IVRA BTS c-Go Manual de usuario

1
BTS
Battery Test System
2/4 Channel
Instruction manual
GB

English
2
Index
1. Product description......................................................................................................................... 3
2. Safety instructions........................................................................................................................... 4
3. Product overview ............................................................................................................................ 5
4. BTS power on................................................................................................................................... 6
5. Language selection.......................................................................................................................... 6
6. Battery test...................................................................................................................................... 8
6.1. Connect battery....................................................................................................................... 8
6.2. Steps to start a battery test..................................................................................................... 8
7. Charger test................................................................................................................................... 14
7.1. Connect charger .................................................................................................................... 14
7.2. Steps to start a charger test .................................................................................................. 14
8. BTS - PC connection....................................................................................................................... 15
9. BTS advanced................................................................................................................................. 15
10. Troubleshooting ............................................................................................................................ 16
11. Specifications................................................................................................................................. 18

English
3
1. Product description
The c-Go Battery Test System from IVRA Electronics will make 12V and 24V battery testing and/or
reconditioning easy and efficient. Normal battery testing will be easy using our intuitive menu and 7”
touchscreen. Connect the batteries and temperature sensor, set the right testing parameters and
press start is all you have to do. The Battery Test system will test lead-acid(Gel /AGM) and lithium ion
batteries and show a detailed report on the 7” touchscreen when the test is finished. An option is to
write the result to a flash drive. Another feature of the battery test system is testing 12V and 24V
chargers.
Potential applications
-Battery quality control
-Reconditioning batteries
-Checking batteries so they can be redeployed
The BTS consists of:
1. A high quality metal powder coated housing.
2. A 7 inch touch display.
3. Two or four battery test channels.
4. Up to three built in chargers (12V or 24V or 12V-24V combination).
5. One built in discharge module.
6. Two or four SB50 to Crocodile clamps battery test leads.
7. Two or four temperature sensors with 3.5mm jack cable.
8. One power cord IEC-C13.
9. SB50 to XLR charger test lead.
10. USB –3.5mm jack serial cable.

English
4
Symbols:
You must obey the safety instructions.
Read the user instruction before use
For indoor use only
Do not use in a damp environment or in rain.
Do not dispose of the BTS as household garbage.
In order to save the environment it must be disposed of with care in
accordance with local regulations.
The BTS meets the CE requirements valid in Europe.
2. Safety instructions
-Do not charge the Li-ion battery at temperatures below 0°C. First transport the Li-ion battery
and the BTS to a location where the temperature is higher and then start the test/charging
procedure.
-Charge specified batteries only. Do not recharge non-rechargeable batteries.
-Charge the batteries only if there is proper ventilation. Especially around the batteries. While
charging, a small amount of explosive gasses can be generated in the batteries.
inadequate ventilation in combination with open fire or sparks can lead to dangerous situations.
-Do not connect or disconnect the battery while the BTS is testing the battery. E.g. to reduce risk
of sparking.
-Batteries are capable of providing a lot of energy in a short time span. Prevent short circuits in
any way. For example walking over the cables or damaging the cables or connector by improper
use.
-Only use cables supplied with the BTS.
-Do not use the BTS if the cables are damaged.
-If the power cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard. If the BTS is defective, do not try to repair
it.
-The BTS should never be used in a very damp or wet environment (for instance outdoors), never
poor fluids over it or submerge it in water.
-The system must not be exposed to chemical substances or vapours.
-Make sure the BTS is positioned stable.
-Keep a free zone of 20cm around the BTS to ensure that heat, generated during operation, can
be removed.
-Do not place the BTS in direct sunlight.
-Do no place the BTS in an environment that contains mechanical vibrations(i.e. Compressors,
etc.) or where a lot of heat is generated(Heaters, Ovens, etc.).
-The ventilation slots of the BTS have to be kept free of excessive dust built up.
-Make sure the BTS is connected to an appropriately earthed wall outlet.

English
5
3. Product overview
Overview inputs/outputs battery test system
BTS Type
4-channel
2-channel
7“ touchscreen
Battery input channel 1
----
Temperature sensor input channel 1
----
Battery input channel 2
Battery input channel 1
Temperature sensor input channel 2
Temperature sensor input channel 1
Battery input channel 3
Battery input channel 2
Temperature sensor input channel 3
Temperature sensor input channel 2
Battery input channel 4
----
USB (for flash drive)
Temperature sensor input channel 4
----
Mains power entry connector including fuse holder
3.5mm jack serial input connector

English
6
4. BTS power on
Power on battery test system using the power switch on the power entry connector after the power
cord is connected.
Connect all battery cables to the inputs and the temperature sensor cables to the temperature
sensor inputs.
5. Language selection
The BTS supports the languages English, Nederlands, Deutsch.
To select a language, press “Hardware overview”

English
7
In the next screen press “Language”
In the next screen choose the required language:

English
8
6. Battery test
6.1. Connect battery
Mount the battery sensor to the minus pole and connect the crocodile clamps to the battery.
The battery cable and the battery sensor cable must have been connected to the same channel
number.
6.2. Steps to start a battery test
1. Select the channel to which the battery has been connected

English
9
2. Enter the battery parameters:
a. Select the battery type.
b. Enter the C5 capacity. (The C5 capacity is the specified capacity for a 5 hours
discharge.)
c. Description is optional, but useful in the list of results.
d. When a battery has not been charged properly, it can be worthwhile to recondition
the battery by increasing the discharge/charge cycles. If you do not wish to
recondition the battery you can leave the default option to 1.
The voltage 12V/24V is automatically detected. 24V batteries can only be tested if the BTS
has also a 24V charger inside (Option for 4-channel model only).
A set of two 12V batteries in series must be split and the 12V batteries must be tested
separately because their capacities may differ.
Usually only 24V Lithium ion battery packs are tested as 24V batteries.

English
10
3. Start the test by the button “Test battery channel x”
Tabla de contenidos
Manuales populares de Equipo de prueba de otras marcas

SMART
SMART KANAAD SBT XTREME 3G Series Manual de usuario

Agilent Technologies
Agilent Technologies BERT Serial Manual de usuario

Agilent Technologies
Agilent Technologies N3280A Manual de usuario

Vernier
Vernier Go Direct Voltage Manual de usuario

Lifeloc
Lifeloc R.A.D.A.R. Manual de usuario

Fluke
Fluke T5-600 Instrucciones de funcionamiento e instalación