IDW G-80L Manual de usuario

G-Series Cooler
Instruction Manual
G-80L
ELECTRIC IMPULSE COOLER

Innovative DisplayWorks
G-80L
FOR YOUR FUTURE REFERENCE
• This easy-to-use manual will guide you in getting the best use of your cooler.
• Remember to record the model number and the serial number. This information can be found on the
inside of your cooler.
• Keep your receipt with this manual for future warranty service.
Model #:
Serial #:
Date of Purchase:
TABLE OF CONTENTS
Parts and Identication ......................................... 2
Safety Instructions................................................. 3
Preparation........................................................... 4
Location................................................................ 5
Installation and Operation..................................... 5
Beverage Storage.................................................. 5
Maintenance......................................................... 6
Changing Graphics................................................ 7
How to Replace Lid................................................ 7
Cleaning ............................................................... 8
Troubleshooting .................................................... 8
Circuit Diagram................................................... 10
1
G-80L
Instruction Manual

Instruction Manual
Innovative DisplayWorks
G-80L
2 3
PARTS AND IDENTIFICATION
1. Door
2. Top Frame
3. Cabinet
1
2
3
4
5
4. Bottom Frame
5. Caster
SAFETY INSTRUCTIONS
When using this appliance, always follow the basic safety precautions:
1. Read the entire User’s Manual before operating this appliance.
2. Use this appliance only for its intended purpose as described in this User’s Manual.
3. This cooler must be properly installed in accordance with the installation instructions before being used. See grounding
instructions.
4. IDW requires that a dedicated circuit be used for the unit. Failure to do so voids warranty.
5. Never unplug your cooler by pulling on the power cord. Always grasp the plug rmly and pull it straight out from the
outlet.
6. Unplug your cooler before cleaning or making any repairs.
Note: If for any reason this product requires service, we strongly recommend that a certi ed technician perform the service.
7. When disconnecting the power source, wait at least 5 minutes to reconnect the power to avoid damage to the compressor
and the cooling system.
8. Immediately repair or replace all electrical cords that have become frayed or otherwise damaged. Do not use a cord that
shows cracks or abrasion damage along its length, the plug or the connector end.
9. Do not operate or store your cooler near or around explosive fumes, gasoline or other ammable vapors and liquids.
10. Do not use ammable liquids to clean unit.
11. Setting the temperature control to the 0 position does not remove power to the light circuit, perimeter heaters, or
evaporator fans.
12. Do not adjust the temperature control. The temperature control is factory set between levels 4 and 5 for maximum
performance.
13. To avoid damage to the casters, do not transport the cooler on rough surfaces.
IMPORTANT!
Please Save These Instructions
For Proper Disposal of the Refrigerator!
PRE-CAUTION, NON-OPERATING COOLERS SHOULD HAVE:
1. Door removed
2. Baskets kept in place in order to prevent any small child from climbing inside cooler
FOR PROPER DISPOSAL OF COOLER: Distributors / retailers need to contact a quali ed service technician:
1. To recover all refrigerant from the cooler
2. To remove the compressor or remove the oil from the compressor
Then the distributor / retailer can contact their local metal recycling center to pick up the remaining cabinet, baskets, etc.
By law, disposal of hazardous wastes may be subject to nes and imprisonment under the provisions of the environmental
regulations. For more information please visit: http://www.epa.gov/osw/hazard/index.htm

Instruction Manual
Innovative DisplayWorks
G-80L
54
LEVELING/LOCATION
•Place unit in a well-ventilated area.
WARNING: Warranty is void if ventilation is insufcient.
•Unit must be leveled for proper operation, this will help prevent condensation.
• The cooler should be leveled front to back and side to side with a leveler.
INSTALLATION AND OPERATION
1Connect the Power Source. After 30 minutes of operation, the unit should show signs of cooling.
2After the empty cooler has been operating for a period of 5 hours, the unit can be loaded with products.
BEVERAGE STORAGE
1Do not overload the cooler beyond the red limitation line.
2Leave adequate space between beverage cans to allow air circulation.
3This cooler is primarily for storing beverage cans and plastic bottles. Avoid putting
glass containers in the cooler.
4All beverage products should be properly sealed to avoid leaking into the cooler.
INSTALLATION
Installation of the cooler must be done according to applicable local codes or equivalent.
Ambient Environment
• Place cooler on an even surface to reduce vibration and noise.
• To transport, do not tilt the cooler beyond a 45 degree angle.
• Do not place cooler in direct sunlight or near any heat sources.
• Do not place cooler in environment temperatures that exceed 109°F.
• Do not place cooler in below normal temperatures.
• Do not place cooler in extreme humid environments, this may cause components to rust.
• Do not place cooler near constant running or splattering water, this may cause immediate damage to refrigeration system.
• Must allow at least 4” between rear of cooler and wall for proper ventilation and heat dissipation of cooler.
• Do not place furniture or other articles with sharp edges near the cooler in order to prevent damage to the glass door.
• This cooler is for indoor use.
• Place unit in it’s nal location, making certain there is adequate ventilation in the room.
WARNING: Warranty is void if ventilation is insuf cient.
PREPARATION PRIOR TO OPERATION
Unpacking
• Remove all packaging materials before using cooler. This includes: foam pedestal, adhesive tape (used to x accessories)
and protective gaskets.
• Inspect cooler for concealed damage. Immediately le a claim with the freight carrier if there is damage. IDW is not
responsible for damage incurred during shipping.
• Cooler must remain unplugged in an upright position for 1 hour prior to use.
• Clean the interior surface with a soft cloth and lukewarm water before operation.
• Ensure that drain hose or hoses are positioned in the pan.
• Remove plug and cord from inside the lower rear of the cooler.
• The unit should be placed close enough to the electrical supply so that extension cords are not used.
Electrical Requirements
• This model operates with a 110V/60Hz power supply. Check the electrical outlet for proper voltage.
• Dedicate one outlet for the use of the cooler.
• Do not use an extension cord or any other multiple connectors as this can lead to compressor failure.
• If the cord is damaged, it must be replaced.
• For your safety, plug the unit into a grounded wall outlet. Please check with a certi ed electrician for details.
WARNING: Do not use extension cords.
WARNING: Compressor warranties are void if compressor burns out due to low voltage.
WARNING: Power cord ground pin must NOT be removed!

Instruction Manual
Innovative DisplayWorks
G-80L
6
Changing Electric Impulse Cooler Graphics:
CHANGING GRAPHICS
7
MAINTENANCE
Accessing Cooler Components:
2 Remove the bafer from cooler.
3Using a Phillips screwdriver,
unscrew the (4) screws at the base
of the cooler.
1Remove the basket from the inside of the cooler.
5Lay the body of the cooler on its side to access
components.
6To re-assemble the cooler align the
notch at base of the body with the
cooler cord. Then reverse steps 1-5.
4The body of the cooler can now be worked free from the frame.
2Wedge the graphic under the plastic frame of the cooler.
3Remove the covering on the double-
stick tape to adhere the graphic in
place.
1Place graphic around barrel, making sure to align the grill holes in the graphic with the grill
holes on the cooler to allow proper ventilation for the cooler.
HOW TO REPLACE LID
2 Remove the (2) hinge boxes in the direction of the arrows
shown on image.
3Disconnect the door LED strand,
replace the lid.
1 Unscrew (4) screws using a Phillip’s screwdriver.
4Replace the lid following the
above directions in reverse order.

Instruction Manual
Innovative DisplayWorks
G-80L
8 9
CLEANING
•Unplug the cooler prior to cleaning.
•Unplug the cooler at the electrical outlet; never pull the service cord.
•Do not use sharp or pointed objects for cleaning.
•Do not spray water directly onto cooler, and do not use hard or steel brushes to clean the cooler.
•Clean the inside cabinet of the cooler with a clean, damp cloth or with mild soap.
•Avoid damaging the cooler by using only non-abrasive cleaning products. Do not use organic solvents, boiling water,
washing powder or acid while cleaning.
If the cooler is unused for a long period of time, unplug the electrical cord, follow cleaning instructions, and open or remove
the lid.
MOVING THE COOLER
•Remove all product from the unit.
•Secure all loose parts inside the cooler.
•Tape the door shut.
•Ship the cooler in an upright position.
TROUBLESHOOTING
If your cooler is not working properly:
•Check the electrical outlet for power, and check that the plug is properly inserted into the outlet.
•Check the circuit breaker for a tripped or blown fuse.
•Be sure that the condenser is free of dirt and dust.
If your cooler is making noise:
• Check that the cooler is level and on a at surface.
If the compressor frequently turns on and off, check for the following:
•The room temperature may be higher than usual.
•The cooler door is completely closed.
•The door gasket is sealed correctly.
• Sufcient clearance around the cooler for airow.
•Proper temperature settings.
•The cycling frequency will reduce when all of the cans reach the set temperature.
The following is not a malfunction:
• Murmur noises caused by the ow of refrigerant when each cooling cycle ends.
•Ice formed on the side of the cooler is caused by moisture from the surrounding environment and the normal opening
and closing of the lid.
•Water drops on the door lid occur when the ambient humidity is high.
REFRIGERATION
•The G-80L Electric Impulse Cooler utilizes R134a refrigerant.
SPECIFICATIONS
Model: G-80L Electric Impulse Cooler
Power Supply (V/Hz): 110-115/60HZ
Dimension (Diameter x H): 18” x 40-1/4”
Box Dimension (Diameter x H): 18-1/2” x 44-3/4”
G-80L CIRCUIT DIAGRAM
M2
F
M1
AD2
SAT
RT
XP
M
M
-M
~
~
M
N
L
GND
AD1
XP-Power plug M-Compressor
AD1-LED light adaptor
RT-Starting relay SAT-Thermostat
F-Overload protector M2-Condenser fan
LED
light
MI-Inner fan
AD2- Inner fan adaptor
M2
F
M1
AD2
SAT
RT
XP
M
M
-M
~
~
M
N
L
GND
AD1
XP-Power plug M-Compressor
AD1-LED light adaptor
RT-Starting relay SAT-Thermostat
F-Overload protector M2-Condenser fan
LED
light
MI-Inner fan
AD2- Inner fan adaptor
M2
F
M1
AD2
SAT
RT
XP
M
M
-M
~
~
M
N
L
GND
AD1
XP-Power plug M-Compressor
AD1-LED light adaptor
RT-Starting relay SAT-Thermostat
F-Overload protector M2-Condenser fan
LED
light
MI-Inner fan
AD2- Inner fan adaptor

Innovative DisplayWorks, Inc.
To locate the distributor in your area go to: http://www.idw.global/contact/#distributors
G-Series Cooler
Instruction Manual
Tabla de contenidos
Otros manuales de Accesorios de IDW

IDW
IDW G-Series Manual de usuario

IDW
IDW GS-1 Manual de usuario

IDW
IDW GS-2.5-N23EB Manual de usuario

IDW
IDW G-Series Manual de usuario

IDW
IDW G-Series Manual de usuario

IDW
IDW G-Series Manual de usuario

IDW
IDW G-Series Manual de usuario

IDW
IDW G-Series Manual de usuario

IDW
IDW G-Series Manual de usuario

IDW
IDW G-Series Manual de usuario