1. General Information
1.1 Items Shipped With Water Heater
The following items are shipped with the water heater; upper
mounting bracket (1), condensate drain (2), communication
cable (3), and Operation and Installation manual (4).
Note: Items 5 through 8 are spare parts shipped with the
unit. Two buss fuses, 10 Amp (5), electrode seal (6),
O-rings #015 (7), and face seals (8).
IQ-007
1
2
3
56
7
8
SPARES
4
To avoid product damage, personal injury, or
even possible death, carefully read, understand,
and follow all the instructions in the Installation
and Operation manuals before installing this
product. Improper installation, adjustment,alteration, or
maintenancecan cause injury,lossof life, and/or property
damage.Thiswater heater should be installed and serviced
ed technician. The lack of proper service can
result in a dangerous condition.
This manual contains safety information, installation
instructions, and maintenance procedures. It must be left
with the homeowner or placed near the water heater in a
noncombustible place. The homeowner should retain this
manual for future reference.
WARNING
Ifthe information in these instructions is not followed
exactly, afireor explosioncould resultcausing
propertydamage, personal injury, or death.
—
Donot store or use gasoline or other flammable
vaporsand liquids in the vicinity of this or any
otherappliance.
WHATTO DO IF YOU SMELL GAS
•
Donot try to light any appliance.
•
Do not touch any electrical switch; do not use
anyphone in your building.
•
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
•
Ifyou cannot reach your gas supplier, call the
firedepartment.
—
Installationand service must be performed by
aqualifiedinstaller, service agency, or the gas
supplier.
— Ne pas entreposer ni utiliser d’essence ou
ni d’autres vapeurs ou liquides inflammables
àproximité de cet appareil ou de tout autre
appareil.
QUEFAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ
•
Nepas tenter d’allumer d’appareil.
•
Ne touchez àaucun interrupteur; ne pas vous
servir des téléphones se trouvant dans
lebâtiment.
•
Appelezimmédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions
dufournisseur.
•
Sivous ne pouvez rejoindre le fournisseur,
appelezle service des incendies.
— L’installation et l’entretien doivent être assurés
parun installateur ou un service d’entretien
qualifiéou par le fournisseur de gaz.
AVERTISSEMENT
Assurez-vousde bien suivre les instructions données
dans cette notice pour réduire au minimum le
risqued’incendie ou d’explosion ou pour éviter tout
dommagematériel, toute blessure ou la mort.
FACTORYPRESETFORUSEWITH
NATURAL GA S
Direct-VentAutomaticInstantaneousWater Heater
(Chauffe-eauautomatiqueinstantanéàventilationdirecte)
FORINDOORINSTALLATIONONLY
(POURINSTALLATIONÀL'INTÉRIEURSEULEMENT)
120Volt,60Hz,5Amps
TypeofGas
(Typedegaz)
:
.. . . . . . . . . . . .. . .
InputRating
(EntrerleClassement)
:Btu/hrMaximum. . .
Btu/hrMinimum. . .
MaximumInletGasPressure:. . . . . . . . . . . .
MinimumInletGasPressure:. .. . . . . . . .. .
MinimumInletGasPressure(foradjustments): ..
MaximumWaterPressure: ..... . . . . . . . .
MinimumWaterPressure: ... . . . . . . . . . .
RecoveryRating: .. . . . . . . . . . . . . . .. .
.. . .. .. . ... . . .. . . .
ThermalEffi
ciency/:
EnergyFactor:
NOxEmissions:
.. . . . . . .
(PursuanttoSouthCoastAirQualityManagementDistrictRule1146.2)
(Moinsde20ppm)
(Jusqu'à98%/0.94) (Jusqu'à98%/0.94)
(Moinsde20ppm)
(Dégagementsminimums)
(Desnon-combustibles) (D'uneconstruction
combustible)
(conformémentaurèglement1146.2 du"South Coast Air Quality Management District)
Topofheater
MinimumClearances
From
Non-Combustibles
FromCombustible
Construction
(Dessusduchauffe-eau)
Backofheater
(Arrièreduchauffe-eau)
Frontofheater
(Avantduchauffe-eau)
Bottomofcabinet
(Côtécanalisation)
Side(Côté)
5/8in(15.8mm)
6in(15.2cm)
6in(15.2cm)
2in(50.8mm)
12in(30.4cm)
5/8in(15.8mm)
6in(15.2cm)
2in(50.8mm)
1/2in(12.7mm)
12in(30.4cm)
IntellihotGreenTechnologiesInc.
2900W.MainSt.
Galesburg,IL61401
Phone:(877)835-1705
Email:info@intellihot.com
Web:www.intellihot.com
FactoryPreset
NaturalGas
(Réglageenusinepourgaznaturel)
199,000
20,000
13.0W.C.(3.20kPa)
8.0W.C.(2.00kPa)
8.0W.C.(2.00kPa)
150psi(1034kPa)
15psi(103kPa)
265GPH(1003LPH)
Upto98%/0.94
Lessthan20ppm
FieldConversion*to
PropaneGas
(Conversion*surplaceaugazpropane)
199,000
20,000
10.5W.C.(2.62kPa)
3.0W.C.(0.76kPa)
11.0W.C.(2.74kPa)
150psi(1034kPa)
15psi(103kPa)
265GPH(1003LPH)
Upto98%/0.94
Lessthan20ppm
CheckBoxif
Convertedto
PropaneGas
*RefertoInstallationandOperation
manualforconversionprocedure.
(Seréféreraumanueld'installationet
defonctionnementpourlaprocédurede
conversion.)
PRÉRÉGLAGESD'USINEPOURUTILISATIONAVEC
GAZNATUREL
(Pressiondegazd'arrivéemaximum)
(Pressiond'eaumaximum)
(Pressiond'eauminimum)
(Caractéristiquederecouvrement)
(Efficacitéthermique/Facteurénergétique)
(ÉmissionsdeNOx)
(Pressiondegazd'arrivéeminimum)
(Pressiondegazd'arrivéeminimum(pourajustements))
Cocherlacasesiconvertiaugazpropane
ETLSTICKER
SerialNumber:
IGT-LBL-0005-01
(Numérodesérie)
(CollantETL)
Operation and
Installation
Manual
Model: iQ250
This product complies with ANSIZ21.10.3
(2011) /CSA 4.3 Gas Water Heater. For use as
portable water heating.
WARNING
Condensate drain line (2) is shipped from the factory with
a loop held together with plastic ties. Do not remove the
ties and/or straighten the loop. This loop forms an air
block (trap) which prevents carbon monoxide from exiting
the water heater through the drain line. Improper
installation of the drain line can result in excessive levels of
carbon monoxide, which can lead to severe personal injury
or death.
1.2 Contact Information
Call us first if you have any questions about this product. We
can help you with questions about installation or operation,
or if there are damaged or missing parts when you unpack
this unit from the shipping box.
Dealer Contact Information
Due to our policy of continuous product improvement and
technology, the design and/or technical specifications are
subject to change without notice.
Serial Number: ___________________________________
Date of Installation: ___ / ___ / ______
1.3 Serial Number Plate Locations
Each unit’s heat exchanger module has its own ASME
certification plate (1). Rating plate (2) contains serial number
for the unit. Please provide this serial number when calling
for service or warranty.
Rating and safety information inside.
(Caractéristiqueset renseignements de sécurité à l'intérieur)
FACTORY PRESET FOR USE WITH
NATURAL GAS
Direct-Vent Automatic Instantaneous Water Heater
(Chauffe-eauautomatique instantané à ventilation directe)
FOR INDOOR INSTALLATIONONLY
(POURINSTALLATION À L'INTÉRIEUR SEULEMENT)
120 Volt,60 Hz, 5 Amps
Type of Gas
(Typede gaz)
:
. . . . . . . . . . . . . . . .
Input Rating
(Entrerle Classement)
: Btu/hr Maximum . . .
Btu/hr Minimum . . .
Maximum Inlet Gas Pressure: . . . . . . . . . . . .
Minimum Inlet Gas Pressure: . . . . . . . . . . . .
Minimum Inlet Gas Pressure (for adjustments): . .
Maximum Water Pressure: . . . . . . . . . . . . .
Minimum Water Pressure: . . . . . . . . . . . . .
Recovery Rating: . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
Thermal Effi
ciency / :
Energy Factor:
NOx Emissions:
. . . . . . . .
(Pursuantto South Coast Air Quality Management District Rule 1146.2)
(Moinsde 20 ppm)
(Jusqu'à98 % / 0.94) (Jusqu'à 98 % / 0.94)
(Moinsde 20 ppm)
(Dégagementsminimums)
(Desnon-combustibles) (D'uneconstruction
combustible)
(conformément au règlement 1146.2 du "South Coast Air Quality Management District)
Topof heater
Minimum Clearances
From
Non-Combustibles
FromCombustible
Construction
(Dessusdu chauffe-eau)
Backof heater
(Arrièredu chauffe-eau)
Frontof heater
(Avantduchauffe-eau)
Bottomof cabinet
(Côtécanalisation)
Side(Côté)
5/8in (15.8 mm)
6in (15.2 cm)
6in (15.2 cm)
2in (50.8 mm)
12in (30.4 cm)
5/8in (15.8 mm)
6in (15.2 cm)
2in (50.8 mm)
1/2in (12.7 mm)
12in (30.4 cm)
Intellihot Green TechnologiesInc.
2900 W. Main St.
Galesburg, IL 61401
Phone: (877) 835- 1705
Web: www.intellihot.com
Factory Preset
Natural Gas
(Réglageen usine pour gaz naturel)
199,000
20,000
13.0 W.C. (3.20 kPa)
8.0 W.C.(2.00 kPa)
8.0 W.C.(2.00 kPa)
150 psi (1034 kPa)
15 psi (103 kPa)
265 GPH (1003 LPH)
Up to 98% / 0.94
Less than 20 ppm
Field Conversion* to
Propane Gas
(Conversion*sur place au gaz propane)
199,000
20,000
10.5 W.C. (2.62 kPa)
3.0 W.C.(0.76 kPa)
11.0 W.C. (2.74 kPa)
150 psi (1034 kPa)
15 psi (103 kPa)
265 GPH (1003 LPH)
Up to 98% / 0.94
Less than 20 ppm
Check Box if
Convertedto
PropaneGas
*Referto Installation and Operation
manualfor conversion procedure.
(Seréférer au manuel d'installation et
defonctionnement pour la procédure de
conversion.)
PRÉRÉGLAGESD'USINE POUR UTILISATION AVEC
GAZ NATUREL
(Pressionde gaz d'arrivée maximum)
(Pressiond'eau maximum)
(Pressiond'eau minimum)
(Caractéristiquede recouvrement)
(Efficacitéthermique / Facteur énergétique)
(Émissionsde NOx)
(Pressionde gaz d'arrivée minimum)
(Pressionde gaz d'arrivée minimum (pour ajustements))
Cocherla case si converti au gaz propane
ETL STICKER
Serial Number:
IGT-LBL-0005-01
(Numérode série)
(CollantETL)