7
Signal Input: Full scale analogue input for the Sample & Hold and Hold
& Track circuits. Connecting a signal to the Signal Input will break the
normal of the internal white noise generator.
Signal Output: Full scale analogue output for the Sample & Hold and
Hold & Track circuits.
Level: Analogue attenuator for the Signal Input. If the knob is fully
clockwise, the input signal will be full scale. If the knob is fully
anticlockwise, no signal will pass to the Signal Input. Because the White
Noise Output is normalled to the Signal Input, the Level knob will scale
the amount of white noise normalled to the Signal Input if no external
signal is present.
Rectifier: Toggles the full wave rectifier into the input signal path. This
will force any negative portion of the bipolar signal to be inverted
to unipolar positive. If the toggle is in the left position, the rectifier is
disabled and bipolar voltage is generated from the Signal Output. If
the toggle is in the right position, the rectifier is enabled and the signal
generated from the Signal Output will be unipolar positive only.
Slew: Analogue slew control for the output signal. If the knob is fully
anticlockwise, no slew is applied to the output signal. Turning the knob
clockwise will increase the amount of slew applied to the output signal.
This can also be used as an inverse low pass filter cut off frequency
control if audio is present at the Signal Input and the module is clocked
at audio rate.