IMC MR60 Manual de usuario

MR60 GLASS FROSTERS
INSTALLATION AND OPERATING MANUAL
PLEASE LEAVE WITH OPERATOR
MR60 Glass Froster
Series 1
Imperial Machine Company Limited
Unit 1, Abbey Road
Wrexham Industrial Estate
Wrexham LL13 9RF
Tel: +44 (0)1978 661155
Fax: +44 (0)1978 729990
Service Fax: +44 (0)1978 667766
Spares Fax: +44 (0)1978 667759
E-mail: info@imco.co.uk
Website: www.imco.co.uk
A34/100 R1 ECN 8848 May 2019

MR60 –GLASS FROSTER 2
EC DECLARATION OF CONFORMITY
(Guarantee of Production Quality)
We, Imperial Machine Company Limited of:
Unit 1, Abbey Road, Wrexham Industrial Estate, Wrexham, LL13 9RF
Declare under our sole responsibility that the following products
MR60
as described in the attached technical documentation, are in conformity with the protection
requirements of the Electromagnetic Compatibility Directive 2014/30/EU and manufactured in
accordance with harmonised standards EN 61000-6-1: 2001 Immunity and EN 61000-6-3: 2007
Emissions (plus product specific standards).
They also satisfy the essential health and safety requirements of the Low Voltage Directive
2014/95/EC and are manufactured in accordance with standards BS EN 60335-1 and BS EN
60335-24, and the relevant requirements of the Pressure Equipment Directive 2014/68/EU.
Approved by : E.Plumb, Engineering Manager -
Date: May 2019

MR60 –GLASS FROSTER 3
INDEX
INDEX ................................................................................................................... 3
WARRANTY ......................................................................................................... 4
DELIVERY ............................................................................................................ 4
SAMPLE RATING LABEL.................................................................................... 5
INTRODUCTION................................................................................................... 5
INSTALLATION .................................................................................................... 7
TURNING LED LIGHTS ON-OFF ......................................................................... 8
CHANGING AN LED LIGHT FITTING.................................................................. 9
ELECTRICITY SUPPLY CONNECTION............................................................. 10
COMMISSIONING .............................................................................................. 10
CHANGING THE CONTROLLER SET POINT ................................................... 11
USING YOUR GLASS FROSTER ...................................................................... 11
CLEANING.......................................................................................................... 12
CHANGING SHELF POSITION .......................................................................... 12
MAINTENANCE.................................................................................................. 13
DO’S AND DON’TS ............................................................................................ 14
ORDERING SPARE PARTS............................................................................... 15
END OF LIFE DISPOSAL................................................................................... 15
MATERIAL CONTENT........................................................................................ 15
WIRING DIAGRAM............................................................................................. 16
SPARES LIST DRAWING 1 ............................................................................... 17
SPARES LIST DRAWING 2 .............................................................................. 18
SPARES LIST..................................................................................................... 19
NOTES................................................................................................................ 20

M
R60
–
GLASS FROSTER
4
WARRANTY
These Glass Froster’s are guaranteed by IMC for 2 years from the date of
purchase from IMC, or from one of its stockists, dealers or distributors. The
guarantee is limited to the replacement of faulty parts or products and excludes
any consequential loss or expense incurred by the purchaser. Defects which
arise from faulty installation, inadequate maintenance, incorrect use, connection
to the wrong electricity supply, or fair wear and tear, are not covered by the
guarantee.
The guarantee applies in this form to installations within the United Kingdom.
Export units carry 2 years “parts only”warranty.
Please observe these instructions carefully.
DELIVERY
The packaged machine consists of:
MR60 Glass Froster containing:
Shelf (Full size)
Shelf (base ½ size)
Shelf clips
Sets of keys
2
1
8
2
Instruction Booklet 1
Please notify both the carrier and the supplier within three days of receipt if
anything is missing or damaged.
Check that the correct machine has been supplied and that the voltage, marked
on the rating plate, is suitable for the supply available. The rating plate is
located internally on the right hand side of the unit.

M
R60
–
GLASS FROSTER
5
SAMPLE RATING LABEL
INTRODUCTION
The MR60 range is a back-bar or under-bar glass froster designed for the
frosting and storage of glasses.
The following quantity of standard pint glasses can be held in each unit:
Glass Froster Capacity
(Standard Pint Size Glass)
MR60 (900h x 600w x 500d)
MR60 (800h x 600w x 500d)
50
50

M
R60
–
GLASS FROSTER
6
MR60 Dimensions:
MODEL
X
Y
M
R
60
900mm
500
900
M
R
60 8
0
0
mm
500
8
0
0
X mm
Y mm
600mm
M
R60

M
R60
–
GLASS FROSTER
7
INSTALLATION
For the Installer
These Instructions contain important information designed to help the user
obtain the maximum benefit from their investment in an IMC VR60 Glass
Froster.
Please read them carefully before starting work, and consult with the supplier in
the event of any queries.
Be sure to leave this Instruction Manual with the user after installation of the
machine is complete.
Procedure
WARNING
The following table shows the weight and the minimum quantity of
people required to lift each unit:
Glass Froster Net Weight Quantity of
People
MR60 (all variants) 57.5 kg (max) 2
Install the unit on a flat and level floor.
Ensure a minimum 10mm clearance to either side of the unit, there is to be
a 20mm clearance at the top and 60mm clearance at the back.
Do not install the unit close to a heat source such as a radiator or a warm air
outlet.
Ensure that the unit is standing level by adjusting the feet on the base of the
unit.
The unit has an automatic defrost cycle and evaporates all the condensate
water without the need for a drainage system.
NOTE!
It is important to install the Glass Froster on a flat surface. This
ensures that the doors are level. Adjustment is provided via the
feet, to enable the installer to level the cabinet. Engineer Call-
outs in order to level Glass Frosters, will not be covered under
warranty.

M
R60
–
GLASS FROSTER
8
TURNING LED LIGHTS ON-OFF
The cabinet is illuminated by a LED light unit, this light can be turned on or off
by depressing the switch that is located on the underside of the worktop.
To access this switch the door must be opened
When the switch is flush the lights are on.
Light Switch

M
R60
–
GLASS FROSTER
9
CHANGING AN LED LIGHT FITTING
The cabinet interior is illuminated by a LED light strip fitting located at the front
of the top inner panel.
To change the light assembly:
·Ensure the mains power to the unit has been turned off.
·Open the front cabinet door(s).
·Unscrew the screws holding the LED assembly in place.
·Carefully lower the LED assembly down and disconnect the 2 wires from the
unit.
·The LED light assembly should now be free to fully remove from the unit.
·To fit the replacement unit.
·Place the new LED light assembly inside the unit, re connect the 2 wires
from the unit to the new LED light assembly.
·Re fit the LED light assembly inside the unit by using the screws.
·Re-connect the mains power and ensure the light illuminates by means of
the switch.
Fixing
Screw
s
LED Light
Assembly
crews
LED Light
Assembly
ews

M
R60
–
GLASS FROSTER
10
ELECTRICITY SUPPLY CONNECTION
Position the unit in the chosen site. The electricity supply connection should be
made to a power outlet socket or isolator mounted on the wall close to the
machine. This socket or isolator must be accessible once the machine is
installed. Before connecting, check that the voltage shown on the rating label is
correct for the electricity supply you have available. If the plug does not fit your
sockets or a longer lead is required, changes must be made by an approved
electrician.
NOTE: The plug is fitted with a 10amp fuse.
The plug fuse cover must be refitted when changing the fuse. In the event of
losing the fuse cover the plug must NOT be used until a replacement fuse cover
has been obtained and fitted or the plug replaced.
WARNING: This machine must be earthed
Should the supply cord become damaged then a replacement must be fitted by
an approved electrician. The IEE Codes of Practice must be observed.
The wires in the mains lead are coloured in accordance with the following code
Green and yellow Earth
Blue Neutral
Brown Live
COMMISSIONING
Before using a bottle cooler for the first time, the interior should be wiped out
with a clean damp cloth.
Allow the machine to stand for 1 hour to allow the refrigerant to settle. Plug in
and switch on at the wall socket. There is no separate switch to turn on the
machine. The compressor will start running less than one minute after the
supply is switched on.
Check that the light is working.
Run the unit empty, and check that cold air is being circulated within the
cabinet.