Jadever JWI600 Manual de usuario

CONTENTS
Part
I
Preparations before Usage
1-1. Precautions before Usage………………………
1-2. Specifications and Characteristics…
2
2
Part
II
Product Introduction & Installation
2-1. Main Functions Introductions……………….……
2-2.Connection Between Display and Load Cell ……….…
2-3.Keypad Function and Panel Indication……………
3
4
5
Part
III
Setting of Weighing Capacity & Accuracy
3-1.Setting Operation……………………….…………
3-2.Relation Between LOAD-CELL Output & Input
Sensitivity……
7
9
Part
IV
Setting of Functional Parameters
4-1.Enter into Parameter Setting…………….…………
4-2.Description of Functional Parameters.…………
10
11
PAGE
JADEVER
http:www.jadever.com.tw
0

Part
V
Functional Operation
5-1.Zero…………………………………
5-2.Manual Tare…………….………….…….…
5-3.Pre-tare…………………………….………….…….…
5-4.Automatic Tare…………….………….…….…
5-5.Unit Shifting…………………….………………
5-6.Accumulation, Accumulation Display &
Accumulation Clearing……
5-7.Simple Counting & Percentage Calculation…
5-8.Weight-checking……………….………….…….…
16
16
17
18
20
20
21
22
Part
VI
Single Point Weight Calibration…………………………..
23
Part
VII
Error Message & Simple Troubleshooting ……………… 24
Part
VIII
External Interface
8-1. RS-232+RTC board output pin….……
8-2. Option Output
8-2-1. Printer Output.…………………………..
8-2-2. PC Output.……………………………………
8-3. RS-232 Output Format…………………………
8-4. RS-232 Input Format………………………..
25
26
27
21
29
33
34
34
35
35
Part
XI
Appendix
1. Installation of Upright Pole………………………….
2. Unit Conversion Table……………………….……………
3. Optional Accessories…………………………………
36
37
37
PAGE
JADEVER
http:www.jadever.com.tw
1

Part I Preparations before Usage
1-1. Precautions before Usage
◎Please charge the battery before using for the first time.
Charging instruction: when the battery symbol appears on the upper left of the screen, it
indicates that the power nearly runs out. Please recharge as soon as possible. Once
the indicator turns green from red, it indicates that the recharging is completed, which
takes about 8 hours. Avoid using before recharging is completed.
◎Be sure to select proper power supply before using, where a separate power outlet will
help avoid being interfered.
Select a flat and ◎stable installation site.
◎Avoid an operation environment where the scale will be exposed to strong wind,
vibration and electromagnetic wave. (e.g. air inlet of air conditioner or fan, or near heavy-duty
machines).
Please select an environment where the temperature is maintained within 0◎℃~ 40 , ℃
avoid drastic temperature change.
15◎-minute preheating is required before usage.
Please select 110~240 VAC±10% 50/60HZ,6V4Ah BATTERY. Improper battery or ※
connection may cause system damage or other adverse effects.
1-2. Specifications and Characteristics
Model JWI600
Input Sensitivity 0.13uV/DIV
Input Voltage Range -0.5mV to 16.5mV
Supply Voltage of Load
Cell
5V DC ±5%
Driving Capacity of Load
Cell
Up to 8 untis of load cell at 350 ohm (120mA)
Non-linearity 0.006% of full capacity
PAGE
JADEVER
http:www.jadever.com.tw
2

A/D Input Impedance 5Mohm or more
A/D Conversion Mode △-Σ
A/D Internal Resolution 700000 count
A
/D Conversion Output
Cycle
8 times/sec
External Display
Resolution
15000 count
Digit of LCD 6 digit
Number of Key Setting, Printing, GW/NW, Tare, Zeroing, On/Off
Specification of Power
Supply
110V or 220V & 6V 4A Recharge BAT.
Part II Product Introduction & Installation
2-1 Main Functions Introductions
The series is a weight display device that can output the value of weight via Load
Cell (weight sensor) and display it in digit number through A/D conversion. Its main
features include:
1) Microcomputer processing provides functions as follows:
a. Automatic adjustment of zero point.
b. Zero point tracking startup and close function selection.
c. It is allowed to select and set sampling filter speed depending on different
application conditions.
d. Weight-checking function, it will give sound alarm once the required package
quantity is reached.
e. Tare
f. Pre-tare
g. Automatic tare
h. Automatic zeroing.
i. Weight accumulation
2) Touch key with good feel enables easy operation. Dust cover ensures nice look.
3) HTN-LCD display with backlight realizes clear and readable caption display.
4) It can be used for simple counting.
5) The tare range should be full stage taring.
6) Optional bilateral RS-232 or weight-checking signal output module.
7) Both AC power and rechargeable battery are allowed. Built-in battery checking
system can automatically find whether it requires recharging.
8) Fast display, stable, accurate and easy operation.
2-2.Connection Between Display and Load Cell
PAGE
JADEVER
http:www.jadever.com.tw
3

CONN
1
2
3
4
5
E+
E-
S+
S-
LOAD-CELL
Shield
PIN SIGNAL
1 E+
2 E-
3 S+
4 S-
LOAD CELL
CONNECTION
5 SHIELD
Solution to overlarge LOAD-CELL output:
Solution to oversmall LOAD-CELL output:
50k~500k ohm
Add resistance
LOAD-CELL
S
S+
E
E+
-
-
Add resistance
S+
E+
E-
S-
LOAD-CELL
50k~500k ohm
PAGE
JADEVER
http:www.jadever.com.tw
4

2-3 Keypad Function and Panel Indication
LCD Display
LCD Display Display Description
Gross weight symbol
auxiliary unit
% Unit for simple counting and percentage
kg unit
Indicates steady usage.
M+ Accumulation symbol.
Negative symbol
NET Net weight symbol
ZERO Zeroing symbol
Low battery power indication.
upper limit, OK and lower limit weight-checking
mode
PAGE
JADEVER
http:www.jadever.com.tw
5

Description of Keys:
Name Operation Mode Function
Power on/off
Zero
Tare
gross/net weight shift
manual print
function shift, enter into
weight-checking value
setting
unit shift
Pre-tare
Accumulate
Accumulation display
Accumulation clearing
:digit plus 1 : digit displacement
:Function selection : enter into setting mode
:exit setting mode
:indicates press down the key once
Part III Setting of Weighing Capacity & Accuracy
PAGE
JADEVER
http:www.jadever.com.tw
6

3-1. Setting Operation
Step Description Screen display
1 Press and hold down the key
and
press the
key , then release the
key to enter into what
shown at the right figure,
lastly release the key
.
2
Press the key to enter
into setting of maximum
weighing capacity.
Press the key to
cyclically select the weighing
capacity. After selection, it is
allowed to begin step 4
directly or freely set the
weighing capacity according
to the following operation.
……
Press the key till the
screen displays the right
figure.
Press the key , as
shown at the right figure, the
last zero is flashing; it is time
to freely set the weighing
capacity.
3
Press the key : the
flashing digit moves left.
PAGE
JADEVER
http:www.jadever.com.tw
7

Press the key : the
flashing digit figure is
increased.
4
Press the key to enter
into minimum scale
(accuracy) setting mode.
5
Press the key to
cyclically select the accuracy
[1,2,5,10,20,50]
……
6
Press the key to enter
into decimals position
cyclical setting mode.
7
Press the key to
cyclically set the position of
decimals.
……
8 After setting, press the
key
.
9
Press the key
Max. weighing
capacity Resolution
Max 1 min. scale 2 min. scale 5 min. scale 10 min. scale 20 min. scale 50 min. scale
300 1⁄300 ------------ ------------ ------------ ------------ ------------
400 1⁄400 ------------ ------------ ------------ ------------ ------------
500 1⁄500 ------------ ------------ ------------ ------------ ------------
600 1⁄600 1⁄300 ------------ ------------ ------------ ------------
800 1⁄800 1⁄400 ------------ ------------ ------------ ------------
1,000 1⁄1000 1⁄500 ------------ ------------ ------------ ------------
1,200 1⁄1200 1⁄600 ------------ ------------ ------------ ------------
1,500 1⁄1500 1⁄800 1⁄300 ------------ ------------ ------------
2,000 1⁄2000 1⁄1000 1⁄400 ------------ ------------ ------------
2,500 1⁄2500 1⁄1250 1⁄500 ------------ ------------ ------------
3,000 1⁄3000 1⁄1500 1⁄600 1⁄300 ------------ ------------
4,000 1⁄4000 1⁄2000 1⁄800 1⁄400 ------------ ------------
5,000 1⁄5000 1⁄2500 1⁄1000 1⁄500 ------------ ------------
6,000 1⁄6000 1⁄3000 1⁄1200 1⁄600 1⁄300 ------------
8,000 1⁄8000 1⁄4000 1⁄1600 1⁄800 1⁄400 ------------
10,000 1⁄10000 1⁄5000 1⁄2000 1⁄1000 1⁄500 ------------
12,000 1⁄12000 1⁄6000 1⁄2400 1⁄1200 1⁄600 ------------
15,000 1⁄15000 1⁄7500 1⁄3000 1⁄1500 1⁄750 1⁄300
20,000 ------------ 1⁄10000 1⁄4000 1⁄2000 1⁄1000 1⁄400
25,000 ------------ 1⁄12500 1⁄5000 1⁄2500 1⁄1250 1⁄500
30,000 ------------ 1⁄15000 1⁄6000 1⁄3000 1⁄1500 1⁄600
40,000 ------------ ------------ 1⁄8000 1⁄4000 1⁄2000 1⁄800
50,000 ------------ ------------ 1⁄10000 1⁄5000 1⁄2500 1⁄1000
PAGE
JADEVER
http:www.jadever.com.tw
8

60,000 ------------ ------------ 1⁄12000 1⁄6000 1⁄3000 1⁄1200
75,000 ------------ ------------ 1⁄15000 1⁄7500 1⁄3750 1⁄1500
80,000 ------------ ------------ ------------ 1⁄8000 1⁄4000 1⁄1600
100,000 ------------ ------------ ------------ 1⁄10000 1⁄5000 1⁄2000
120,000 ------------ ------------ ------------ 1⁄12000 1⁄6000 1⁄2400
150,000 ------------ ------------ ------------ 1⁄15000 1⁄7500 1⁄3000
200,000 ------------ ------------ ------------ ------------ 1⁄10000 1⁄4000
250,000 ------------ ------------ ------------ ------------ 1⁄12500 1⁄5000
300,000 ------------ ------------ ------------ ------------ 1⁄15000 1⁄6000
400,000 ------------ ------------ ------------ ------------ ------------ 1⁄8000
500,000 ------------ ------------ ------------ ------------ ------------ 1⁄10000
600,000 ------------ ------------ ------------ ------------ ------------ 1⁄12000
700,000 ------------ ------------ ------------ ------------ ------------ 1⁄14000
750,000 ------------ ------------ ------------ ------------ ------------ 1⁄15000
3-2 Relation between LOAD-CELL Output & Input Sensitivity
If the input accuracy of JWI600 display is higher than 0.13uv/D, it indicates that
every one scale the accuracy changes, the required output voltage of load cell shall
be more than 0.13uv/D. For the platform design, the output voltage of LOAD-CELL
must match with the input accuracy of weight display unit, so the final design must
conform to the following formats. The accuracy should be as large as possible so as
to ensure stable performance of platform.
Using one LOAD-CELL:
Format: 0.13≦【 (5000 ×B ×D)÷A 】
A: Rated load of LOAD-CELL (CAP.) B: Rated output of LOAD-CELL (mV/V)
D:Minimum scale
N: Quantity of LOAD-CELL
5000: Voltage of LOAD-CELL supplied by
the display unit
5V=5000mV
For lever LOAD-CELL, lever ratio should be taken into consideration.
Using N LOAD-CELLs:
Format: 0.13≦【 (5000 ×B ×D)÷(A×N) 】
A: Rated load of LOAD-CELL (CAP.) B: Rated output of LOAD-CELL (mV/V)
D: Minimum scale
N: Quantity of LOAD-CELL
5000: Voltage of LOAD-CELL supplied by
the display unit
5V=5000mV
For lever LOAD-CELL, lever ratio should be taken into consideration.
Example
The rated load of Load-cell is 750kg and the rated output is 3mV/v.
The requirement of platform scale: maximum weighing capacity is 300kg an
d
minimum accuracy is 0.05kg.
PAGE
JADEVER
http:www.jadever.com.tw
9
Tabla de contenidos
Manuales populares de Equipo de prueba de otras marcas

SMART
SMART KANAAD SBT XTREME 3G Series Manual de usuario

Agilent Technologies
Agilent Technologies BERT Serial Manual de usuario

Agilent Technologies
Agilent Technologies N3280A Manual de usuario

Vernier
Vernier Go Direct Voltage Manual de usuario

Lifeloc
Lifeloc R.A.D.A.R. Manual de usuario

Fluke
Fluke T5-600 Instrucciones de funcionamiento e instalación