HPI Racing AZURE Manual de usuario

Installation and User Manual
CEILING FAN MUST BE INSTALLED
BY A LICENSED ELECTRICIAN
(NO OTHER PERSONS SHOULD ATTEMPT TO INSTALL THIS FAN)
*After installation, electricians must tick off all items on the
quick checklist and fill out their details towards the back of this
Installation Manual
ELECTRICIANS - TO PROTECT YOUR CUSTOMER’S WARRANTY, PLEASE READ
PAGE 2 OF THIS BOOKLET PRIOR TO THE INSTALLATION OF THIS PRODUCT.
The fan should only be installed and used indoors. Not
suitable for outdoor use and not recommended for
coastal locations.
Warranty Procedure*
For online warranty bookings visit: www.hunterpacific.com.au (24hours, 7 days)
For technical advice call: 1300 360 280 (Monday to Friday from 9am to 5pm EST)
* Warranty only available within Australia
AZURE
By HPI
™
Isolation switch and wall plate required. To suit the location and décor
these parts must be supplied by the installing electrician.

2
IMPORTANT INFORMATION
ELECTRICIANS MUST READ PRIOR TO INSTALLATION
1. Distributor and installer details and purchase receipts are essential for on-site warranty claims
and must be presented to repair personnel. A page towards the back of this manual has been
allocated to allow you to record these details.
2. Fans and fixed wiring products must only be installed by persons who are appropriately licensed
by the applicable State regulatory body. Therefore, to protect our repair personnel, on-site
warranty claims will not be accepted if products have been installed by unlicensed persons.
3. Damage caused by incorrect installation, force-majeure, electrical surges, lightning, power grid
fluctuations, water or by connection to alternative power supply sources (such as solar inverters,
etc.) is not eligible for warranty repair.
4. Blades must be replaced only as a complete set. Blades are supplied only as a pre-balanced set
and the replacement of individual blades may void the warranty by causing mechanical damage
to the motor, excessive noise or premature wear.
5. When products are installed in a location requiring special access equipment (such as
scaffolding or scissor lifts, etc) the cost of providing, installing and operating special access
equipment must be borne by the site owner.
6. “This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been giv-
en supervision or instruction concerning use of the appliance by a person responsible for their
safety. Children should be supervised to ensure that they do not play with the appliance.” (AS/
NZS 60335.1 C1.7.12)
DANGER: Contact with ceiling fan blades can cause serious injury or death.
To electricians and installers. The Australian Competition and Consumer Law 2010 mandates
consumer protection against defects or poor workmanship in provision of services (such as
installing a ceiling fan). To protect yourself and the consumer these instructions must be
followed. Failure to do so may result in the consumer making a claim against you for
consequential loss or damage.
7. A double pole isolation switch providing full disconnection of both fan and light must be fitted in
accordance with the wiring rules (AS/NZS 60335.1 C1.7.12.2).
For safety, and to protect your customers warranty, the following must be taken into
account when installing and operating the product(s):
IF THERE ARE ANY PROBLEMS WITH THE PRODUCT AT TIME OF
INSTALLATION THE INSTALLER MUST CONTACT THE WARRANTY
HOT LINE NUMBER 1300 360 280 BEFORE LEAVING THE JOB
SITE. PLEASE DO NOT REMOVE THE FAN FROM THE CEILING
ONCE INSTALLED UNLESS INSTRUCTED TO DO SO.
(a) DO NOT USE SOLID-STATE WALL CONTROLLERS. Neither leading nor lagging edge
controllers will give satisfactory performance. Wall controls must only be types approved
for use by HPI.
(b) The fan, light and bracket must be earthed.
(c) Fan and light must be run from the same final circuit.
(d) Mounting bracket must be firmly screwed to a solid structure such as a concrete ceiling,
steel structure or timber framing. If additional bracing is added it must be firmly secured to
the rafters and not left floating on the ceiling. Special mounts, such as T-hooks, are
available for certain types of installation. DO NOT USE COUNTERSUNK SCREWS.
(e) After installation, fan blades must be at least 2.1 m (7 feet) above floor level.
(f) The use of these products by children and the infirm must be under supervision.

3
Installation &
User Manual
CODE SIZE FAN MODEL NAME COLOUR
A2322 122cm (48”) Azure without light Matt Black motor &
Matt Black Blades
A2323 122cm (48”) Azure without light White Motor & White
Blades
A2324 122cm (48”) Azure without light Brushed Nickel Motor &
Brushed Silver Blades
A2325 122cm (48”) Azure with light
(E27 Lamp Holders)*
White Motor & White
Blades
A2326 122cm (48”) Azure with light
(E27 Lamp Holders)*
Brushed Nickel Motor &
Brushed Silver Blades
A2327 122cm (48”) Azure with light
(18W CCT LED Light)
White Motor & White
Blades
A2328 122cm (48”) Azure with light
(18W CCT LED Light)
Brushed Nickel Motor &
Brushed Silver Blades
A2329 122cm (48”) Azure with light
(18W CCT LED Light)
Matt Black Motor &
Matt Black Blades
IMPORTANT INFORMATION
The table below contains information that can help you quickly identify the product you are
installing. If you have any difficulties installing our product we recommend you to call our
technical advice line on 1300 360 280.
AZURE
By HPI
* Lamps for E27 Lamp Holders not supplied.
* Do not exceed maximum rated lamp capacities:
E27: 40W incandescent or 20W CFL/or LED (each lamp holder)
™

4
Hanger Bracket
Parts List - Azure no light
Base Plate
Azure
fan
Installation &
User Manual
Part Qty Part Qty
Hanger Bracket 1Spring washer 2
Bracket Mounting Screw 2Flat washer 2
Azure fan body (Pre-
assembled Fan motor,
down rod, and canopy )
1
3 speed Wall Control kit
(includes wall mech & ca-
pacitor)
1
Blades 4Base Plate 1
Blade screw washer 12
Blade screws 12
Screws 2
AZURE
By HPI
Blade
Unpack ceiling fan carefully. Place fan motor on a cloth or soft surface to avoid damaging the finish.
Do not lay motor housing on its side as the decorative housing may become bent or damaged.
™
Wall
Controller
Flat
Washer
Spring
Washer
Bracket
Screw
Screws
Blade
Screw
Blade Screw
Washer

5
Parts List - Azure with E27 Lamp Holders
Installation &
User Manual
AZURE
By HPI
Hanger
Bracket
Glass
Diffuser
Azure
fan body
Part Qty Part Qty
Hanger Bracket 1Spring washer 2
Bracket Mounting Screw 2Flat washer 2
Azure fan body (Pre-
assembled Fan motor,
down rod, and canopy )
1
3 speed Wall Control kit
(includes wall mech & ca-
pacitor)
1
Blades 4Glass Diffuser 1
Blade screw washer 12 Twin E27 Lamp Holders
(Bulbs not supplied) 1
Blade screws 12
Screws 2
Blade
E27 Lamp
Holders
Unpack ceiling fan carefully. Place fan motor on a cloth or soft surface to avoid damaging the finish.
Do not lay motor housing on its side as the decorative housing may become bent or damaged.
™
Flat
Washer
Spring
Washer
Bracket
Screw
Screws
Blade
Screw
Blade Screw
Washer
Wall
Controller

6
Parts List - Azure with 18W CCT LED Light
Installation &
User Manual
AZURE
By HPI
Hanger
Bracket
Glass
Diffuser
Part Qty Part Qty
Hanger Bracket 1Spring washer 2
Bracket Mounting Screw 2Flat washer 2
Azure fan body (Pre-
assembled Fan motor,
down rod, and canopy )
1
3 speed Wall Control kit
(includes wall mech & ca-
pacitor)
1
Blades 4Glass Diffuser 1
Blade screw washer 12 18W CCT LED Light 1
Blade screws 12
Screws 2
Blade
Unpack ceiling fan carefully. Place fan motor on a cloth or soft surface to avoid damaging the finish.
Do not lay motor housing on its side as the decorative housing may become bent or damaged.
™
18W LED
Light
Azure
fan body
Flat
Washer
Spring
Washer
Bracket
Screw
Screws
Blade
Screw
Blade Screw
Washer
Wall
Controller

7
Installation Instructions
(Assembling the fan)
Installation &
User Manual
Fig. 1
Ø25mm
Ø1-1/8”
Fig. 2 Do not remove rubber pads on
bracket.
Fig. 3
Timber
Nogging
Hanger
Bracket
Fig. 4
AZURE
By HPI
1
2
3
4
™

8
1
2
3
Wiring Instructions (with and without light)
WARNING: To comply with AS/NZS 60335.1 an Isolation switch must
be fitted in series with the supply of this product.
Fig. 6
Wire colours indicative only.
Alternate colours marked with
their function.
Installation Instructions
(Assembling the fan)
Installation &
User Manual
1. Do not attempt to operate the fan (or light kit) with any wall control that is not approved by HPI for
use with its fans. DO NOT use solid state controllers. The use of unapproved controllers may void your
warranty.
2. Do not mix blade sets from one fan to another as this may upset the balance of the fan. If only one
blade is damaged you are still required to replace with a new set.
AZURE
By HPI
Fig. 5
™

9
Reverse
Switch
shown in
Forward
(Summer)
mode
Fig. 9
Installation &
User Manual
Installation Instructions
(Assembling the fan)
Direction fan will spin in REVERSE (Winter)
mode when viewed from underneath
Direction fan will spin in FWD (Summer)
mode when viewed from underneath
Reverse
Switch
shown in
Reverse
(Winter)
mode
AZURE
By HPI
Fig. 7
1
Fig. 8
1
1. Do not attempt to operate the fan (or light kit) with any wall control that is not approved by HPI for
use with its fans. DO NOT use solid state controllers. The use of unapproved controllers may void your
warranty.
2. Do not mix blade sets from one fan to another as this may upset the balance of the fan. If only one
blade is damaged you are still required to replace with a new set.
™

10
Installation &
User Manual
Azure — E27 light kit
This product uses real glass which can have sharp edges. Wear
gloves and eye protection when replacing lamps or glass.
Fig. 1
1
AZURE
By HPI
Fig. 2
Do not exceed maximum rated lamp capacities:
E27: 40W incandescent or 20W CFL/or LED (each lamp holder)
Lamps for E27 Lamp Holders not supplied.
1. Do not attempt to operate the fan (or light kit) with any wall control that is not approved by HPI for
use with its fans. DO NOT use solid state controllers. The use of unapproved controllers may void your
warranty.
2. Do not mix blade sets from one fan to another as this may upset the balance of the fan. If only one
blade is damaged you are still required to replace with a new set.
™
Tabla de contenidos