1 - INTRODUCTION
1
Please read and understand this manual before you install the equipment.
We are very pleased that you specified this IMAX product.
When we designed the product our aim was that it should be to the entire satisfaction of the
user.
Therefore, and to ensure optimum performance and a long trouble free service life, IMAX
manufactured the Product to the highest engineering standards.
The design of the product is based on many years of experience in the field of Marine Lighting,
it is made to withstand the environmental conditions in both offshore and inshore.
In order to maintain the quality standard of the equipment, we strongly recommend to use
original IMAX spares whenever any part should be replaced, just to ensure and to prolong
service life and performance.
A spare parts list is attached to this manual.
Always quote Product Serial Number in case there is a need to contact IMAX B.V. regarding the
equipment.

2
-
SAFETY PRECAUTIONS
2
To create a safe working environment and safety of the user, the instructions given hereunder must be
strictly adhered to :
ATTENTION : In order to prevent personal injury or damage to the searchlight, when unpacking or
manoeuvring the unit into its final position, suitable lifting points must be used.
!
Prevent rain, snow, condensation and water droplets from contacting the lamp as this may
cause bulb failure and possible shattering.
!
Quartz halogen bulbs run with a high pressure in excess of atmospheric.
Whilst the construction is inherently strong, there is a slight risk of the bulb shattering.
!
Never look directly into an illuminated searchlight as this may cause severe damage to eyesight. If it is
necessary to inspect a lamp whilst in operation, always wear suitable protective goggles.
!
Should it be necessary to examine the lamp with the front bezel removed, always use a protective shield
and wear goggles to ensure a safe working environment.
!
Searchlights get very hot. Never touch the unit when lit. Always allow it to cool down for 15 to 20
minutes after it has been switched off.
!
Never place anything on or cover the searchlight when in use.
!
Ensure the lamp has cooled sufficiently before removal.
!
If excessive force appears to be n
ecessary to remove the lamp, the equipment should be inspected by a
competent person or contact the manufacturer
!
When breaking a lamp for disposal, care must be taken to ensure the glass fragments are safely
contained. This operation must be performed out of doors in free air. In all circumstances refer to the
lamp manufacturer instructions packed with the lamp.
!
Due to the vast range of lamps available it may appear possible that more powerful lamps can be used
in the equipment than it was designed for. Even when the unit physically accept a higher wattage or
voltage lamp, this substitution is not recommended and it is dangerous. This action will also void any
warranties on the equipment.
Always refer to the lamp manufacturers technical data when dealin
g with lamps.

3
3 - TECHNICAL INFORMATION
The searchlight IM490RC has the following features :
•All marine grade materials and fixings
•Parabolic silvered glass mirror/reflector
•Epoxy powder coatings
•Pan movement 360
o
•Tilt movement +30
o
to –30
o
•Pan speed 12
o
/sec
•Tilt speed 2.4
o
/sec
•Operating temp. –30
o
to +70
o
•Remote focus facility (optional)
•Internal thermostatically controlled heater (75Watt)
•Toughened heat resistant front glass
Optical data for the IM490RC :
1000W T/H 2000W T/H
•Supply voltage 115/230V 115/230V
•Peak Beam Candle Power 2.098.000 cd 2.748.300 cd
•Range 1.448 mtr 1.657 mtr
•Divergence 5
o
– 8
o
5
o
– 8
o
•Operational temperature -30 to + 70
o
C -30 to + 70
o
C
In order that the searchlight operates correctly it is imperative that competent personnel are
responsible for the installation, operating and servicing of this equipment, Failure to adhere to
this advice may cause premature failure or incorrect operation of the searchlight, which may
damage the equipment or cause personal injury.

4 - PRE-INSTALLATION INSTRUCTIONS
4
In case the equipment is to be stored for a relatively long period of time, care must be taken for
a clean and dry environment.
In case the unit has been in storage for several months it is advised to conduct a routine
maintenance check before it is installed in its definite position.
SAFETY :
Do not connect the searchlight to an electrical supply before being installed.
Please take care of a safe working environment to avoid damage and personal injury.

5 – ELECTRICAL INSTALLATION
5
The electrical installation of the equipment should be performed by competent personnel
in accordance with current Electrical Installation Rules and Standards.
It is essential that full operating voltage is applied to the lampholder in order to obtain
maximum performance of the lightsource.
Method of Electrical Connection :
!! Disconnect the supply before working on the electrical system
!! The electrical supply must be properly fused
!! To obtain full voltage supply on the lampholder terminals, provisions must be
made in cables of a suitable diameter.
!!! THE EQUIPMENT MUST BE EARTHED

6 - DIAGRAMS and Assembly drawings
6
Drawing number :
IM08095 - Wiring diagram, single panel control
IM08096 - Wiring diagram, single panel control + optional focus control
IM08097 - Wiring diagram, multi panel control with Electronic Interlocking
IM400-111 Outline Joystick Control Panel
General outline IM490RC
Tabla de contenidos