Passive infrared motion sensor with triple technology
Congratulations, you have just purchased a product with Intelbras quality and safety.
The IVP 9000 MW motion sensor combines microwave detection with passive infrared detection, adopting
advanced signal analysis technology to prevent accidental tripping in high-risk intrusion environments.
Developed with 2 Quad PIR sensors and the combination of at and hemispherical Fresnel lenses, it increases
the efciency of motion detection and reduces undetected areas below the sensor.
To facilitate the installation of the sensor and optimize the installation time, the cabinet contains a snap-in
system using front and rear cover connectors.

Care and safety
» Follow all instructions in the manual for assembling and installing the product.
» LGPD – Data processing by Intelbras: Intelbras does not access, transfer, capture or perform any type of processing of
personal data from this product.
» This product is intended for INDOOR and SEMI-OPEN environments.
Fechado Externo
Semi-open Closed Outside
» Do not touch the surface of the infrared (PIR) sensor. If necessary, use a soft, dry cloth for cleaning.
» Do not use the sensor in areas with sudden temperature changes such as air conditioners and heaters, fans, refrigerators
and ovens. Do not expose the sensor directly or to reections from sunlight.
» The
PET
function is intended for lowland animals weighing up to 10 kg. If the animal is on top of a bench, for example,
the
PET
function can be overridden.
» When installing the sensor in environments with the presence of animals, it is recommended to congure the sensor for a
semi-open environment, switch S1 position 3 activated.This way the sensor makes the appropriate sensitivity adjustment
and disables the Anti-Camouage function, if it is enabled.
» Do not place objects in front of the sensor. To secure the detection area, avoid curtains, screens, screens, or any object
that blocks the scan.
» The sensor must be installed where an intruder can be easily detected, that is, where it moves transversely to the de-
tection beams.
» The sensor must be installed on a at, xed, icker-free surface, with a height between 2.0 and 2.4 meters. It is recom-
mended to install the sensor parallel to the wall for the greatest detection range.

Detection area (Top view)
Detection angle (Side view)
2,1 m
0,1 3 6 9 12 15 18 (m)
Side view
0,1 3 6 9 12 15 18 (m)
2,1 m

Summary
1. Technical specications 6
2. Características 6
3. Product 7
4. Installation 8
4.1. Microwave sensitivity adjustment ...............................................................9
4.2. Operating mode settings ....................................................................10
4.3. Process completion ........................................................................12
5. Operation 13
6. Test 13
7. Homologation 13
Warranty term 14

6
1. Technical specications
Operating voltage 9 ~16 Vdc
Operating current 50 mA
Detection angle 110°
Detection range (PIR and MW) 18 meters
Detection method Microwaves and PIR (AND)
Number of pyroelectric sensors 2
Pyroelectric sensor type Quad
Microwave frequency 10,525 GHz
Animal immunity up to 10 kg
Sensitivity Automatic (factory default)
Minimum
ALARM output NC, 28 Vdc and 100 mA max.
Anti-violation Rear tamper
LED indicators
LED: Yellow (PIR)
Red (MW)
Blue (Alarm)
Startup time 60 seconds
Relay opening time 3 seconds
Operating Temperature -10 °C to 50 °C
Recommended installation height 2.1 meters
Dimensions (W × H × D) 67 × 134 × 54 mm
Weight 134 g
2. Características
» Anti-camouage;
» Anti-tamper (tamper key);
» Look down (creeping zone);
» Automatic temperature compensation;
» RFI/EMI immunity;
» Automatic adjustment of infrared sensitivity (PIR);
» Microwave sensitivity adjustment (MW);
» Immunity to creeping animals weighing less than 10 kg;
» Ease of installation;
» Mechanical protection of the electronic circuit.

7
3. Product
1. Front cover
2. Flat lens
3. Hemispherical lens
4. LEDs
5. Closing screw
6. Wire passage seals
7. Seals for wall installation
8. Seals for corner installation
9. Connector
10. External base
11. Internal base
Board
12. Pyro sensor
13. Microwave module
14. LEDs
15. Connector
16. Tamper key
17. 4 position key
18. Trimpot microwave adjustment

8
4. Installation
» Before starting the installation, it is necessary to dene the height at which the sensor will be positioned, which can
vary from 2 to 2.4 m;
» Do not install sensors that have microwave technology close to each other, as there may be interference between them;
» The microwave sensitivity adjustment must be done according to each environment;
» For installation using the articulator, make sure that both the sensor and the bracket are securely xed in the installation
location to avoid changes in the product’s detection angle. Incorrect use of the articulator can change the sensor’s de-
tection area, creating blind spots and impairing operating efciency;
» If the sensor is installed at an angle, its detection range and PET function may be impaired in such a way as to nullify
the function.
To install the sensor, follow the procedure below:
1. Unlock the back cover by partially loosening the screw and remove it by sliding the front cover down, as shown in the
picture.
2. Route the wiring through the cable passages located on the sensor back cover.
Note:
use a tool to drill the hole in the indicated location.
Cable passage

9
3. Connect the connecting cables to the sensor terminals and install in the place to be protected. For installation directly on
the wall, 4×2 box or in a corner of the wall, break the seals indicated for the holes in the rear xing cover.
Wall mounted Mounted in the corner of the wall 4x2 box installation
Lacre Lacre
4. Installation using the articulator.
Note: the articulator does not come with the product.
Attention: if the xing bracket is inclined to the ground, the characteristics of the
PET
function will change.
Use the xing holes located on the base to x the XSA 1000 articulator, for more information about the XSA 1000 articula-
tor, consult the user manual on the website: www.intelbras.com.br
The recommended screw for attaching articulators to the product is 3.5 × 9.5 mm.
XSA 1000 Position 1
Position 2
Mounted support
5. Perform the conguration on the sensor following the guidelines.
4.1. Microwave sensitivity adjustment
Microwave
The trimpot allows you to adjust the microwave’s sensitivity.Turning the trimpot clockwise increases the sensitivity
and consequently the distance at which the microwave is able to detect movement. Turning it counterclockwise
makes the microwave less sensitive.
Note: it is highly recommended to adjust the microwave sensitivity so that detection takes place only in the
environment where the sensor is installed. This technology is capable of detecting movement through a wall, for
example.

10
In gure 1 of the example above we have the area we want to protect. Figures 5 and 6 indicate that the trimpot
adjustment exceeded the limits of the environment to be protected. In this way the microwave will detect move-
ments outside the desired area.
To make it easier to adjust the microwave cover, adjust the trimpot counterclockwise (less sensitive) and walk in
the room you want to protect. Observe the sensor motion detection. If necessary, increase the sensitivity (clockwi-
se). Repeat this process until the sensor only protects the environment where it is installed.
The gure below shows a microwave channel detection range reference.
Factory default: 50%
Microwave range
Trimpot position Maximum distance
0% up to 1 meter
25% up to 5 meters
50% up to 12 meters
75% up to 15 meters
100% up to 18 meters
4.2. Operating mode settings
The key (S1) allows you to congure the sensor’s operating mode:
Key 1 – LED: works in conjunction with the LED input to control the visual indication of motion detection.
LED
Key 1 LED input LEDs
Condition Result
ON 12 Volts LEDs on
OFF 0 Volts LEDs on
ON 0 Volts LEDs off
OFF 12 Volts LEDs off