IMAGE SYSTEMS XLED-2MPC Manual de usuario


Specications and features are subject to change without notice. Images shown are for illustrative
purpose only. All names of the products are trademarks or registered trademarks of their respective
companies. 2013.10. Ver 1.0


1
Safety Symbol
This manual uses the safety symbols below. They denote critical information. Please
read them carefully.
WARNING
Failure to abide by the information in WARNING may result in serious injury
or life threatening.
CAUTION
Failure to abide by information in CAUTION may result in moderate injury
and/or property or product damage.
ATTENTION
Consult accompanying documents.
The lighting ash with arrowhead symbol in an equilateral triangle, is
intended to alert the user to the presence of un-insulated “Dangerous
Voltage” within the product’s enclosure that of many sufcient magnitude
to constitute a risk of electric shock to persons.
Stand-by Switch. Press to turn the monitor on or off (Stand-by mode).
Diagonal line in circle indicates a prohibited action.
Protective earth(ground).
Fragile.
Handle with care.
Alternating current.
Direct Current.

XLED-3MPC_XLED-2MPC USER’S MANUAL
SN Serial Number
Indicates the manufacturing date
Follow instructions for use
● Power supplied equipment can emit electromagnetic waves, which could inuence,
limit or result in malfunction of the monitor. Please install the equipment in a
controlled environment where such effects are avoided.
● These XLED-3MPC and XLED-2MPC monitors are intended for use in medical image
system environment but does not support the display of mammography images for
diagnosis. For the diagnosis of mammography digital images, please contact your
local sales representative.
● Product specications may vary depending on the sales region. Please conrm the
specications within the manual.

3
Table of Contents
Safety Symbol ----------------------------------- 1
Environmental Information ----------------------------------- 4
Safety Introductions ----------------------------------- 5
FCC Information ----------------------------------- 7
VCCI Class B ITE ----------------------------------- 8
PRECAUTIONS ----------------------------------- 9
CAUTION ----------------------------------- 13
Notice ----------------------------------- 15
Introduction ----------------------------------- 16
Installation ----------------------------------- 20
Making use of USB (Universal Series Bus) ----------------------------------- 29
Monitor Specications ----------------------------------- 31
Mechanical Specication and Regulatory ----------------------------------- 33
Power Management ----------------------------------- 35
Trouble shooting ----------------------------------- 36

XLED-3MPC_XLED-2MPC USER’S MANUAL
Environmental Information
Disposal Information
This product consists of devices that may contain mercury, which must be recycled or
disposed of in accordance with local, state, or country laws (within this system, the
backlight lamps in the monitor display contain mercury). This equipment has required
the extraction and use of natural resources for its production. It may contain hazardous
substances for health and environment. In order to avoid the dissemination of those
substances in the environment and to diminish the pressure on natural resources, we
encourage you to use the appropriate take-back systems. Those systems will reuse or
recycle most of the materials of your end-of-life equipment in a sound way.
The crossed-out wheeled bin symbol invites you to use those systems. If
you need more information on the collection, reuse and recycling systems,
please contact your local or regional waste administrator. You can also
contact our nearest representative ofce for more information on the
environmental performances or disposal of our products.
Cleaning
The screen is made of thin glass with a plastic front surface and can be damaged if
dropped, hit or scratched. Do not clean the front panel with keton-type materials (e.g.,
acetone), ethyl alcohol, toluene, ethyl acid, methyl, or chloride-these may damage the
panel.
● Panel: Clean with a soft woolen or cotton towel. Use a watery solution or a mild
commercial glass cleaning solution.
● Cabinet: Clean with a soft cloth dampened with mild detergent and water. Repeat
this with water only and wipe dry with a dry cloth.
Repacking
Do not throw away the carton and packing materials. We encourage you to keep them
for future use in the case of returning the product for replacement or repair. This ideal
package is specially designed and is not easy to nd.

5
Safety Introductions
General Recommendations
Read the safety and operating instructions before operating the display.
Retain safety and operations for future reference.
Adhere to all warnings of this display and in the operating instructions manual.
Follow all instructions for operation and use.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVERTISSEMENT RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
LCD MONITOR
54IJ
E217340
WITH RESPECT TO ELECTRIC SHOCK,
FIRE AND MECHANICAL HAZARDS ONLY
IN ACCORDANCE WITH UL60601-1 AND
CAN/CSA C22.2 NO. 601.1,
MEDICAL EQUIPMENT CERTIFIED FOR CANADA
Grounding Reliability Can Only Be Achieved When The Equipment ls Connected
To An Equivalent Receptacle Marked “Hospital Only” or “Hospital Grade”
When the unit is used together with other equipment in the patient area, the equipment
shall be connected according to Standard UL60601-1 and IEC60601-1.

XLED-3MPC_XLED-2MPC USER’S MANUAL
Classication
● Protection against electric shock: Class I Equipment.
● Degree of protection against electric shock: No applied parts.
● Degree of protection against the ingress of water: ordinary IPX0.
● Degree of safety in the presence of ammable anesthetics mixture with air or with
oxygen or with nitrous oxide: Not suitable for use in the presence of ammable
anesthetics mixture with air or with oxygen or with nitrous oxide.
This equipment has been tested and found to comply with the limits for medical
devices to the IEC 60601-1-2:1994. These limits are designed to provide reasonable
protection against harmful interference in a typical medical installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to other devices in the
vicinity. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to other devices, which
can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures :
● Reorient or relocate the receiving device.
● Increase the separation between the equipment.
● Connect the equipment into an outlet on a circuit different from that to which the
other device(s) are connected.
● Consult the manufacturer or eld service technician for help.

7
FCC Information
1. User Instructions
The Federal Communications Commission Radio Frequency Interference Statement
includes the following warning:
NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television receptions, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
● Reorient or relocate the receiving antenna.
● Increase the separation between the equipment and receiver.
● Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
● Consult a local dealer.
User Information
Changes or modications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment. If necessary, consult your
dealer or an experienced radio/television technician for additional suggestions. You may
nd the booklet called How to identify and Resolve Radio/TV Interference problems
helpful. This booklet was prepared by the Federal Communications commission. It
is available from the U.S. Government Printing Ofce, Washington, DC 20402, Stock
Number 004-000-00345-4.
User must use shielded signal interface cables to maintain FCC compliance for the product.
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Monitor de IMAGE SYSTEMS