IRIDEON AR500 Manual de usuario

02-9642-0002A
IRIDEON
AR500Exterior Wash Luminaire
Standard Version Installation Manual


ii I
RIDEONAR500EXTERIOR WASH LUMINAIRE INSTALLATION MANUAL
02-9642-0002A
28-Jul-00
AR500Exterior Wash Luminaire
Standard Version Installation Manual
Reporting Errors and Recommending Improvements
You can improve this manual. If you find any mistakes, or if you know of a way
to improve procedures, please let us know. Send your letter to:
IRIDEON, Inc.
201 Regal Row
Dallas, TX. 75247 USA.
attn: Service Manager
Our FAX number in Dallas is (214) 630-5867.
Patent and Trademark Notice
IRIDEON, Composer, AR5, AR6, AR50and AR500are
trademarks owned by IRIDEON, Inc., 201 Regal Row Dallas, TX 75247.
IRIDEON products and services are protected by one or more of the following
patents, and other pending patent applications worldwide: U.S. Patents No.
5,186,536; 5,073,847; 4,602,321;4,392,187; Australia Patents No. 576,400;
546,433; 649,264 Canada Patents No. 1,259,058; 1,181,795; 2,070,670,
2,050,375 Europe Patents No. 0 192 882; 0 140 994; Japan Patent No.
1,533,011; Singapore Patent No. 663/90; Spain Patent No. 548.328, Mexico
Patent No. 180,148.
© 1994-1996 IRIDEON, Inc. All Rights Reserved.
Revision History
Basic 20 October 1994
Rev. A 14 June 1996

STANDARD VERSION INSTALLATION 3
02-9642-0002A
28-Jul-00
AR500Exterior Wash Luminaire
Standard Version Installation
Each AR500™ fixture is shipped in two cartons, with the stanchion in one
carton and the head assembly in another carton. Be sure that you have one
stanchion and one head assembly for each fixture to be installed.
Included in each shipment is an installation tool kit. Check to be sure the tool kit
contains the following items:
1-15/16" open-ended wrench
3/16" T-handle Allen wrench
100Ωtermination resistor
Some additional tools will also be necessary in order to complete the installation.
You will need to obtain the following item:
#2 Phillips screwdriver
#2 Straight slot screwdriver
3/4″(or 19mm) socket
9/16″(or 15mm) Socket
The installation site must provide an adequate mounting platform, sufficient
clearance for focus adjustment of the head assembly and stanchion, sufficient
access for relamping and other servicing, and provisions for power and data
cabling.
AR5ISO
AR500 Exterior Wash Luminaire, Standard Version

4IRIDEON -AR500EXTERIOR WASH LUMINAIRE INSTALLATION MANUAL
02-9642-0002A
28-Jul-00
1 Site Preparations
Note: The installation contractor is responsible for compliance with local
electrical codes.
The luminaire stanchion is provided with 10 feet (3 m) data cable and 10 feet
(3 m) power cable for external termination. To ensure proper operation, the
installation site should be equipped with waterproof junction boxes for data and
power cable termination. Data and AC power for each luminaire should be
terminated in separate junction boxes, unless a single barriered junction box is
installed. Terminal strips, not wire nuts, must be used to terminate wiring.
1.1 Mounting Platform for Stanchion Assembly
The stanchion mounting platform must have a diameter (or distance across flat
sides) of at least 18 inches (45.00cm). The luminaire's mounting plate includes
mounting holes sized to provide clearance for four sets of 3/8-18 (M10)
(preferably stainless steel). The hole pattern for the mounting plate is a square
that is 10.10 inch (25.65cm) on a side [or 10-7/64 inches (5.65cm)square].
Note: Be sure to use four sets of 3/8 inch (M10) hardware when installing unit.
FTPRNT2
18.00"
(45.72cm)
TYP.
18.00" DIA
(45.72cm DIA)
10.10"
(25.65cm)
TYP.
10.10"
(25.65cm)
TYP.
7.13"
(18.1cm)
TYP.
45o
TYP.
CIRCULAR
OCTANGULAR
18.00" SQR.
(45.72cm SQR.)
SQUARE

S
TANDARD VERSION INSTALLATION 5
02-9642-0002A
28-Jul-00
1.2 Clearance and Access
As shown, the head assembly can be rotated to any orientation thru 348°and
requires 13 inch (33 cm) radius clearance around the vertical tilt axis. The
stanchion assembly can be rotated 14°and requires 33-9/16 inches (85.3 cm)
radius clearance around the horizontal pan axis.
WARNING: This appliance must be earthed. Flammable objects must be
kept a minimum of 13′-2″(4.0 m) from lens.
10-1/8"
10-1/8"
R33-9/16"
R8"
STDTOPVW
BDC
TILT
STOP
6
6
TILT
STOP
AR5SIDE
R13"
(R33cm)
13-1/8"
(33.4cm)
8"
(20.3"cm) 27.5"
(69.9cm)
19.5"
(49.5"cm)
8"
(20.3cm)
(20.3cm)
(85.3cm)
(25.7cm)
(25.7cm)
45

6IRIDEON -AR500EXTERIOR WASH LUMINAIRE INSTALLATION MANUAL
02-9642-0002A
28-Jul-00
1.3 Input Power and Control Cabling
Each AR500 luminaire requires 1000 watts of power at the specified voltage and
frequency. The luminaire is provided with 10 feet (3 m) of unterminated power
cable type SJOW-A 16-3 (1.5mm2). Power wiring is to be connected as follows:
Wire Connection
Black
*(Brown) AC Line
White
*(Blue) AC Neutral
Green
*(Green/Yellow) Ground
* - European Model
GRN
WHT
BLK <LINE
<NEUT
<GND
GRN
WHT
BLK
WIRING1
The AR500 luminaire is controlled by DMX-512 data connected to the two
shielded twisted-pairs provided in the data cable. For DMX In and Thru
configuration, connect data wiring as follows:
Wire Connection
White/Red Positive Data
Black/Green Negative Data
Drain Ground
FROM PRIOR
J-BOX +DATA
-DATA
DRAIN
+DATA
-DATA
DRAIN
T
O
S
TAN
C
HI
O
N
J-BOX TO NEXT
J-BOX
WRGDIAG3
IRIDEON, Inc recommends Belden 9729 cable for control signal distribution to
the luminaire.

S
TANDARD VERSION INSTALLATION 7
02-9642-0002A
28-Jul-00
1.4 Data Wire Termination
If data cable is installed in a daisy-chain (feed-thru) configuration, install 100Ω
termination resistor (provided) at end-of-line between positive(white or red) data
line and negative(black or green) data line. If data splitter is installed, the last
luminaire on each data run, as well as the transmitter to splitter data run, must be
terminated. (See diagram in 1.7 Multiple Data Run.)
WHITE
+
-
BLACK
GREEN
RED+
-
CHAIN1
-OR-
1.5 Cable Specifications
AC POWER INPUT (to stanchion)
Wire Gauge: 16 AWG 3-conductor *(1.5mm2×3-conductor)
Rating: 300V / 13 Amps
O.D.: 0.345 inches(8.77cm) *[0.433inches(11mm)]
DATA INPUT (to stanchion)
Wire Gauge: 22 AWG 2-shielded-pair w/ drain wire
Shield (inner): Aluminum/mylar
Shield (outer): Tinned copper braid
Rating: 300V
O.D.: 0.280 inches(7.11cm)
* European model.

8IRIDEON -AR500EXTERIOR WASH LUMINAIRE INSTALLATION MANUAL
02-9642-0002A
28-Jul-00
1.6 Single Data Run
The following illustration displays a five units layout with a single data run.
Notice the 100Ωresistor at the end of the data line.
AC
DMX
TRANSMITTER
BELDEN 9729
(NOT SUPPLIED)
TERMINATING
RESISTOR
100
UNIT
NO. 5
UNIT
NO. 3
UNIT
NO. 2
UNIT
NO. 4
UNIT
NO. 1 DMX
ADDR:
17
DMX
ADDR:
13
DMX
ADDR:
9
DMX
ADDR:
5
DMX
ADDR:
1
AC AC AC AC
Ω
ΩΩ
Ω
AR5CTNL1
*JUNCTION BOX
(TYPICAL)
1.7 Multiple Data Run
The following illustration displays a six unit layout with a buffered DMX
splitter. Notice the three 100Ωtermination resistors.
DMX
ADDR:
1
DMX
ADDR:
5
DMX
ADDR:
9
DMX
ADDR:
13
DMX
ADDR:
17
DMX
ADDR:
21
UNIT
NO. 2 UNIT
NO. 3
UNIT
NO. 4 UNIT
NO. 5
UNIT
NO. 6
UNIT
NO. 1
DMX
TRANSMITTER
TERMINATING
RESISTOR
100Ω
ΩΩ
ΩBUFFERED
DMX
SPLITTER
AC AC
AC AC
AC
AC TERMINATING
RESISTOR
TERMINATING
RESISTOR
100Ω
ΩΩ
Ω
100Ω
ΩΩ
Ω
AR5CTNL2
*JUNCTION BOX
(TYPICAL)

S
TANDARD VERSION INSTALLATION 9
02-9642-0002A
28-Jul-00
2 Luminaire Installation Procedure
The following chapter describes unpacking shipping cartons, installing,
preparing, and wiring the stanchion and head unit for the AR500 luminaire. This
section also covers lamp installation and focus procedures.
2.1 Unpack Shipping Cartons
Note: Stanchion weighs 82 pounds (37.19Kg) or less, depending on voltage
configuration; head enclosure weighs 62 pounds (28.12Kg) for a total weight of
144 pounds (65.31Kg). The luminaire requires two people for installation.
1. Remove stanchion and head assembly from cartons.
2. Locate tool kit (provided).
2.2 Install Stanchion
3. Set stanchion on mounting pad in required orientation. Loosely secure
stanchion to pad using 3/8 inch (M10) hardware (not provided). Typically,
this requires four flat washers, four lock washers, and four hex nuts.
2.3 Prepare Stanchion
4. Remove stanchion cap.
5. Set thumbwheel to address desired on switch board located at top of
electronics plate (detailed in 3 Fixture Address).
MOTOR OUTPUT
16 PIN CPC
CONNECTOR
THUMBWHEEL
ADDRESS
SWITCH
DATA INPUT
9 PIN CPC
CONNECTOR
STNCHPRP
MOUNTING
HARDWARE
(4 PLACES)
Otros manuales para AR500
1
Tabla de contenidos
Otros manuales de Equipo de iluminación de IRIDEON
Manuales populares de Equipo de iluminación de otras marcas

Qazqa
Qazqa Suplux SL 3 Black 103062 Manual de usuario

Commercial Electric
Commercial Electric 54568141 Manual de usuario

CREE LIGHTING
CREE LIGHTING 304 Series Manual de usuario

Goobay
Goobay 49867 Manual de usuario

ECOMAN ITALIA
ECOMAN ITALIA LED T8 Manual de usuario

Alkalite
Alkalite Krypton KT-81 Manual de usuario












