment with
clean sinewave power. Sensitive electronic equipment operates best from sinewave power.
For ease of use, the UPS features a LCD display to indicate all information for UPS, and
provide kinds of function buttons.
1KVA 2KVA/3KVA
Fig 1. Front View

Introduction
JP5535 True Online 1-3K UPS User Manual
3
1 32
4 7
5
8
9
6
10
1 2 3
4
7
8
5
6
9
10
1KVA 2KVA
1 2 3
4
5
6
7
8
9
1 2 3
4
5
6
7
8
11
10
9
3KVA
Fig 2. Rear View
RS-232 communication port. DB9 type.
EPO. Short to activate.
Intelligent slot
USB port. B type.
Input surge protection slot.
Input socket. 1KVA: IEC C14, 2K/3K: IEC C20

Introduction
4 JP5535 True Online 1-3K UPS User Manual
Network surge protection.
Output Socket
External battery port. Optional for standard model.
10
Battery ground
11
Output terminal

System Description
JP5535 True Online 1-3K UPS User Manual
5
3. System Description
3.1 Transient Voltage Surge Suppression (TVSS) and EMI/FRI Filters
These UPS components provide surge protection and filter both electromagnetic interference
(EMI) and radio frequency interference (RFI). They minimize any surge or interference present
in the utility line and keep the sensitive equipment protected.
3.2 Rectifier/Power Factor Correction (PFC) Circuit
In normal operation, the rectifier/power factor correction (PFC) circuit converts utility AC power
to regulated DC power for use by the inverter while ensuring that the waveform of the input
current used by the UPS is near ideal. Extracting this sinewave input current achieves two
objects:
The utility power is used as efficiency as possible by the UPS.
The amount of distortion reflected on the utility is reduced.
This results in cleaner power being available to other devices in the building not being
protected by the UPS.
3.3 Inverter
In normal operation, the inverter utilize the DC output of the power factor correction circuit and
inverters it into precise, regulated sinewave AC power. Upon a utility power failure, the inverter
receives its required energy from the battery through the DC-to-DC converter. In both modes
of operation, the UPS inverter is on-line and continuously generating clean, precise, regulated
AC output power.
3.4 Battery Charger
The battery charger utilizes energy from the utility power and precisely regulates it to
continuously float charge the batteries. The batteries are being charged whenever the UPS is
Tabla de contenidos
Otros manuales de Unión Postal Universal de JALpower

JALpower
JALpower JP5530 Series Manual de usuario

JALpower
JALpower JP5520 Manual de usuario

JALpower
JALpower JP 3325 Series Manual de usuario

JALpower
JALpower JP9950 Manual de usuario

JALpower
JALpower JP5530 Series Manual de usuario

JALpower
JALpower JP9950 Manual de usuario

JALpower
JALpower JP9960 Manual de usuario
Manuales populares de Unión Postal Universal de otras marcas

Pylontech
Pylontech Victron & Pylontech US5000 Manual de usuario

Tecnoware
Tecnoware EVO DSP PLUS MM 6.8 Manual de usuario

Mecer
Mecer ME-1000-WTU Manual de usuario

Mustek
Mustek PowerMust 530(B) Plus Manual de instalación y operación

Emerson
Emerson Liebert NXL series Manual de usuario

MAKELSAN
MAKELSAN BOXER SERIES Manual de usuario