InnoSenT iSYS-4001 Manual de usuario

iSYS-4001
quick-start guide V1.1
www.InnoSenT.de
30°
45°
60°
2.2m

iSYS-4001 | quick start guide
www.InnoSenT.de
2www.InnoSenT.de - Experience and Reliability in Radar-Technology
content
• quick start
• configuration settings
• short-range configuration
• detection fields
• long-range configuration
• typicall detection patter for cars
• individual configuration
• iSYS-4001 - detection fields
• depending on mounting height
• depending on mounting angle
• detection distance (RCS)
• ambiguity range
• FSK modulation
• FMCW option
• contact
4
5
6
7
8
9
10
12
13
14
16
18
20
22
25

iSYS-4001 | quick-start guide www.InnoSenT.de
3
Experience and Reliability in Radar-Technology - www.InnoSenT.de
iSYS-4001
quick-start guide
The quick-start guide gives you a guidence to set-up the iSYS-4001 quickly in your application.
A more detailed instruction is given in the GUI - description that is available @ www.innosent.de.

iSYS-4001 | quick start guide
www.InnoSenT.de
4www.InnoSenT.de - Experience and Reliability in Radar-Technology
quick start
Install the iSYS-4001 GUI software as described in the document „GUI Interface“ and connect the sensor to your computer.
If you use the iSYS-4001 the first time InnoSenT recommends to use one of the available configuration files to set up the
sensor.
The DEFAULT setting of the sensor when powered up for the first time is the „Short Range“ configuration.
The following configuration files are available @ www.InnoSenT.de (Services -> Downloads)
• Short Range.ipf (for short range applications up to 50m)
• Long Range.ipf (for long range applications up to 150m)
• Demonstrator.ipf (for testing the sensor in house)
Examples how to mount the sensor and the expected detection fields are given on the next pages.

iSYS-4001 | quick-start guide www.InnoSenT.de
5
Experience and Reliability in Radar-Technology - www.InnoSenT.de
configuration settings
The following settings apply for the different configuration sets:
Short Range.ipf Long Range.ipf Demonstrator ipf
output1 approaching & receding
active low, if object exist
active high, if NO object exist
approaching & receding
active low, if object exist
active high, if NO object exist
approaching & receding
active low, if object exist
active high, if NO object exist
output 2 approaching
active high, if object exist
active low, if NO object exist
approaching
active high, if object exist
active low, if NO object exist
approaching
active high, if object exist
active low, if NO object exist
output 3 approaching
active high, if object exist
active low, if NO object exist
approaching
active high, if object exist
active low, if NO object exist
approaching
active high, if object exist
active low, if NO object exist
rising delay 375ms 375ms 75ms
falling delay 75ms 75ms 75ms
filter type highest amplitude highest amplitude highest amplitude
single target filter 20% for all outputs 20% for all outputs 20% for all outputs
amplification 20dB 20dB 20dB
distance range 0....50m 0....150m 0....50m
detection level 0dB 0dB 25dB

iSYS-4001 | quick start guide
www.InnoSenT.de
6www.InnoSenT.de - Experience and Reliability in Radar-Technology
short-range configuration
Load the file „Short Range.ipf“ in the iSYS-4001 GUI and mount the sensor as described in the following:
• mounting height: 2.2m
• mounting angle: 30° - 45° - 60° (depending on your application)
In the short Range configuratoin the ambiguity range is set to 50m.
Typical detection fields for a person are shown beside.
This configuration is supposed to use in applications like:
• door openers
• mobile traffic lights
• security applications
For application were longer detection ranges are necessary use the „Long Range“ configuration.

iSYS-4001 | quick-start guide www.InnoSenT.de
7
Experience and Reliability in Radar-Technology - www.InnoSenT.de
short-range configuration - detection fields
The schematic below shows typical detection areas for the iSYS-4001 for persons.
The detection areas are based on real measurements but can differ for objects with different RCS.
1m 5m
5m
10m 15m 20m 25m
5m 10m 15m 20m 25m
5m 10m 15m 20m 25m
5m 10m 15m 20m 25m
h=2.2m
h=2.2m
h=2.2m
γ=60°
γ=45°
γ=30°

iSYS-4001 | quick start guide
www.InnoSenT.de
8www.InnoSenT.de - Experience and Reliability in Radar-Technology
long-range configuration
Load the file „Long Range.ipf“ in the iSYS-4001 GUI and mount the sensor as described in the following:
• mounting height: 1.1m
• mounting angle: 90°
In the „Long Range“ configuratoin the ambiguity range is set to 150m.
This configuration is supposed to use in applications like:
• traffic monitoring
• collision avoidance systems
The typical detection distance for cars is shown below.
20m 40m 60m 80m 100m 120m
h=1.1m
The maximum detction distance is depending on the size of the car, typically a detection distance of 100m with an medium
size car can be achieved. For bigger vehicles even larger distances are possible.

iSYS-4001 | quick-start guide www.InnoSenT.de
9
Experience and Reliability in Radar-Technology - www.InnoSenT.de
5m 10m 15m 20m 25m 50m
h=2.2m
γ=60°
γ=45°
γ=30°
5m 10m 15m 20m 25m 50m
h=2.2m
5m 10m 15m 20m 25m 50m
h=2.2m
5m 10m 15m 20m 25m 50m
h=2.2m
γ=60°
γ=45°
γ=30°
5m 10m 15m 20m 25m 50m
h=2.2m
5m 10m 15m 20m 25m 50m
h=2.2m
long-range configuration - typical detection distances for cars
To get an impression about the typical detection range of the iSYS-4001 real measurements were performed. The pictures
below shows the typical detection areas for cars for different mounting situations (mounting height 2.2m - mounting angle
30° - 45° - 60°) of the sensor. To achieve similar results use config file „Long Range.ipf“ available @ www.innosent.de.
30°
45°
60°
30°
45°
60°

iSYS-4001 | quick start guide
www.InnoSenT.de
10 www.InnoSenT.de - Experience and Reliability in Radar-Technology
open Tab „Detection“
install the iSYS-4001
in your environment
iSYS-4001
QUICK-START
connect sensor with your PC
and supply voltage
start iSYS-4001 GUI
and connect to sensor
adjust „Threshold“ in that way
that the FFT peaks
are above the threshold
(function only available if
„Live-View“ is stoped)
select the „Line Filter“ option
if there are fixed frequency
disturbing sources around
open window
„Output Configuration“
individual configuration - flow chart
now you are
ready to start
activate „Show Histogram“
to watch signals over time select distance- and speed
area, as well as the direction
of speed
Tabla de contenidos