PDU SW-1081
PDU SM-1681
PDU

User Manual PDU SW-1081/ SM-1688
1
Table of Contents
1. Introduction .............................................................................................................. 2
2. PDU Package ............................................................................................................. 3
3. Function ................................................................................................................... 4
4. Installation ............................................................................................................... 6
5. Web Interface ............................................................................................................ 8

User Manual PDU SW-1081/ SM-1688
2
1. Introduction
The PDU is an Internet ready device designed and is equipped with an intelligent current-
meter (True RMS) that will indicate the total power consumption of a power strip.
The PDU offers an easy set up and user-friendly communication software. This software
provides the function that assistant manager to remotely monitor the multiple PDU power
consumption to realize the total current power consumption and utilization for the
enterprises.
Features:
Built-in web server, manager can real time to monitoring the current consumption of
the power strip.
Build-in true RMS current meter.
Setup easily, meter can read the IP address directly.
Homepage support SS .
Provide audible alarm when the power consumption over the threshold of warning and
overload.
Send the email and traps when the power consumption exceed the trigger value of
warning or overload to the PDU.
Provide utility, it can monitor a large mount of PDU at the same time.
Support the SNMP and provide MIB for the PDU to be monitored by NMS.
Provide per outlet power protection by the circuit breaker.
Real time to control outlets of PDU.
Indicate outlets status with ED.
Support power on sequence.
Option accessory can support temperature and humidity detection.

User Manual PDU SW-1081/ SM-1688
3
2. PDU Package
The standard PDU package contains a Power Distribution Unit with supporting hardware
and software. The components of the package are:
Power Distribution Unit.
Rack mount Brackets.
CD-ROM, it contains:
User Manual.
PDU Software.
MIB: Management Information Base for Network. (PDUMIB.mib)
Adobe Acrobat Reader.

User Manual PDU SW-1081/ SM-1688
4
3. Function
Interface
Single current
bank
Functions Description
Ethernet RJ45 port for network communication port.
Audible Alarm Warning- 1 beep in 1 second.
Overload- 3 beeps in 1 second.
Note: The audible alarm will keep beeping until the current
gets back to normal and the current is lower than the threshold
to 0.5 amps.
Function Button Press and release to turn off the warning beeping. The
overload beeping can not be cancelled.
Press and hold the key after 2 beeping; it can let the meter
to show up the IP address
Press and hold the key after 4 beeping; it can change the
way to get IP by DHCP or fixed IP.
Press and hold the key after 6 beeping; it can reset PDU
back to default setting.
Meter 3 digits to display current and IP Address.
ID The identification of power bank or PDU.
ED Indicator SS (yellow): ight on means web access is protected by SS .
DHCP (Green): ight on means PDU gets IP address by DHCP.
PDU (Green): Indicate each output power status.
Status (Red): Indicate each circuit status. (by model)

User Manual PDU SW-1081/ SM-1688
5
ENV RJ11 for ENV probe attached.
Circuit Breaker Overload power protection.

User Manual PDU SW-1081/ SM-1688
6
4. Installation
This section will provide a quick instruction to install the PDU.
Rack Mount Instructions
A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the
operating ambient temperature of the rack environment may be greater than room
ambient. Therefore, consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature specified by the
manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such that the
amount of air flow required for safe operation of the equipment is not compromised.
C) Mechanical oading - Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.
D) Circuit Overloading - Consideration should be given to the connection of the equipment
to the supply circuit and the effect that overloading of the circuits might have on over
current protection and supply wiring. Appropriate consideration of equipment nameplate
ratings should be used when addressing this concern.
E) Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections other than direct connections to
the branch circuit (e.g. use of power strips)."
Diagra

User Manual PDU SW-1081/ SM-1688
7
Hardware
1. Install mounting brackets.
2. The PDU comes with brackets for mounting in a rack. To mount the PDU into a rack
performs the following procedure:
3. Attach the mounting brackets to the unit, using the four retaining screws provided for
each of the brackets.
4. Choose a location for the brackets.
5. Align the mounting holes of brackets with the notched hole on the vertical rail and
attach with the retaining screws.
6. Connect input and output power.
7. Connect Ethernet cable to the PDU.
8. Switch on the PDU.
Note 1:
The default setting for the way to get IP address is DHCP. If PDU can not get the IP from
DHCP server, the IP address will stay at 192.168.0.216
Note 2:
TO SETUP THE NETWORK SYSTEM FOR PDU, STRONG Y RECOMMAND TO BUI D UP THE
POWER MONITORING NETWORK SYSTEM ISO ATED WITH THE OTHERS, IN ORDER TO
KEEP THE STABI ITY OF GETTING POWER INFORMATION AND SYSTEM OPERATION.

User Manual PDU SW-1081/ SM-1688
8
5. Web Interface
Login:
Input the PDU IP address in web browser.
Default ID is snmp.
Password is 1234.

User Manual PDU SW-1081/ SM-1688
9
Infor ation: PDU
Display total PDU and each outlet power consumption.
When plug the option device - ENV probe, it will display temperature and humidity
information.