Huawei SmartLogger2000 series Manual de usuario

HUAWEI TECHNOLOGIES CO., LTD.
SmartLogger2000
Quick Guide
Issue: 01
Part number: 31507740
Date: 2016-08-25

No.
Port (Silk
Screen
)
Function
Description
1
RF1, RF2
Reserved
Reserved.
2
12V
OUT
12 V DC output
Provides 12
V DC power supply with a maximum
current
of 100 mA.
3
12V
IN
12 V DC input
Connects
to the power adapter.
4
USB
USB port
Connects a USB flash drive.
1
1Overview
Port Description
1.2
1. The information in this document is subject to change without notice. Every effort has been
made in the preparation of this document to ensure accuracy of the contents. However, all
statements, information, and recommendations in this document do not constitute a warranty of
any kind, express or implied.
2. Before installing the device, carefully read the SmartLogger2000 User Manual to get familiar
with the product information and precautions. SmartLogger is short for SmartLogger2000 in the
following text.
3. Install and use the device according to this document and the user manual. Otherwise, the
device may be damaged. Use insulated tools when installing the device.
4. This section describes the installation and cable connection operations using the SmartLogger
applied in the non-SmartACU2000 smart array controller (smart array controller for short)
scenario as an example.
Copyright © Huawei Technologies Co., Ltd. 2016. All rights reserved.
Model
PLC Module
Configured?
Remarks
S
martLogger2000-10
Yes
The built
-in Bluetooth
module supports only
Android APP.
SmartLogger2000
-10-B
Yes
The built
-in Bluetooth
module supports both
Android APP and IOS APP.
S
martLogger2000-11-B
No
Model Description1.1
NOTICE

No.
Port (Silk
Screen
)
Function
Description
5
SFP1, SFP2
Ethernet optical
port
Connects
to an ATB or another cascaded
SmartLogger
.
6
ETH1, ETH2
Ethernet electrical
port
Connects to an Ethernet LAN switch, router, POE or
PC
device.
7
DO
Digital output (DO)
Relay output.
8
COM1
–COM6
RS485
communications
Six RS485 ports that can be connected to devices
such
as the inverter, box-type transformer, electricity
meter
, or EMI.
9
Default
Default key
Resets and restarts the Bluetooth module or resets
the
SmartLogger IP address to the default IP address
(
valid within 5 minutes).
10
AC1, AC2
AC power cable
ports
Connects to A, B, and C three
-
phase inputs, and used
for
power line communication (PLC) with the inverter.
11
External
grounding
N/A
12
AI1
–AI8
Analog input (AI)
•
SmartLogger2000-10: AI1–AI4: 4–20 mA and 0–
20
mA input current (passive); AI5–AI8: 4–20mA and
0–20 mA input current (active)
•
Other models: AI1: 0–10 V input voltage (passive);
AI2–AI4: 4–20 mA and 0–20 mA input current
(passive); AI5–AI8: 4–20 mA and 0–20 mA input
current (active)
13
AO1
–AO6
Analog output
(AO)
4
–20 mA, 0–20 mA current output.
14
DI1
–DI8
Digital input (DI)
Connects to a dry contact input
.
2Typical Cable Connection Scenarios
Smart Array Controller Scenario
2.1
2
1. The general input power cable for the smart array controller needs to be prepared by the
customer. Recommended cable: four-core armor cable with the operating voltage to the ground
greater than or equal to 600 V and the cross-sectional area of a single core being 4 mm2
2. The cable from the busbar to the knife switch needs to be prepared by the customer.
Recommended cable: three-core armor cable with the operating voltage to the ground greater
than or equal to 600 V and the cross-sectional area of a single core being 4 mm2.
3. The SmartLogger and the three RS485 signal surge protective devices (SPDs) used by the
SmartLogger have been installed before delivery.
4. The SmartLogger PGND cable, AC power cable, power adapter and its power cable, and the
communications cable between the SmartLogger and the RS485 signal SPD have been
installed before delivery.
5. The PID module and inductor are configured only in the smart array controller (with a PID
module) and have been installed before delivery.
NOTICE

3
RS485/PLC+Optical Fiber
Component
Recommended Model or
Specifications
Component Source
Quantity
P
ID module
P
ID01
Factory
-installed
1 PCS
PID inductor (working with
the PID module)
EIFI50ohm
Factory
-installed
1 PCS
SmartLogger
SmartLogger2000
Factory
-installed
1 PCS
RS485 signal SPD
SPM01A
Factory
-installed
3 PCS
ATB
CT
-GZF2PJ-8 or CT-GPH-A-8
Purchased
from
Huawei
1 PCS
Knife switch
Fuse
Rated voltage ≥
500 V; rated
current: 6 A
Prepared by
customer
3 PCS
Knife switch
box
Rated voltage ≥
500 V; rated
current ≥ 6 A;
poles: 3P
Prepared by
customer
1 PCS

4
RS485/PLC+LTE
Component
Recommended Model or
Specifications
Component Source
Quantity
P
ID module
P
ID01
Factory
-installed
1 PCS
PID inductor (working with
the PID module)
EIFI50ohm
Factory
-installed
1 PCS
SmartLogger
SmartLogger2000
Factory
-installed
1 PCS
RS485 signal SPD
SPM01A
Factory
-installed
3 PCS
POE module
POE35
-54A or POE85-56A
Purchased from Huawei
1 PCS
POE SPD
POE
-2A
Purchased from Huawei
1PCS
CPE
EG860V2
-C71
Purchased from Huawei
1 PCS

5
Non-Smart Array Controller Scenario
2.2
1. If the SmartLogger communicates with an inverter over an AC power cable, an MCB and a knife
switch need to be installed to prevent device damage in the case of short circuits.
2. If the SmartLogger communicates with an inverter over an AC power cable, the cable from the
knife switch to the MCB and the cable from the busbar to the knife switch both need to be
prepared by the customer. Recommended cable: three-core armor cable with the operating
voltage to the ground greater than or equal to 600 V and the cross-sectional area of a single
core wire being 4 mm2.
3. The power cable delivered with the SmartLogger is 1 meter long, the power adapter cable is 1.5
meters long, the network cable is 2.2 meters long, and the AC power cable is 1.5 meters long.
Reserve the installation positions for components based on the cable lengths.
Component
Recommended Model or
Specifications
Component Source
Quantity
Knife
switch
Fuse
Rated voltage ≥
500 V; rated
current: 6 A
Prepared by customer
3 PCS
Knife
switch
box
Rated voltage ≥
500 V; rated current ≥ 6
A;
poles: 3P
Prepared by customer
1 PCS
Component
Recommended Model or
Specifications
Component Source
Quantity
SmartLogger
SmartLogger2000
Purchased from Huawei
1 PCS
RS485 signal
SPD
X4B
-05
Purchased from Huawei
3 PCS
RS485/PLC+Optical Fiber
NOTICE

Component
Recommended Model or Specifications
Component
Source
Quantity
ATB
CT
-GZF2PJ-8 or CT-GPH-A-8
Purchased
from Huawei
1 PCS
Knife
switch
Fuse
Rated voltage ≥
500 V; rated current: 6 A
Prepared by
the customer
3 PCS
Knife switch
box
Rated voltage ≥
500 V; rated current ≥ 6 A;
poles: 3P
Prepared by
the customer
1 PCS
MCB
Rated voltage ≥
500 V; rated current ≥ 6 A
Prepared by
the customer
1 PCS
Socket
Connects to the power
adapter
Prepared by
the customer
1 PCS
6
Component
Recommended Model or Specifications
Component
Source
Quantity
SmartLogger
SmartLogger2000
Purchased
from Huawei
1 PCS
POE module
POE35
-54A or POE85-56A
Purchased
from Huawei
1 PCS
POE SPD
POE
-2A
Purchased
from Huawei
1 PCS
RS485 signal SPD
X4B
-05
Purchased
from Huawei
3 PCS
RS485/PLC+LTE

Installation Space (Unit: mm)
3.1
3Installing the SmartLogger
7
Chassis dimensions (including mounting ears)
Installation clearances
Installation clearances
Component
Recommended Model or Specifications
Component
Source
Quantity
CPE
EG860V2
-C71
Purchased
from Huawei
1 PCS
Knife
switch
Fuse
Rated voltage ≥
500 V; rated current: 6 A
Prepared by
the customer
3 PCS
Knife
switch
box
Rated voltage ≥
500 V; rated current ≥ 6 A; poles:
3P
Prepared by
the customer
1 PCS
MCB
Rated voltage ≥
500 V; rated current ≥ 6 A
Prepared by
the customer
1 PCS
Socket
Connects to the power
adapter
Prepared by
the customer
1 PCS
Installation Mode3.2Wall-mounting
Install the SmartLogger on a wall that is flat and has the bearing capacity to securely hold the
SmartLogger which weighs 3800 g.
Wall-mounting
Guide rail-mounting
Chassis dimensions
(including the guide rail mounting brackets)
NOTICE

1. Determine mounting holes based on the hole positions in the mounting ears, and mark
the mounting holes using a marker.
If you need to use a ladder to install the device on a high position, take measures to protect
yourself from falling down.
2. Drill holes by using a hammer drill and install expansion sleeves, washers, and tapping screws.
Unit: mm
8
Screw assembly for wall-mounting:
(1) ST3.5 tapping screw
(2) Washer
(3) Expansion sleeve
3. Put the tapping screws through the SmartLogger mounting ears and washers into the mounting
holes in the wall.
NOTICE
Unit: mm

Guide rail-mounting
Huawei does not provide the SmartLogger guide rail. If the customer chooses this installation mode,
the customer must prepare a 35 mm standard guide rail.
Unit: mm
1. Remove the mounting ears from the
SmartLogger using a Phillips screwdriver. 2. Secure the guide rail clamps using M4x8
screws removed from the mounting ears, and
tighten the screws to a torque of 1.2 N·m.
1. Secure the guide rail before mounting the
SmartLogger.
2. Verify that the length of the guide rail is
sufficient for securing the SmartLogger.
The recommended length is 450 mm or
greater.
9
4. Tighten the tapping screws to a torque of 0.3 N·m using a torque screwdriver.
NOTE
Otros manuales para SmartLogger2000 series
4
Tabla de contenidos
Otros manuales de Panel solar de Huawei