The battery charger doesn’t work
1. The battery charger is not con-
nected to the power supply
⇒Connect the charger to a supplied
electric socket.
2. The charger has the power switch
in position 0
⇒Move the power switch in position 1.
3. The battery charger has the Red
LED blinking
⇒The battery charger is in error con-
ditions, verify the alarm tables and
solve the issue by following the re-
lated instructions (see section 5.3.5 at page
32).
4. The battery charger plugged in and
turned on does not activate the
Green LED (electrical continuity)
⇒Replace the battery charger.
5. The battery charger plugged in and
turned on with battery inserted
does not activate the Red LED
(charging)
⇒Make sure the battery is properly
positioned inside the slot and the
terminals have a good contact.
The battery may be already
charged.
The display shows an alarm message
1. The display shows an alarm mes-
sage
⇒Check what alarm message is
shown and solve the related issue
by following the proper instructions
(see section 5.6.1 at page 36).
The machine has a very limited working autonomy
1. The battery is discharged ⇒Perform a complete charge cycle.
2. The battery have been working for
several cycles
⇒Replace the battery.
9