Infinite Transtector DCPDU2B Series Manual de usuario

Installation Manual
© 2021 Innite Electronics, Inc. Transtector is a registered trademark of Innite Electronics, Inc. | DCPDU2B-M Rev. 1
DCPDU2B Series Power Distribution Units

Installation Manual | DCPDU2B Series Power Distribution Units
2+1 (208) 635-6400 | www.transtector.com
REV DESCRIPTION CHK’d & APPR’d / DATE
1 Production Release DR / 01-29-21
Contents
1.0 INTRODUCTION...............................................................................................................4
2.0 FEATURES........................................................................................................................4
3.0 PRODUCT LINE................................................................................................................5
4.0 SAFETY & INDUSTRY STANDARDS...............................................................................6
5.0 WARRANTY (summary)....................................................................................................6
6.0 DESCRIPTION OF OPERATION......................................................................................7
7.0 SPECIFICATIONS.............................................................................................................8
8.0 FRONT PANEL DESCRIPTION ........................................................................................8
9.0 BACK PANEL DESCRIPTION...........................................................................................9
10.0 UNPACKING AND INSPECTION ....................................................................................13
11.0 INSTALLATION................................................................................................................14
13.0 SETUPAND TESTING....................................................................................................18

3
+1 (208) 635-6400 | www.transtector.com
FIGURES
Figure 1. DCPDU2B DC Power Distribution Panel........................................................................4
Figure 2. Block Diagram..................................................................................................................7
Figure 3. Front Panel View.............................................................................................................8
Figure 4. Back Panel View..............................................................................................................9
Figure 5. Input Bus Bar Detail........................................................................................................9
Figure 6. Output Barrier Strip Detail............................................................................................10
Figure 7. Alarm Connection Detail...............................................................................................11
Figure 8. Form-C Relay Schematic ..............................................................................................11
Figure 9. Chassis Ground Connection..........................................................................................12
Figure 10. Series Connection of Multiple Panels .........................................................................14

Installation Manual | DCPDU2B Series Power Distribution Units
4+1 (208) 635-6400 | www.transtector.com
OPERATING MANUAL
DCPDU2B SERIES DC POWER DISTRIBUTION PANELS
1.0 INTRODUCTION
DCPDU2BSeries circuitbreakerpanels providedistributionand overloadprotectionfor 1to20 circuits
with circuit breakers that can be eld installed/exchanged using a supplied puller tool. The panels
are only two mounting positions (3.5 inches) high.
The panels provide up to 20 breakers single bus 450A or 10A+10B 450A+450A distribution and
alarm capabilities. The A and B sections of the dual-bus panel are fully isolated, can be separately
congured for 24/48 volts and are polarity neutral. Breaker capacities range from 2.5 to 200 amperes.
Breaker alarm is indicated by a dual color LED (green/red) and Form C relay contacts for each bus.
Figure 1. DCPDU2B DC Power Distribution Panel
2.0 FEATURES
48/24V Tapered entry for easy insertion
POLARITY NEUTRAL NO or NC alarm contacts
450A bus bar inputs Alarm LEDs
Single or Dual Feed Power Fail form-C alarm
Rear panel safety cover standard 19” & 23” mounting brackets

5
+1 (208) 635-6400 | www.transtector.com
3.0 PRODUCT LINE
3.1 Congurations
The following table lists the 5 available congurations of the DCPDU2B series.
STANDARD DUAL FEED CONFIGURATIONS
MODEL
NUMBER VOLTS
EACH FEED INPUT
FEEDS MAX. #
BREAKERS AMPS
EACH FEED TOTAL
AMPS
DCPDU2B-D-2X10-450 48/24 - 48/24 2 10 A side
&
10 B side 450 900
OPTIONAL SINGLE FEED CONFIGURATIONS
MODEL
NUMBER VOLTS
EACH FEED INPUT
FEEDS MAX. #
BREAKERS AMPS
EACH FEED TOTAL
AMPS
DCPDU2B-S-X20-450 48/24 1 20 450 450
3.2 Available Breakers1
AMPS PART NUMBER AMPS PART NUMBER
2.5 DCBKR2B-2.5 50 DCBKR2B-50
5 DCBKR2B-5 60 DCBKR2B-60
10 DCBKR2B-10 80 DCBKR2B-80
15 DCBKR2B-15 100 DCBKR2B-100
20 DCBKR2B-20 1252 DCBKR2B-125
25 DCBKR2B-25 1502 DCBKR2B-150
30 DCBKR2B-30 2002 DCBKR2B-200
40 DCBKR2B-40
NOTES:
1. Breakers need to be ordered individually and are shipped separately.
2. Require two positions. Includes paralleling bars to connect output load terminals.
3. Breakers are magnetic-hydraulic plug-in type with auxiliary contacts (Normally Open) and mid-trip
function. Only the following types may be installed.
2.5A to 100A:
CBI D-Frame Series single pole,
D-2A23XANBSXXXXLXB-XXXXXWDVAX2-X
or
Carling C-Series Handle single pole, CT1-B2-14-XXX-A11-MJ
125A to 200A:
CBI D-Frame Series, parallel pole,
D-2A23XBNBSXXXXLAM-XXXXXWDVAX3-X
or
Carling C-Series Handle Parallel pole, CT2-P2-04-XXX-A11-MK

Installation Manual | DCPDU2B Series Power Distribution Units
6+1 (208) 635-6400 | www.transtector.com
4.0 SAFETY & INDUSTRY STANDARDS
4.1 DCPDU2B Series power distribution panels meet the following safety requirements:
STANDARD
UL60950-1, 2nd Edition
CSA22.2 No. 60950-1, 2nd Edition
EN60950-1, 2nd Edition
4.2 DCPDU2B Series power distribution panels are CE marked to indicate conformance
to the European Union’s Low Voltage Directive.
4.3 These Distribution Panels operate at voltages that could potentially be hazardous.
Furthermore, inadvertent short circuiting of the system battery and/or rectier by mis-
connection or other error could be harmful. This product should be handled, tested
and installed only by qualied technical persons who are trained in the use of power
systems and are well aware of the hazards involved.
4.4 When operating this Distribution Panels the chassis ground terminal must be
connected to the system frame ground or other proper safety ground for the protection
of personnel.
4.5 Allconnectionsto theDistributionPanelsshould becarefullychecked forerrorsbefore
applying power to them.
4.6 The internal voltages may be at hazardous potentials. The top cover should not be
removed. There are no user-serviceable components in these units. Removing the
top cover will void the warranty.
5.0 WARRANTY (summary)
DCPDU2B Series power distribution panels are warranted for two (2) years from date of
shipment against defects in material and workmanship. This warranty does not extend
to products which have been opened, altered or repaired by persons other than persons
authorized by the manufacturer or to products which become defective due to acts of God,
negligence or the failure of customer to fully follow instructions with respect to installation,
application or maintenance.
For a complete text of Transtector’s warranty conditions please request a copy from your
local Sales Oce.

7
+1 (208) 635-6400 | www.transtector.com
6.0 DESCRIPTION OF OPERATION
6.1 Power Distribution Circuits. A simplied schematic diagram of the distribution
panels is shown in Figure 2. The battery input to each load connects to a high-current
copper bus bar from which the individual fuses or circuit breakers distribute power to
the loads. The return input connects to a similar bus bar to which the individual loads
terminate. The A and B loads are totally independent and isolated with the exception
of models incorporating the ‘S’ option.
CIRCUIT
BREAKERS
BATT.
BATT.
INPUT
RET.
INPUT
RET.
HI-CURRENT BUS BAR HI-CURRENT BUS BAR
HI-CURRENT BUS BAR HI-CURRENT BUS BAR
LOADS LOADS
1 2 3... N
A SIDE
ALARM
CIRCUITS
B SIDE
ALARM
CIRCUITS
A SIDE B SIDE
-S OPTION
-S OPTION
1 2 3... N
Figure 2. Block Diagram
6.2 Alarm Circuits. The alarm circuits detect a tripped circuit breaker and, in this event,
turn on the red part of the LEDs. The alarm circuits also each drive Form C relay
contacts. If one or more circuits open or if there is an input power failure, the relays
are de-energized and the contacts are used to control external audible or visual alarms.
The A and B alarm circuits are also independent and isolated from each other.
LED & RELAY STATE MEANINGS
LED State Relay State Meaning
Green Energized (N.O. is closed) OK
Red De-energized
(N.O. is open) Breaker Trip
OFF No Input Power

Installation Manual | DCPDU2B Series Power Distribution Units
8+1 (208) 635-6400 | www.transtector.com
7.0 SPECIFICATIONS
The following specications are typical at 25°C unless otherwise noted.
INPUT/OUTPUT
Panel Capacity
@35°C..............................................................................450A per Bus
@40°C..............................................................................400A per Bus
@50°C..............................................................................320A per Bus
@70°C..............................................................................200A per Bus
Conguration ..................................450A Single Bus with 1 to 20 Breakers
900A Dual Bus 1 to 10 Breakers Each Bus
Breaker Capacity 1................................................................. 2.5A to 200A
Voltage 1.....................................................................................21-60VDC
Polarity ............................................Neutral, Positive or Negative Ground
ALARMS
Alarm Indicator ....................................................Dual Color LED Per Bus
LED Status Indication........................................................Green = Normal
Red = CB Trip Alarm
O = No Power
Alarm Relays.............................................. Form C Contacts for each Bus
SAFETY.................... UL60950-1 2nd Ed., CSA22.2 No. 60950-1 2nd Ed.,
EN60950-1 2nd Ed.
ENVIRONMENTAL
Operating Temp. Range ..................................................... -10°C to +70°C
Storage Temp. Range........................................................ -40°C to + 85°C
Humidity........................................................ 0% to 95%, Non-Condensing
PHYSICAL SPECIFICATIONS
Case Material ......................................................................................Steel
Finish............................................................................Powder Coat Black
Case Dimensions, Inches (mm) ........................3.45 H x 17.16 W x 5.98 D
(87.6 x 435.9 x 151.9
Weight (approx.)........................................................... 12.5 lbs. (5.67 kg.)
Rack Mounting...................................................................... 19 or 23 Inch
CONNECTIONS
Input Connections...........................................................................Bus Bar
Output Connections...............................................1/4-20 Stud, 2-hole lugs
Chassis Ground Connection..................................1/4-20 Stud, 2-hole lugs
Alarm Relay Connections...................Spring Clamp Terminals,16-26AWG
Notes:
1. See ordering guide to specify.
8.0 FRONT PANEL DESCRIPTION
The front panel of the DCPDU2B, shown in Figure 3 below, consists of the A and B sides
and a center section. The A and B sides can each accommodate up to 10 eld installed/
replaceable hydraulic magnetic circuit breakers rated from 2.5A to 200A. The center section
has two green/red LEDs, one for the A side (left) and the other for the B side (right). At the
bottom of this center section is a slot for a wallet and designator card. This card permits the
recording of each output circuit by number.
A - ALM B - ALM
123456789 10
A BUS - 450A MAX/100A MAX PER CB
123456789 10
B BUS - 450A MAX/100A MAX PER CB
NO-C-NC NO-C-NC
ALM-B
ALM-A
NO-C-NC NO-C-NC
1098765432 1
0.63
(16.0)
0.76
(19.3)
0.42
(10.7)
0.25
(6.4)
1/4-20 stud
length = 0.50 (12.7),
0.625 (15.88) spacing
1/4-20 stud
length = 0.38 (9.7),
0.625 (15.88) spacing
0.57
(14.5)
0.37
(9.4)
0.90
(22.9)
ø 0.306 (7.8)
0.49 (12.5) x
0.31 (7.9) slot
3.50
(88.9)
1.25
(31.8)
5.98
(151.9)
0.60
(15.2)
17.16
(435.9)
0.76
(19.3)
1.725
(43.82)
0.56
(14.2)
0.21
(5.3)
1.13
(28.7) 0.22
(5.6)
3.45
(87.6)
A - BUS OUTPUT FEEDB - BUS OUTPUT FEED
A - BUS RETURNB - BUS RETURN
B - BUS FEED BREAKERS
A - BUS FEED BREAKERS
Alarm connector
Chassis GND
(1/4-20 THREAD)
A - BUS INPUT
FEED
B - BUS INPUT
FEED
1098765432 1
Shorting Bus (-S Models)
OUTLINE OF SAFETY COVER
(blue dotted line)
4.60
(116.8)
0.625
(15.88)
0.500
(12.70)
0.750
(19.05)
4.642
(117.91)
Figure 3. Front Panel View

9
+1 (208) 635-6400 | www.transtector.com
9.0 BACK PANEL DESCRIPTION
9.1 Back View. Figure 4 shows the back of the DCPDU2B distribution panel. Inputs are
at the left and right ends of the back panel. Side B outputs are at two rows of barrier
terminal strips on the left side, and side A outputs are the same on the right side.
At the center of the back panel are two spring clamp terminal blocks for the Form C
relay contact outputs.
Below these is a chassis ground terminal.
A - ALM B - ALM
123456789 10
A BUS - 450A MAX/100A MAX PER CB
123456789 10
B BUS - 450A MAX/100A MAX PER CB
NO-C-NC NO-C-NC
ALM-B
ALM-A
NO-C-NC NO-C-NC
1098765432 1
0.63
(16.0)
0.76
(19.3)
0.42
(10.7)
0.25
(6.4)
1/4-20 stud
length = 0.50 (12.7),
0.625 (15.88) spacing
1/4-20 stud
length = 0.38 (9.7),
0.625 (15.88) spacing
0.57
(14.5)
0.37
(9.4)
0.90
(22.9)
ø 0.306 (7.8)
0.49 (12.5) x
0.31 (7.9) slot
3.50
(88.9)
1.25
(31.8)
5.98
(151.9)
0.60
(15.2)
17.16
(435.9)
0.76
(19.3)
1.725
(43.82)
0.56
(14.2)
0.21
(5.3)
1.13
(28.7) 0.22
(5.6)
3.45
(87.6)
A - BUS OUTPUT FEEDB - BUS OUTPUT FEED
A - BUS RETURNB - BUS RETURN
B - BUS FEED BREAKERS
A - BUS FEED BREAKERS
Alarm connector
Chassis GND
(1/4-20 THREAD)
A - BUS INPUT
FEED
B - BUS INPUT
FEED
1098765432 1
Shorting Bus (-S Models)
OUTLINE OF SAFETY COVER
(blue dotted line)
4.60
(116.8)
0.625
(15.88)
0.500
(12.70)
0.750
(19.05)
4.642
(117.91)
Figure 4. Back Panel View
9.2 Input Connections. See Figure 5. The DC power inputs to the distribution panel
are made by means of crimp type lugs to two copper bus bars on side A and side B.
The upper bus bar is the battery connection (whether + or -) and the lower bus bar
is the return (whether + or -).
0.37
(9.4)
0.90
(22.9)
ø
0.306 (7.8)
0.49 (12.5) x 0.31 (7.9) slot
0.76
(19.3)
1.12
(28.4)
0.56
(14.2)
1.13
(28.7)
Figure 5. Input Bus Bar Detail

Installation Manual | DCPDU2B Series Power Distribution Units
10 +1 (208) 635-6400 | www.transtector.com
9.3 Recommended Input Cable Sizes and Lugs
The following table details the recommended cable size for various input current.
MAXIMUM
CURRENT CONDUCTOR
SIZE PANDUIT CORP.
PART NUMBER TORQUE
1/4 x 20 BOLT
450A 350KCMIL LCC350-14BW-X 62 in-lbs
400A 300KCMIL LCCX250-14B-X 62 in-lbs
320A 4/0 AWG LCCX4/0-14B-X 62 in-lbs
200A 3/0 AWG LCCX3/0-14B-X 62 in-lbs
150A 1/0 AWG LCCX1/0-14B-X 62 in-lbs
9.4 Output Connections. Output connections for A and B loads are shown in Figure 4.
There are 10 sets of bus bar terminals for each side, Aand B. The connections are
numbered to correspond with the numbers of the front panel breakers. The upper
strip connections are from the battery (FEED) through the breakers; the lower strip
connections are the RETURNS. Side B is on the left and side A on the right when
viewed from the rear.
All connections use 1/4-20 threaded studs and are rated up to 100 amperes. Maximum
wire size is 2 AWG. Transtector recommends using FLEX wire with either Panduit
LCDXN2-14A-E or LCDXN2-14AF-E (90deg angle) lugs. When 125A, 150A or 200A
breakers are installed two positions are utilized. Figure 6 below shows detailed
spacing of the terminals.
A - ALM B - ALM
123456789 10
A BUS - 450A MAX/100A MAX PER CB
123456789 10
B BUS - 450A MAX/100A MAX PER CB
NO-C-NC NO-C-NC
ALM-B
ALM-A
NO-C-NC NO-C-NC
1098765432 1
0.63
(16.0)
0.76
(19.3)
0.42
(10.7)
0.25
(6.4)
1/4-20 stud
length = 0.50 (12.7),
0.625 (15.88) spacing
1/4-20 stud
length = 0.38 (9.7),
0.625 (15.88) spacing
0.57
(14.5)
0.37
(9.4)
0.90
(22.9)
ø 0.306 (7.8)
0.49 (12.5) x
0.31 (7.9) slot
3.50
(88.9)
1.25
(31.8)
5.98
(151.9)
0.60
(15.2)
17.16
(435.9)
0.76
(19.3)
1.725
(43.82)
0.56
(14.2)
0.21
(5.3)
1.13
(28.7) 0.22
(5.6)
3.45
(87.6)
A - BUS OUTPUT FEEDB - BUS OUTPUT FEED
A - BUS RETURNB - BUS RETURN
B - BUS FEED BREAKERS
A - BUS FEED BREAKERS
Alarm connector
Chassis GND
(1/4-20 THREAD)
A - BUS INPUT
FEED
B - BUS INPUT
FEED
1098765432 1
Shorting Bus (-S Models)
OUTLINE OF SAFETY COVER
(blue dotted line)
4.60
(116.8)
0.625
(15.88)
0.500
(12.70)
0.750
(19.05)
4.642
(117.91)
Figure 6. Output Barrier Strip Detail
The following table lists a range of cable sizes with matching lugs that will t the output
terminals. The indicated current rating is the maximum assuming that the cables are
bundled/conned.