IKUSI TNS-101 Manual de usuario

TNS-101 (Ref. 5114)
FTA or MultiCrypt DVB-T ➞➞
➞➞
➞IP Streamer — Common Interface
Configuration and Settings
User Manual
Television on IP Networks

Configuration and Setting of the TNS-101 Streamer Module
June 2009
Revision A
IKUSI - Ángel Iglesias, S.A.
Paseo Miramón, 170
20009 San Sebastián
SPAIN
Tel.: +34 943 44 88 00
Fax: +34 943 44 88 11
www.ikusi.com
User Manual
EN

CONTENTS
Introduction ............................................................................................................................. 4
This Manual ................................................................................................................. 4
Product Description...................................................................................................... 4
Chapter One - Configuration of the TNS-101 Streamer .......................................................... 5
Configuration.......................................................................................................... 6 -10
Save/Restore Configuration ....................................................................................... 11
General Report .......................................................................................................... 12
Chapter Two - TNS-101 Streamer Settings .......................................................................... 13
Input Settings ............................................................................................................. 14
Output Settings ..................................................................................................... 15-17
SAP Channel Settings ............................................................................................... 18
CAM User Menu ........................................................................................................ 19
SNMP Cofguration ................................................................................................ 20/21
Chapter Three - TNS-101 Streamer Status Information ....................................................... 22
Status Information ...................................................................................................... 23
Chapter Four - TNS-101 Streamer Reports .......................................................................... 24
Input Services ............................................................................................................ 25
Output Streams .......................................................................................................... 26
System Logs .............................................................................................................. 27
3

4
This Manual
This manual describes the configuration and settings programme for the TNS-101 Streamer Module.
It is the second part of the user documentation for said module, the first part of which is the Installation
and Access manual supplied in paper format.
Product Description
TNS-101 streamers are DVB-T to IP gateways designed to broadcast in multicast the services (TV and Radio
programmes) issued from FTA or encrypted digital terrestrial reception; in case of encrypted signal, a CAM
containing the operator's smart card must fit the front panel slot. The IP streams can be viewed using an IPTV
set-top box or a software video player.
TNS-101 modules have an IKUSI ClassA mechanical format. As such, they are fixed to BAS-700 / BAS-900
baseplates or to an SMR-601 rack frame, and are +12 VDC powered from a CFP module.
Characteristics
●Input: 1 DVB-T transport stream (MPTS). Output: up to 8 simultaneous, IP-encapsulated services (TV programmes), with
individual multicast addresses.
●Information filtering of DVB tables.
●UDP & RTP transmission protocols.
●Web interface for configuration and setting.
●Alarm information SNMP agent.
●SAP & SDP protocols that facilitate automatic service selection on the user's STB and provide information to external servers.
ADVANCED
PID filtering
PSI/SI parsing
Transparent ECM & EMM messaging
PAT and PMT table regeneration
Routing or blocking for CAT, NIT, SDT, EIT, TDT tables
Configurable QoS marking
Configurable Time To Live
Program Access Screen
Introduction
Once the desired programme language has been chosen [Spanish (es), English (en), French (fr) ], enter
the password and click on OK.
Note: The default password — admin — can (and must) be changed as explained on page 9.
When a connection is established between the TNS-101 streamer and the control PC, the programme
access screen will appear:

Chapter One - Configuration of the TNS-101 Streamer
In this Chapter
● Configuration
● Save/Restore
● General Report
5

6
General Configuration
Figure 1.1 - Initial programme screen
Figure 1.2 - Identification card of the Configuration window.
Initial program screen
The first screen that appears
when the programme is
accessed contains the "Output"
window, which gives information
on the IP streams that have
been created on the module and
which may or may not be
incorporated into the output data
stream.
On the left of this screen are the
menus that access all of the
programme's functionalities.
Click on the General menu on the left of the screen to display a dropdown list
containing the 3 options: Configuration, Save/Restore and General Report.
Click on Configuration. The Configuration window will appear :
Identification
The identification card (Figure 1.2) provides basic data on the TNS-101 streamer. The
different card fields are completed as follows:
Configuration

7
"Model": TNS-101. This data cannot be changed.
"Serial Number": Informational data which cannot be changed.
"Firmware Version": As above.
"Identifier": Any name that the installer or operator wishes to assign to the streamer
module can be entered here.
"Location": Enter the postcode of the installation site if required.
"Installer": The installer's identification details can be entered here.
"Contact": Then enter their contact details (telephone number, email).
"Installation date": The date on which the streamer module was installed can be
entered here.
Click on the Save button at the bottom of the window to store the information on the streamer module, this
information is then shown each time the module is accessed.
Configuration

8
Network
Click on the Network tab to configure the streamer's ethernet connection parameters.
The following card is displayed:
Figure 1.3 - Network card of the Configuration window.
"Use DHCP to get IP address": If this box is checked, the TNS-101 module will use
the DHCP protocol for assigning dynamic IP addresses. Consequently, no data
needs to be entered in the next five fields on the tab.
If the administrator of the network on which the TNS headend is installed assigns
static IP addresses, the box will not be checked and the following fields will need to
be filled in.
WARNING: If this option is activated, the IP address assigned to the streamer can
only be known by consulting the DHCP server management system.
"IP Address": Enter the IP address that you wish to assign to the streamer. This
address must fall within the range of local network addresses.
"Network mask": Enter the local network mask.
"Default gateway": Enter the IP address of this gateway. This information is only
required if you want the streamer to access Internet.
"Primary DNS server": Enter the primary server's IP address. Equally, this
information is only required if you want the streamer to access Internet.
"Secondary DNS server": Enter the same information for the secondary server.
"MAC Address": The physical address of the streamer's ethernet network card is
displayed automatically.
Once you have filled in all of the required information, click on Modify Network Configuration. If, at the last moment,
you decide to keep the current settings, click on Restore.
Configuration

9
Password
If you want to change the current access password, click on the Password tab. The
following card is displayed:
Figure 1.4 - Password card of the Configuration window.
"Current password": Enter the current password.
"New password": Enter the new password which will be required to access the
program the next time.
"New password confirm": Re-enter the new password.
Once you have entered the required information, click on Modify so that the streamer adopts the new access
password. If, at the last moment, you decide to keep the previous password, click on Cancel.
If you do not know the old password, i.e. the password used to access the current configuration
session, you must perform a Password Reset as explained in the Installation and Access manual.
Following this reset, the program password will be the default password: admin.
IMPORTANT: When you perform a password reset, the IP address assigned to the streamer on the
Network card (previous page) automatically changes to the default setting: http:// 92.168.1.4.
Note
!
Shutdown
If you need to reboot the streamer for any reason, click on the Shutdown tab. The
following card is displayed:
Figure 1.5 - Shutdown card of the Configuration window.
Click on Reboot. A reset is then performed after which the Output Streams screen
will appear, this is the presentation screen of the program.
Configuration

10
Configuration
Update Firmware
If you wish to update the streamer's firmware, click on the Update Firmware tab. The
card displayed (Figure 1.6) shows the firmware version that the streamer has at the
present time.
(The firmware is software stored in the module which is responsible for its basic operation).
Figure 1.6 - Update Firmware card of the Configuration window.
WARNING: The firmware update file will have been previously stored on the PC hard drive. (You can
download it from http://www.ikusi.com).
Click on Browse... and select the firmware update file from the hard drive. When the file
name is in the box, click on Start. The new firmware will be installed on the streamer
and then its name will appear in the card replacing the one of the file before.