iCleanse Swift units provide a chemical-free, general-purpose disinfection for
mobile phones and tablets, as well as stethoscopes, hair styling tools, CB radios,
and so much more.
Swift units have been designed for minimal contact with what you place
in it, allowing maximum surface coverage by germicidal light during the
disinfection cycle.
Please read through this guide thoroughly to ensure proper use of your Swift unit.
Meet your Swift
About your iCleanse Swift Unit
2

iCleanse Swift units include an intuitive touch-screen interface that visibly shows
the status of the device and if there are any errors. The screen will turn off after
one minute of idle use. To wake the unit back up, touch anywhere on the screen
or open the drawer.
Initializing: The lamps are warming up to start disinfection cycle.
Disinfecting: The unit is in the middle of a disinfection cycle.
Drawer Open: The drawer is not fully shut. To continue with cycle, please ensure
the drawer is fully shut.
Disinfection Complete: The disinfection cycle is complete and you can now open
the drawer and remove your device.
Disinfection Not Complete: The disinfection cycle was interrupted, by opening
the drawer. Close the drawer and restart the cycle.
Replace Lamps: The lamps have met their 4,000 cycle lifespan and must be
replaced in order to disinfect.
Lamp Fault: This could mean that the lamps are not accurately in place. Double
check that the lamps are installed correctly.
Indicators
About your iCleanse Swift Unit
3

Tech Specs
About your iCleanse Swift Unit
4
Model Swift
Dimensions 20 in x 17.5 in x 8.75 in / 50.8 cm x 44.5 cm x 22 cm
Weight 35.5 lbs / 16.1 kg
Basket Accommodations 11 in x 13 in x 2.75 in / 28 cm x 33 cm x 7 cm
Disinfection Cycle Time User Defined – Default is 30 seconds
Operating Temp. Range 37°F - 95°F / 2.78°C - 35°C
Operating Humidity Range 5-95% @ 82.4°F / 5-95% @ 28°C
Storage Humidity Range 0-95% Non-condensing
AC Supply Voltage 120VAC - 240VAC
Installation Requirements Level Surface; 3 in / 7.5 cm from obstruction
Power Cord Length 6.5 ft / 2 m

5
About your iCleanse Swift Unit
Swift XL Swift Mini
26 in x 17.5 in x 8.75 in / 66 cm x 44.5 cm x 22 cm 15.5 in x 17.5 in x 11 in / 39.4 cm x 44.5 cm x 28 cm
38 lbs / 17.2 kg 29 lbs / 13.2 kg
11 in x 18 in x 2.75 in / 28 cm x 46 cm x 7 cm 8.5 in x 11 in x 4.5 in / 22 cm x 28 cm x 11 cm
User Defined – Default is 30 seconds User Defined – Default is 30 seconds
37°F - 95°F / 2.78°C - 35°C 37°F - 95°F / 2.78°C - 35°C
5-95% @ 82.4°F / 5-95% @ 28°C 5-95% @ 82.4°F / 5-95% @ 28°C
0-95% Non-condensing 0-95% Non-condensing
120VAC - 240VAC 120VAC - 240VAC
Level Surface; 3 in / 7.5 cm from obstruction Level Surface; 3 in / 7.5 cm from obstruction
6.5 ft / 2 m 6.5 ft / 2 m

Ensure the Swift unit is on a level surface and has 3 to 4 inches of open space
behind to allow for proper airflow for the cooling fan.
Remove the protective cover from the touchscreen.
Plug in the power cord to any standard outlet and power on the unit by using the
switch in the back.
The touchscreen display will light up and prompt you to input today’s date. Input
today’s date (mmddyyyy) and press confirm. This is the in service date.
On the bottom right of the main screen (Figure 01., page 7) is a countdown ticker
for the remaining cycles. Lamps have a usable life of 4,000 cycles. At 500 cycles
remaining, there will be a icon as a reminder that new lamps will be needed.
The default disinfection time set at the factory is 30 seconds. If you would like to
increase the disinfection time, please see page 10.
Setting up your Swift Unit
Getting Started
6

Getting Started
7
Figure 01. Main Screen
Start Button
Starts disinfection cycle
Countdown Ticker
Displays remaining cycles
Settings Icon
Access to the settings menu
Swift
START
4,000 CYCLES
REMAINING

To access the settings menu (Figure 02) make sure your unit is not in a
disinfection cycle and is displaying the main screen. In the bottom left corner is a
gear icon. Tap this icon and input the default pass code (1234) and tap enter.
From the settings menu, you can replace lamps, set the disinfection time, view
unit information, access customer support, and change the default pass code.
Selecting Unit Information will tell you about your device.
Manufactured Date: Is the date your unit was assembled.
In Service Date: Is the date you set your unit up.
Last Lamp Replacement: Will tell you the date you last replaced your lamps.
Serial Number: Note this on page 16 for future reference.
Software Version: Is the version of software currently running on your device.
If you wish to change the pass code on the unit, tap Change Pass code. Input
your new 4-digit pass code and tap Enter. You will be prompted to enter the
pass code again, hit Enter to confirm. Your pass code is now changed.
Accessing the Settings Menu
Getting Started
8

Getting Started
9
Figure 02. Settings Menu
SETTINGS
HOME
Unit Information
Customer Support
Change Passcode
Lamp Replacement
Disinfection Time
Otros manuales para Swift