Isel iOP-19-TFT Manual de usuario

isel Germany AG
isel Germany AGisel Germany AG
isel Germany AG, D-
36124 Eichenzell, Buergermeister
CNC control panel iOP
Operating
36124 Eichenzell, Buergermeister
-Ebert-Str. 40 +49 (0 6659 981-0
CNC control panel iOP
-19-
TFT
Operating
instructions
+49 (0 6659 981-776
TFT

Abbreviations used in these
operating instructions
MRL Machinery Directive 2006/42/EC
RL EMC Directive 2004/108/EC
NRL Low Voltage Directive 2006/95/EC
Symbols used
The operating instructions contain important information / issue and danger symbols, which
must be noted and complied with:
Warning!
This symbol warns of potential danger to health, life and limb.
Warning! Potentially lethal voltage
This sign warns of danger to life and limb due to the presence of high-voltage
electrical circuits. Failure to observe the danger can result in severe injury or
death.
Attention!
This symbol means important instructions are being given. Failure to observe the
instructions may result in e uipment malfunction or damage to machinery.
Information:
This symbol means important information or advice is being given.
Complying with safety information
Prior to using the iOP-19-TFT CNC control panel or making any alterations to
the electrical installations in or on your machinery, please ensure that you have
carefully read through the safety information in these operating instructions

The information, technical specifications and dimensions contained in this booklet represent the
latest available data at the time of going to print. The occurrence of misprints and other errors
cannot, however, be completely ruled out. We thank you in advance for bringing such errors to
our notice and we welcome any improvement suggestions you may have.
We are obliged to draw your attention to the fact that the software and hardware brand names
and trade marks appearing in this booklet are protected under patent.
All rights reserved. No part of this booklet may be reproduced, electronically processed,
duplicated or distributed in any form whatsoever (printed out, photocopied, etc.) without the
written permission of isel Germany AG.
isel Germany AG
isel Germany AG isel Germany AG
isel Germany AG
machines and controllers are CE compliant and labelled
accordingly. This e uipment must not be operated until the CE safety guidelines
applying to all associated machinery parts and components have been
fully complied with.
isel Germany AG
isel Germany AG isel Germany AG
isel Germany AG accepts no liability for damage to e uipment or malfunction
where modification has been made to the controller.
The EMC test is only valid for CNC control panels with original ex-works
configurations.
Manufacturer: isel Germany AG
Buergermeister-Ebert-Straße 40
D-36124 Eichenzell
Tel.: +49 (0) 6659 981-0
Fax: +49 (0) 6659 981-776
http://www.isel.com
Article No. : 371100 1000 (original operating instructions)
Date of issue: 06/2014_RL
Technical specifications may change without prior notification.
Current operating instructions and e uipment manuals can be downloaded at:
www.isel-data.de/manuals

Table of contents
1
General Information ........................................................................................................... 5
1.1
Safety information .............................................................................. …………………5
2
Product description ............................................................................................................. 6
2.1
Versions .......................................................................................................................... 6
2.1.1 CNC control panel iOP-19-TFT with 19“ touch screen ....................................................... 6
2.2
Description of control elements ..................................................................................... 7
3
Connections of the control elements ................................................................................ 10
3.1
Connection of the controls for the control PC .............................................................. 10
3.2
Power supply for the CNC control panel ..................................................................... 11
3.3
Connection of machine controls ................................................................................... 12
4
Faults .................................................................................................................................. 13
5
Service and maintenance .................................................................................................. 13
6
Technical Data ................................................................................................................... 14
6.1
Technical Data iOP-19-TFT ......................................................................................... 14
7
C Declaration of Conformity ......................................................................................... 15

CNC control panel iOP-19-TFT
Page - 5
1 General
Please read these operating instructions through to the end and carefully follow the
instructions given. Failure to comply with these operating instructions can result in damage
to property, personal injury or death.
1.1 Safety note
The iOP-19-TFT CNC control panel is designed in
accordance with state of the art technology and in full
compliance with recognised safety standards.
This e uipment must only be operated in a fault-free
condition. Any observed defect must be removed before
the e uipment is used. This e uipment must only be
operated by trained personnel. Children should not be
allowed in the vicinity of the e uipment.
This e uipment must only be used in accordance with its
intended purpose, i.e. for the monitoring and control of
CNC machinery linked to a separate iSR/iPC series
control computer.
E uipment operations must only be carried out by
authorised, ualified personnel and in full compliance
with electrical industry regulations and safety standards.
Ensure the e uipment is fully disconnected from the mains
supply before opening the cover and carrying out any
electrical installation work.
Ensure there is sufficient ventilation in the immediate
vicinity of the monitor. Ensure the e uipment is mounted
in a safe and stable position and that the ventilation ports
in the monitor housing are left open and unobstructed.
E uipment assembly and operation must be undertaken in
compliance with all relevant conformity declaration
standards. The guidelines and threshold values issued by
the manufacturer do not provide protection in the event of
improper use of the e uipment.
The e uipment must not be exposed to excessive levels of
humidity or vibration.
Ensure that all operators are familiar with the content of
these operating instructions and that such content is
strictly adhered to at all times!

CNC control panel iOP-19-TFT
Page - 6
2 Product description
2.1 Versions
Type Description Article No.
iO -19-TFT without keyboard, RAL
3011 371100 1000
with German keyboard,
(optional)
with silicon keyboard,
RAL 3011 371200 0001
with English keyboard,
(optional)
Silicon keyboard, RAL
3011 371200 0002
2 1 1 CNC control panel iOP-19-TFT with 19“ touch screen
standard
optional
robust aluminium housing
Aluminium "stainless steel-look" front
panel
Simple assembly using VESA 100/100
mounting
Integrated machinery control elements
19“ TFT with touch screen
Max. resolution: 1280 x 1024 pixels
3 USB connections
pull-out connecting cable, compatible
with isel control computer
Stand
Swivel arm for connection to PS
profile
Simple keyboard / mouse storage
compartment
Superior uality, built-in 105-key
silicon German / English keyboard
with touch pad
Two-handed operation
Override potentiometer
Available in 3 colours, RAL 3011,
RAL

CNC control panel iOP-19-TFT
Page - 7
2.2 Description of control elements
In the standard version, the most important control elements (buttons, switches) are mounted
on the CNC control panel.
Machinery control elements

CNC control panel iOP-19-TFT
Page - 8
No. lement Description
1 Power ON button Switches the power amplifiers on.
2 Fault indicator The fault indicator signals the presence of a fault in the safety
circuit.
3 STOP button
Interrupts the NC program currently being executed. Pressing
the STOP button a second time terminates the NC program
currently being executed (does not apply to all control
configurations, only to the ProNC setting).
4 START button
Pressing the START button initiates execution of the current
NC program or, where the program has been interrupted,
allows the current program execution to be continued.
5 ACK (acknowledge)
button
The ACK button is used in Set Up mode and must be pressed
to allow the shafts to be driven when the cover is open.
6 COVER button
The COVER button is pressed to allow the cover to be opened
(where a cover has been provided). The cover can only be
opened when the conditions listed under "Operating Mode
Selector Switch" have been fulfilled. Once the white signal
lamp on the COVER button is illuminated, the cover can be
opened.
7 Operating Mode
Selector Switch
This key switch allows the unit to be switched between the
Automatic Operation and Set Up modes. In Automatic
Operation, the cover (or door) of the machine can only be
opened when the shafts are not in motion and the cutting
spindle has been switched off. In the Set Up mode, the cover
(or door) of the machine can only be opened when the working
spindle has been switched off. In the Set Up mode, the shafts
can be activated with the cover open by pressing the ACK
acknowledgement button.
8 EMERGENCY
STOP button
Pressing this button immediately disconnects the power supply
to the motor, converter and working spindle.
Switching into the AUTO ->TEST operating mode whilst the workpiece is
being machined brings the working spindle to a halt Switching back to the
AUTO mode restarts the working spindle Before switching back to the
AUTO operating mode, ensure that all moving parts are in the stop
position Failure to do this can result in damage to the working spindle or
workpiece
No. lement Description
9 PC START button Switches the computer "on" and "off".
10 Two-handed
operation Control buttons for two-handed operation (optional)

CNC control panel iOP-19-TFT
Page - 9
Control computer control elements
No. lement Description
11 USB connections
The iOP-19-TFT is fitted with an integrated USB hub. This
provides integrated touch screen connection. The three USB
ports allow e uipment such as USB sticks, a USB keypad, a
WIBU dongle or an external CD ROM drive to be connected.
The USB hub is provided with its own +24V power
supply (active USB hub) Power is fed to the hub via
the machinery control element connecting cable
(see Chapter 3)
If the CNC control panel has been connected to an isel
computer not fitted with a +24V supply (e g iPC15), the
touch screen and USB ports will remain inoperative

CNC control panel iOP-19-TFT
Page - 10
Screen control elements
The screen control elements are located in the service hatch
3 Control element connection
All CNC control panel connecting cables are optimised for use with isel
iSR/iPC series control computers These connecting cables should not be
extended Doing so may impair the performance of the CNC control panel
nsure the protective earth conductor is adequate with a diameter of at
least 2.5mm
2
(screened cable) or 4mm
2
(un-screened cable) and
connected between the iOP-19 terminal and the safety bus bar of
your machine!
3.1 Connecting t e control PC control elements
DVI connecting cable
This cable is fitted with a DVI plug for connection to the graphic card of
your computer.
No. lement Description
1 Menu (top) Use the menu to navigate to the top
2 Menu (bottom) Use the menu to navigate to the bottom
3 ON / OFF Switches the monitor "on" and "off"
4 Menu (enter) Opens the menu / confirms settings
5 Menu (back) Steps the menu back one level
6 LED Indicates operating condition: redoff, greenon
1
2
3
4
5
6
12
Tabla de contenidos