Models Applicable to This Manual
FFC2-1
FFC4-2
FFC3-1
FFC6-2
Important Note to the Installer:
Please ensure that this document is passed to the user
cleaning and general maintenance and should be kept for
reference.
Electrical Safety
Foster Refrigerator recommends that the equipment is electrically connected via a Residual Current Device; such as a
Should it be necessary to replace the fuse. The replacement fuse must be of the value stated on the serial label for the
cabinet.
Disposal Requirements
If not disposed of properly all refrigerators have components that can be harmful to the ennviroment. All old
General Safety
Do not use electrical appliances inside the storage compartment.
stored or ‘locked in’ the applicance.
persons in order to avoid hazards.
Climate Class
English
1

Start-Up and Test Sequence
before
hands.
.
Acvate the controller
Per drawer display:
Note: If pressed and held for 5
seconds then released a ‘Test
3 Seconds
Cancel Test Sequence
Per drawer display:
English
2

User Adjustments
Check Storage Temperature Set Point
Per drawer display:
1/2 Second
Temperature Sengs
2 Seconds
Fridge
Freezer
Indicator light goes out
When changing drawer temperatures please ensure that all product has been unloaded and that the counter is
le for a minimum period of 1 hour to acclimase to the new temperature.
For freezer temperatures only place already frozen product inside. This unit is not designed to freeze down
product.
Standby
applied to it. This mode may be used
for interval cleaning regimes and short
supply should be isolated.
3 Seconds
Defrost
Automac -When set to freezer
that ensures the evaporator coil is
clear from ice.
Manual Defrost - If required
on either fridge or freezer
temperatures a manual defrost
display. 2 Seconds
English
3

Alarms and Warnings
Counter High Temperature Alarm Air Temperature Probe T1 Failure
Drawers
Loading
Evaporator Fan Protecon
Do NOT block the fan airow
Locking
Overshelf and Can Opener (Oponal)
Both the overshelf & can opener opons are only supplied ed to models from factory.
The overshelf should hold no more than 80kg evenly distributed.
English
4

Keypad Security Sengs
’ then use either ‘ ‘ or ‘ ‘ to select ‘ ’. While holding ‘ ’ use either ‘
‘ or ‘ ‘to change from a ‘ ’ to ‘ ’ to resume.
Cleaning and Maintenance
Important: Before cleaning, the unit should be put into standby and then the power supply should be turned o at
the mains. Please do not plug or unplug the unit with wet hands. Only when cleaning has been completed and the
unit is dry should the counter be turned back on at the mains.
Suitable P.P.E (Personnel Protecve Equipment) should be worn at all mes.
>
chlorines as these may cause damage.
> Bin Removal
> Condenser Cleaning:
only by your supplier (this is
cause premature failure of the motor/compressor.
>
.
>
>
>
English
5

Before calling your supplier please make sure that:
a.
displays illuminated?
b. The unit is not in standby
c.
d.
e. The condenser is not blocked or dirty
f. The products are placed in the unit correctly
g. Defrost is not in progress or required
h. The temperature is set to the desired set point for either fridge or freezer temperatures.
English
6

Remarque importante à desnaon de l’installateur.
Sécurité électrique
Classe climaque
Consignes générales de sécurité
vivant dans l'appareil.
Modèles concernés par ce manuel
FFC2-1
FFC4-2
FFC3-1
FFC6-2
Exigences relaves à l’éliminaon en n de vie
Français
7

Démarrage et séquence de test
ensuite ‘ ‘
Mise en marche du régulateur
Au moyen de l’écran d’achage de chaque roir:
Remarque : Une pression
3 Secondes
Annuler la séquence de test
Au moyen de l’écran d’achage de chaque roir:
Appuyer et relâcher
‘
Français
8

Mode de réglage ulisateur
Vérier le point de consigne de température de stockage
1/2 Second
Consignes de température
2 Secondes
Froid n
Lors d’un changement de température de roir, veiller à bien sorr tous les produits de l’appareil et à le laisser
s’acclimater à la nouvelle température pendant au moins une heure.
Pour des températures négaves ne placer dans l’appareil que des produits déjà congelés. Cet appareil n’est pas
prévu pour congeler des produits.
3 Secondes
Dégivrage
Automaque
Dégivrage manuel
2 Secondes
Veille
Au moyen de l’écran d’achage de chaque roir:
Français
9
Este manual sirve para los siguientes modelos
3
Tabla de contenidos
Idiomas:
Otros manuales de Refrigerador de ITW