High Voltage CDS Series Guía

Safety,Operation,andProcedureInstructionsfortheCDSSeriesof
CapacitorDischarge/HipotCableFaultLocators
Danger- Lethal Voltages:
Equipment to be used by trained personnel only
This Operator Manual contains instructions for the operation of a High Voltage power source. The operator of this equipment
must use good judgement and follow all safety precautions noted in this guide to ensure the protection of himself and others in
close proximity to the test area. Failure to follow the instructions could result in injury or
death. Proper grounding of the test set must be done prior to connecting this
unittoapowersource.
CD
S
SERIES

OperatorManual
©HIGH VOLTAGE, INC.
31CountyRoute7A
Copake,N.Y.12516
Phone518/329-3275• Fax 518/329-3271
http://www.hvinc.com

LAST SAVED 1/27/2009 10:45 AM, T:\PRODUCT\DOCUMENTS\Manuals\CDS\MANcdsURa_tdr1_2k9.doc
TableofContents
About the Operator Manual 1
SECTION 1
General Information 2
Theory of Operation 2
Features and Specifications 3,4
Controls and Indicators 6,7
SECTION 2
Setting up the Equipment 8
Operating the Equipment 9-17
Hipot / Burn Mode 9-11
Capacitor Discharge Fault Locating (Thumping) 12-14
Capacitor Discharge Fault Locating (TDR) 15-17
Blank Page for Notes 18
SECTION 3
Performing Special Operations 19
Miscellaneous 19
Return Material 20
Warranty 21,22

OPERATOR MANUAL
- 1 -
AbouttheOperatorManual
Important
ThisOperatorManual describesthefeatures andsafe operation
ofaHigh VoltageTestSet.The instructions areintended tobe
clear andsimple, but theoperator must betrained and qualified
according to established procedures forthe useof this typeof
equipment.
This Operator Manual is organized to provide information on the CDS Series in steps that
familiarizethe newoperator with theentire scopeof operation of thistest set.
Section1: Specifications andControls.
Section2: Setup andOperation.
Section3: Performing SpecialOperations.
TheFunctions,Features,andSpecifications oftheCDSSeriesofCapacitorDischarge/HipotCableFault
LocatorsarealsodiscussedintheCDSBrochureavailablefromHighVoltage,Inc.

OPERATOR MANUAL
- 2 -
GeneralInformation
Thissection familiarizes theoperator withthe features andspecificationsof the
CDS Series of Capacitor Discharge/Hipot Cable Fault Locators manufactured by HIGH
VOLTAGE, INC.
Operation of this unit with standard TDR fault locating devices is possible using the internal Arc
Reflection Filter.
TheoryofOperation
With the use of buried underground cables in primary feed electrical installations, it is necessary to
locate faults and repair the cable the cable as quickly as possible to restore power to affected
areas. The CDS Series of Capacitor Discharge/Hipot Cable Fault Locators uses an energy
storage capacitor to provide a pulse of energy to create an audible sound at the fault location for
tracing. HVI CDS series fault locators all have built in Arc reflection filters for use with most TDR’s
(RADAR)on the marketat thumpvoltages upto 25 kV.
SECTION
1

OPERATOR MANUAL
- 3 -
FeaturesandSpecifications
The CDS Series of cable fault locating test sets provide continuously adjustable output voltages for the test
and location of faults in primary cables. The constant energy design provides the maximum energy at the
lowestvoltage to quickenfault locationwhile notoverstressing the cablesand terminations.
Standardfeatures ofthe CDSSeries of CapacitorDischarge/Hipot FaultLocator
•Continuouslyadjustable output voltage
•“Zero Start” Interlock provision
•Singlerange volt meter
•Singlerange current meter
•Single-cycleor continuous CapacitorDischarge operation
•Adjustabledischarge timing, 3-9 seconds
•MotorizedOutput VoltageTapSwitch
•Manuallyoperated Coupler Switchwith Radarand Directposition
•Twointernal dischargesolenoids, one forthe outputcable, one forthe internalcapacitorbank
•Onepiece design
•Transitprotected meters preventmeter damagebetween test sites
•Shieldedhigh voltage outputcables includedon all models.
•4 AWG Braided ground cable forsecure groundconnection

OPERATOR MANUAL
- 4 -
OPTIONS AVAILABLE
•Storage Reel system available forOutputand GroundCables
•CDS-36available with 3.2kJdischarge capacitor

OPERATOR MANUAL
- 5 -
CDS MODEL SPECIFICATIONS
See last page of parts list for
Specifications

OPERATOR MANUAL
- 6 -
DISCHARGE
SINGLE
CONTINUOUS
MODE
PULSE
OPERATING
HIPOT/
BURN
MODE
CAP
DISCHARGE
OUTPUT
ADJUST
HEATER
MAIN
POWER
ON
OFF
STOP START
50
40
30
20
10
0
60
70
80
90
100
MODEL CDS-36 CONSTANT ENERGY CAPACITOR DISCHARGE SYSTEM
COUPLER MODE
DIRECT RADAR
OFF
OUTPUT TAP
18kV OFFOFF
9kV 36kV
INTLK
EXT DISCHARGE
TIMING
3 SEC 9 SEC
Figure1CDS36U Seriesfront panel controls.
G
S
R
E
M
E
E
N
C
Y
T
O
P
HEATER
MAIN
POWER
MODEL CDS-2010
DISCHARGE
MODE MODE
OPERATING
SINGLE
PULSE HIPOT/
BURN
CONTINUOUS CAP
DISCHARGE
OUTPUT
ADJUST
STOP START
CONSTANT ENERGY CAPACITOR DISCHARGE SYSTEM
50
40 60
70
80
90
100
30
20
10
0
ON
OFF
INTLK
EXT
DIRECT
COUPLER MODE
RADAR
OFF 10kV
OUTPUT TAP
OFF
5kV 20kV
OFF DISCHARGE
TIMING
3 SEC 9 SEC
Figure2CDS20U Seriesfront panel controls.

OPERATOR MANUAL
- 7 -
MAIN POWER
The MAIN POWER circuit breaker provides the power to the control and power circuits. The MAIN POWER
pilot light will light when the power is on and voltage is available through the input line cord. The power
supplied to the input line cord must be from a grounded source rated to match the input power specifications
notedin Table-1.
HEATER
The HEATER circuit provides assistance in keeping the internal components from accumulating moisture in
dampenvironments. The pilotlight will illuminatewhen the circuitis powered.
START/STOP
The START/STOP pushbuttons activate (de-activate) the high voltage power circuits. The LED indicators
provide long life positive indication of the circuit status. The RED (START) LED lights when high voltage is
energized, the GREEN (STOP) LEDlightswhen the highvoltage isde-energized.
OUTPUT ADJUST
The OUTPUT ADJUST control variable transformer sets the output voltage. The 0-100% markings on the
knob indicate the low to high setting. The control must be at ZERO (0) to energize the high voltage circuits.
The output control must always be returned to zero at the completion of testing, prior to de-
energizing the output.
VOLTMETER
The KILOVOLT METER indicates the output voltage. 1-% precision resistors minimize the need for re-
calibrationdue to agingshift.
CURRENT METER
The CURRENT METER provides output current readings for the HIPOT/BURN function and capacitor
charge current in CAPACITOR DISCHARGE mode.
CAPACITOR DISCHARGE MODE
The CAPACITOR DISCHARGE MODE switch presets the control circuits for a single pulse (for use with
TDR)or allows thecircuit torun continuouslyin pulsemode.
OPERATING MODE
The OPERATING MODE switch controls the connection of the capacitor discharge bank and capacitor
discharge solenoids. The HIPOT position is used for high voltage testing without the energy discharge
capacitors in the circuit. The HIPOT mode also connects a current limiting reactor for burning down cables
and limit follow through current in a fault. The CAPACITOR DISCHARGE mode for fault locating cable
connectsthe capacitorbank intothe high voltage circuit and enablesthe dischargesolenoids.
Este manual sirve para los siguientes modelos
6
Tabla de contenidos
Manuales populares de Electricidad industrial de otras marcas

S&C
S&C Vista SD Manual de usuario

Murata
Murata GRM0335C2A7R3CA01 Series Manual de usuario

Siemens
Siemens 3VA9988-0BM10 Manual de usuario

Siemens
Siemens SITRANS LVS100 Manual de usuario

Murata
Murata GRM32ER60G227ME05 Series Manual de usuario

Siemens
Siemens SENTRON SUPERSWITCH 3KL82 Series Manual de usuario