Hive Storion-SMILE-B3 Manual de usuario

OWNERS MANUAL
Primary Unit (Storion-SMILE-B3)
Secondary Unit (M4856-P)
www.hivesolar.com.au

Australia
Alpha ESS Australia Pty. Ltd.
Tel: +61 1300 968 933
E-mail: [email protected]
Website: www.alpha-ess.com.au
Add: Suite 1, Level 1, 530 Botany Road, Alexandria, NSW
China
Alpha ESS Co., Ltd.
Tel: +86 (0) 513 806 868 91
E-mail: [email protected]
Website: www.alpha-ess.com
Add: Jiu Hua Road 888, High-Tech Industrial Development Zone, Nantong City,
226300, Jiangsu Province
1.1 Copyright Declaration
The copyright of this manual is owned by HIVE Solar Batteries and all rights
are reserved.
• Please keep the manual within the vicinity of the HIVE Solar Battery.
• Please operate the HIVE Solar Battery strictly according to the safety and
operation instructions described in this manual.
• Do not operate the system before reading this manual.
1.2 Version Information
Version Date Contents
VO1 21.01.2020 HIVE Solar Batteries - Owner’s Manual (Rev 1)

OWNERS MANUAL
Take the sting out of your energy bills
Installation & Commissioning Checklist (for installers only)
Induction requirements (for installers only)
Important Safety Precautions
HIVE Solar Batteries
Technical Specications
Operating Principal
System Operation
System Operation Status
Maintenance
Function Checks
System Faults/Errors
System Monitoring
Wi-Fi Conguration
System Registration
HIVE Solar App Features
Emergency Situations
Emergency Handling Plan
Fire
Leaking Batteries
Wet Batteries
Damaged / Decommissioning Battery
Warranty Conditions
Safety Data Sheets
Contents
1
1.1
2
3
3.1
3.2
3.3
3.4
4
4.1
4.2
5
5.1
5.2
5.3
6
6.1
6.2
6.3
6.4
6.5
7
8
1
1
3
5
6
7
7
8
10
10
10
11
11
13
14
20
20
20
20
21
21
21
28

1www.hivesolar.com.au
2
Following the Installation of the HIVE Solar Battery, please ensure the below checklist
is completed and a record of the same is shared with your system provider. It is also
recommended that installers retain records of the equipment installed.
Installation & Commissioning Checklist
(For Installers Only)
No. Items Description
1System Provider (Contact details)
2Primary Batteries Model No – Storion-SMILE-B3 (2.9 kWh)
S/N –
3Secondary Batteries
Model No – M4856-P (2.9kWh)
No. of batteries –
S/N –
S/N –
S/N –
S/N –
S/N –
4Energy Meters Model No – ACR10R
No. of Meters –
5Total Battery Storage Capacity (kWh)
6UN Number UN 3480 / UN 3481
7Date of Installation & Commissioning
8
Firmware Versions
Inverter
EMS
BMS
9Initial System Settings As prescribed by Manufacturer
(Alpha ESS)
10
Verication – Normal System Operation N/A
Is the Battery Charging? (Y/N)
Is the Battery Discharging (Y/N)
11
If Backup/UPS is Connected, does the
battery discharge towards connected loads
with Utility grid is turned off? (Y/N)
12
DC Connections – Is there any high
resistance at the junction of the DC
cables & battery terminals? (Y/N)
CHAPTER 1

2
OWNERS MANUAL
Take the sting out of your energy bills
Following the Installation of the HIVE Solar Battery, please ensure that the system
owner or nominated representative is provided the following information.
• Demonstration of the System shut-down & Start-up procedures.
• Introduction to the system manual.
• Explanation of the Alarm/Faults that may arise with the system (Section 2.3).
• Contact details of Manufacturer/ system provider.
• Basic System Operation & design principals.
Further, ensure that a copy of the below customer acknowledgement is provided to the
system provider for installation records.
Customer Acknowledgement
I, ……………………………………………….......…………………(Customer)
acknowledge that …………………………………………………...(System Provider)
have attended my property and conducted the requested work. I conrm that
the installer attending my property has completed the installation based on his/
her recommendation for the most efcient energy production, provided me all the
information as per the induction requirements (Section 1.1) and I conrm that I have
agreed to this install location.
Customer’s Signature: Installer’s Signature:
Date: Date:
1.1 Induction requirements (For Installers Only)

3www.hivesolar.com.au
3
The HIVE Solar Battery is an energy storage system (BESS) used to store electrical
energy. Improper use of this system poses a risk of injury or death to the user or third
party, as well as damage to the product. The storage system must always be operated
as per the recommendations within this Owner’s Manual.
Danger
Danger to life due to high voltages of battery and electric shock:
• Only qualied personnel who are equipped with the suitable specialist
training, knowledge and experience are permitted to install and debug the system.
Before performing any work on the inverter or battery pack, please disconnect the
inverter from all voltage sources as described in this document.
• The Electrician should always wear the right Personal Protective Equipment
(PPE – Level 1) while operating the Energy Storage system.
• Do not touch any uninsulated DC cables, as this may result in electrical shock
or injury.
• Do not open the inverter and battery or modify any of the protective devices.
• Do not dispose of batteries in re as the batteries may explode.
• Only use the battery system in its original state, without any unauthorised
modications and when it’s in proper working order.
• Incorrect operation puts you and others at risk and could cause material damage
and potential injuries.
• Do not use the battery system in potential explosive environments.
• Never block, modify or alter any electrical protective devices such as AC Circuit
breakers, isolators or electrical cabling.
• Never attempt to repair the system yourself or using the services of a third-party
electrician as this may result in injury or may void the product warranty.
Important Safety Precautions
CHAPTER 2

4
OWNERS MANUAL
Take the sting out of your energy bills
• Ensure that all relevant local and national regulations are observed, and authorized
electrician is responsible for adhering to these regulations.
Warning
Risks of chemical burn electrolyte or toxic gases:
The battery modules installed in the BESS are protected by multiple electrical
protection devices and can be operated safely during standard operation. However,
there is a potential for the electrolyte leakage from the battery pack as well as from
toxic gases if damaged mechanically or break down. Therefore, it is recommended to
proceed as follows;
• Do not install the system in extreme low/high temperatures or humidity exceeding
the permitted range.
• Do not place heavy objects on top of the system or mechanically damage the
batteries (by piercing, puncturing or deforming it).
• Do not short circuit the battery module or allow them to come in contact with metal.
• Do not continue to use the battery module after a short-circuit.
• Do not install the battery pack in the vicinity of any equipment containing ammable
gases or liquids.
• If moisture penetrates the system (e.g. due to casing damage), please do not
operate the system. Contact Alpha ESS immediately for further troubleshooting.
• If you come into contact with the electrolyte, please wash affected area with water
immediately, and consult a doctor immediately.
Risk of injury by hoisting or falling system:
• Inverters and batteries are heavy and can cause personal injury if the inverter or
battery is improperly lifted or dropped during transport or when attached or removed
from walls.
• Lifting and transporting Storion-SMILE-B3/M4856-P must be conducted by more
than 1 person.

5www.hivesolar.com.au
4
The HIVE Solar battery is a modular battery solution intended for residential solar
storage and is capable of being expanded from 2.9 kWh to 17.4kWh. It has an all-
in-one design that is popular with installers and homeowners, as it has been pre-
engineered to minimise installation time and designed with the end-consumer’s
convenience in mind.
It is an AC coupled all-in-one battery energy storage system (BESS), designed to
achieve the optimal usage of renewable energy. It utilises excess Solar PV generation
to intelligently charge and discharge the battery, and can operate under automatic,
manual and time-of-use (ToU) modes. Under the automatic mode, the HIVE Solar
battery will store surplus energy into the battery and discharge towards connected
loads to avert consumption from the Utility Grid. It is equipped with three LEDs and is
designed to be easy to interact, stable, safe, and reliable.
In addition, it allows the consumer the exibility to add on more battery units in the
future, based on their energy needs. The simple plug-and-play installation allows the
installer to connect the additional storage units in quick succession and reduce overall
time spent on-site.
The HIVE Solar Batteries use the safest battery chemistry available on the market –
Lithium Iron Phosphate (LFP). As an additional safeguard, software integration is used
to monitor and protect the battery from any potential damage.
The Hive Solar Battery has two separate components,
• Primary Unit (Storion-SMILE-B3) – Battery pack with an Integrated Inverter.
• Secondary Unit (M4856-P) – Battery pack only (optional)
Primary Unit (Storion-SMILE-B3)
• AC-Coupled
• 2.9 kWh battery with integrated
3 kW inverter
• Modular design
• Easy install and low maintenance
• 24/7 monitoring
• Blackout protection (UPS)
– Optional Add on
HIVE Solar Batteries
Fig 1.1 Primary Unit (Storion-SMILE-B3)
CHAPTER 3
Battery Display
Com
Fault
Normal

6
OWNERS MANUAL
Take the sting out of your energy bills
Secondary Unit
(M4856-P Expansion pack)
• 2.9 kWh battery only
• Modular design
• Easy install & low maintenance
**Cycle Life/Performance dependent on temperature conditions, expected to be limited when temperature drops
below 0°C or above 40°C.
Inverted Technical Specications
Max AC Output Power 3000 W
Max AC Input Power 3000 W
Operating Temperature Range -10 °C ~ 50 °C, 0 °C ~ 40 °C (1C)
Warranty 5-year Product Warranty, 10 Year Battery
Warranty
Max AC Input Current 13 A
Nominal AC Input Voltage 230 V
Battery Voltage Range 40 ~ 58 V
Max Charging/Discharging Current 60 A
Max Charging/Discharging Power 3000 W
Phase Single – Phase
Nominal AC Output Voltage 230 V
Grid Voltage Range 180 ~ 270 V
Rated Frequency 50 / 60 Hz
Backup UPS
Dimensions (Storion SMILE B3) 610 mm x 236 mm x 625 mm
Weight 45 kg
Battery Technical Specications
Cell Technology Lithium Iron Phosphate (LFP)
Module Capacity 2.9 kWh
Usable Capacity 2.8 kWh
Depth of Discharge (DoD) 96%
Module Nominal Voltage 51.2 V
Max Short -circuit Current 200 A
Cycle Life 10 000**
Max Charging/Discharging Current 56 A (1C)
3.1 Technical Specications
Fig 1.2 Secondary Unit (M4856-P)
State
LED Ring

7www.hivesolar.com.au
The system is designed to operate based on the data measured by the Grid and PV
CTs. The former constantly measures the Electricity consumption of the house and the
latter measures the power generated by the Solar PV system.
When the Solar production > House Loads, the surplus power is stored within the
batteries. When the batteries reach their peak capacity, the surplus is exported to the
Utility grid. For example, if Solar production is 5 kW and the house loads are 3.5 kW,
then the battery is charged at 1.5 kW.
When the House Loads > Solar Production, the battery discharges to cover the decit
between the two. For example, When the Solar Production is 3 kW and the House
loads are 4 kW, then the Battery will discharge 1 kW.
The system must be turned On/Off in the correct sequence to avoid any damage.
Switching on:
• Turn on the Main Switch – Energy Storage (C20, Battery) within the switchboard.
• Turn on the Solar PV Inverter Main Switch within the switchboard.
• If AC Isolator is connected on Grid side, switch it on.
• Short press the Power button on the Primary Unit until the normal LED turns on.
• If a Secondary Unit is/are installed, short press the Power button on all Secondary
Units until the LED indicators light up.
3.2 Operating Principle
3.3 System Operation
Fig 1.3 Storion-SMILE-B3 System
Monitoring
Device
PV
Panels
PV
Inverter
PV
CT
Grid
CT
Utility
Meter
Grid
Normal Loads
Critical Loads
HIVE
Cloud
HIVE
Battery
Este manual sirve para los siguientes modelos
1