Hydro systems EvoRinse Manual de usuario

Installation and Operation Manual
HYD90098598 Rev A
EvoRinse

2
Contents
1 Specification
Description
Product Features
Specification
Intended Use
Product Diagram
Kit Contents
2 Installation
Site Survey & Installation Requirements
Installation Diagram
Mechanical Installation
Wall mounting
Rinse discharge hose connection
Rinse aid tube connection (product option)
Water connection
Electrical Installation
Electrical connections
Mains power wiring
3 Troubleshooting
Dead Unit
4 Maintenance
Maintenance
Every Maintenance Visit
Spray Nozzle Replacement
5 Spare Parts
6 Decommissioning & Disposal
7 Safety
8 EC Declaration of Conformity
9 WEEE

3
1.3 Specification
Product Dimensions (unboxed)
Size 254mm (W) x 366mm (L) x 234mm (D)
Weight 2.3 Kg
Product Dimensions (boxed)
Size 370mm (W) x 425mm (L) x 305mm (D)
Weight 3.4 Kg
Electrical
Input voltage / Frequency / Current 100 to 240 VAC / 50/60 Hz. / 1.5 A (Max.)
Power 12W (Max)
Electrical Class Class II
1. Specifications
Installation Environment
Temperature 10°C to 50°C (max.)
Humidity 95% relative humidity (max.)
Indoor Installation Indoor use only. Must not be installed outdoors
Performance
Detergent dissolution rate Min-max
Water Inlet Connection
Water temperature 5°C to 60°C (max.)
Pressure 0.2MPa (2 bar) - 0.6MPa (6 bar)
Inbuilt backflow prevention - EN1717 DB - Category 4 chemicals
1.2 Product Features
Bottle lockout feature to prevent non-approved chemicals
being used in the product.
1.1 Description
The EvoRinse is a rinse powder / solid rinse aid dissolver for
use with EvoWash warewash machines.
1.4 Intended Use
• The EvoRinse is intended for use in industrial applications
and is not suitable for domestic use.
• The product must only be used for rinsing in dish and
warewash applications. The manufacturer waives any
responsibility arisen from incorrect usage or transportation.

x 4 x 4 x 4
2
1
x 2
4
KEY:
1. Switch Lever
2. Keyway (optional)
3. Fixing Points (x4)
4. Water Inlet
5. Water Filter
6. Mesh Screen
7. Water Spray Nozzle
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
1
2
3
4
5
6
7
3
4
5
1.6 Kit Contents
1.5 Product Diagram
6
7

5
2. Installation
CAUTION Before an installation takes place it is
advisable to complete a site survey to ensure
the EvoRinse can be installed in a position that
meets all the requirements below.
CAUTION Do not install unit in an ATEX environment
WARNING Electrical installation should be completed
by a qualified electrician. All local and
national electrical regulations are to be
observed.
2.1 Site Survey & Installation Requirements
• Unit is to be installed by a trained technician; all local and
national water regulations are to be observed.
• Unit must be installed indoors, in an area that does not
suffer excess temperature changes, direct sunlight, frost or
precipitation of any kind.
• The area must be free of high levels of EMC disturbance.
• Ensue the unit is mounted in an accessible location, above
the height of the dishwasher detergent and rinse inlet
connections.
• Installer to ensure the suitability of the wall or mounting
substrate, which should be flat and perpendicular to the
floor.
• Unit location should be well lit for any maintenance, and
should be free of high levels of dust particulates.
• Scheduled maintenance should be carried out on the unit
at least once per year.
• It is a legal requirement that all water supply hose sets must
be compliant with IEC 61770.
• Ensure that the chemicals being used are compatible with
the tubing supplied. If you are unsure, please contact your
local distributor.

6
Installation Diagram
Rinse Feed Hose
Dish Washer

7
Wall Mounting
NOTE Ensure the wall anchors are suitable for the wall being mounted to.
1. Offer the product to the wall
in the chosen install location
and mark through the 4
mount points.
2. Drill 4 x holes in the marked
positions using a Ø8.0mm
drill bit.
3. Insert the 4 x wall anchors
into the drilled holes.
4. Secure the product onto the
wall using the 4 x screws and
washers, using a PZ2 driver.
2.3 Mechanical Installation
Figure 4: How to mount the unit to the wall
Push
Fitting
Using the clear, rinse tubing supplied with the EvoRinse, connect one
end (Inlet to Rinse Pump) to the reservoir outlet on the unit (into push
fitting).
Figure 5: Connecting detergent supply tubing

8
Figure 6: Rinse aid hose connection
Cable ties are provided in the fittings kit so that tubing can be tied
together / the wall to create a neat and safe installation.
Inlet Tubing.
1. Connect the tubing from the EvoRinse to the inlet on the rinse pump
(left hand fitting). Loosen the compression fitting by 1 turn, then
push the tube into the fitting and tighten.
Outlet Tubing
1. Install one end into the outlet of the rinse pump (right hand fitting).
Loosen the compression fitting by 1 turn, then push the tube into
the fitting and tighten.
Inlet
Outlet
Rinse Aid Tube Connection - EvoRinse Unit
NOTE Ensure there are no kinks or sharp bends in the tubing between the unit
and the rinse injection fitting, to ensure free flow of rinse chemical into
the water line.

9
2. Ensuring the tubing is the correct length, connect the other end of
the tubing to the rinse injection fitting into the dish machine. Loosen
the compression fitting by 1 turn, then push the tube into the fitting
and tighten.
Water Connection
CAUTION
Water supply temperature should be between 5-60°C.
Maximum static water pressure 0.6MPa (6 bar). Ensure a pressure
regulator is used before the water inlet if static water pressure will
fluctuate above this level.
CAUTION
An isolation valve should be fitted between the water supply and the unit
to ensure the water supply can be shut off if required.
• The water inlet connection type will vary between models. Current
connection types are:
o 15mm, 3/8”, ¼” push fit connections
o ¾” Female BSPP
• Connect the water supply to the water inlet, ensuring that the
supply hose is supported so as not to create unnecessary force on
the inlet.
2.4 Electrical Installation
WARNING
Electrical installation and maintenance should be completed by a
qualified electrician. All local and national electrical regulations are to
be observed.
CAUTION
All electrical connections (excluding the conductivity probe) are to be
made either in the dish machine control circuit panel or in a suitable,
external junction box.
All cable entries into new equipment must be made with a water tight
conduit fitting or gland, meeting the appropriate local and national
regulations.
Ensure all wiring is routed neatly and safely between appliances, as not
to create any trip hazards that could result in injury, or damage to the
equipment or wiring.

Brown - Live
200-249 VAC ~50/60 HZ
Blue - Neutral
Mains Power
10
Electrical Connections
Figure 7: Wiring Schematic from product
Mains Power Wiring
Brown (Live)
200-249 VAC ~50/60 HZ
Blue (Neutral)
230 VAC Mains Power
Live Neutral
Figure 8: Mains power wiring diagram
Brown - Live
200-249 VAC ~50/60 HZ
Blue - Neutral
Mains Power