Hi-flying HF2111A Manual de usuario

HF2111A GPRS DTU User Manual
http://www.iotworkshop.com - 1 -
HF2111A
GPRS DTU User Manual
V 1.0
Overview of Characteristic
Support GPRS(850/900/1800/1900MHz)
Support RS232/RS485 to GPRS Data Transmission, UART baud rate Up to 460800bps
Supports Max 3 Channel TCP/UDP connections, Each Connection Supports 1400 Bytes of Data
Cache
Support Multiple Working Modes: Network Transparent Transmission Mode, HTTP Mode
Support IOTService Tool, Remotely and Dynamically Modify Module Parameters
Support SMS AT Command Configuration
Supports Registration Packet, Heartbeat Packet Function, and Packet Supports Combination of
ICCID, IMEI, IMSI, Software Version, GPRS Connection Status.

HF2111A GPRS DTU User Manual
http://www.iotworkshop.com - 2 -
Support NTP
Support Modbus TCP to Modbus RTU
Support IOTBridge for Remote Control and Config
Support IOTBridge Working Time Setting, For Example, Only Works From 10:00 to 10:30 to Save
the Data Traffic
Support UART, Network OTA Upgrade Firmware
Size: 95 x 65 x 25mm
9~36VDC Wide Power Supply

HF2111A GPRS DTU User Manual
http://www.iotworkshop.com - 3 -
TABLE OF CONTENTS
TABLE OF CONTENTS....................................................................................................................3
LIST OF FIGURES............................................................................................................................4
LIST OF TABLES .............................................................................................................................4
1. PRODUCT OVERVIER ........................................................................................................5
1.1. General Description.........................................................................................................5
1.2. Device Parameters...........................................................................................................5
1.3. Key Applications..............................................................................................................6
2. HARDWARE INTRODUCTION ...........................................................................................7
2.1. Appearance ......................................................................................................................7
2.2. HF2111A Interface............................................................................................................8
2.3. RS232 Interface................................................................................................................9
2.4. RS485 Interface................................................................................................................9
2.5. Mechanical Size ...............................................................................................................9
2.6. Product Order Information............................................................................................10
APPENDIX A: CONTACT INFORMATION....................................................................................12

HF2111A GPRS DTU User Manual
http://www.iotworkshop.com - 4 -
LIST OF FIGURES
Figure 1. HF2111A Appearance .....................................................................................................................7
Figure 2. HF2111A Interface...........................................................................................................................8
Figure 3. RS232 Pin Defination(Male/Needle Type).......................................................................................9
Figure 4. HF2111A Mechanical Size.............................................................................................................10
Figure 5. HF2111A Product Order Information.............................................................................................11
LIST OF TABLES
HF2111A Technical Specifications.........................................................................................................5
HF2111A Interface Definition..................................................................................................................8
RS232 Interface......................................................................................................................................9
HISTORY
V 1.0 12-07-2018. First Version

HF2111A GPRS DTU User Manual
http://www.iotworkshop.com - 5 -
1.PRODUCT OVERVIER
1.1. General Description
The HF2111A support GPRS/GSM
The HF2111A support TCPIP protocol, with its RS232/RS485 interface, it make traditional UART
device easy connecting to IOT.
1.2. Device Parameters
HF2111A Technical Specifications
Item
Parameters
Wireless Parameter
GPRS Band
GSM850, EGSM900, DCS1800, PCS1900
GPRS Transmit
Power
GPRS transmit power GSM850/EGSM900: 5dbm~32.5dbm
DCS1800/PCS1900: 0dbm~29.5dbm
GPRS Receiving
Sensitivity
<-108.5dBm
GPRS Connection
Feature
GPRS multi-slot level is 10 (default)
GPRS mobile station level B
GPRS Data
Characteristics
GPRS data downlink transmission: up to 85.6 kbps
GPRS data uplink transmission: up to 85.6 kbps
Encoding format: CS-1, CS-2, CS-3 and CS-4
GPRS Antenna
Interface
Characteristic
Impedance
50Ω
Serial Port
Port Number
1
Interface Standard
RS232: DB9
RS485: 5.08mm connector
Choose either RS232 or RS485.
Data Bits
7,8
Stop Bit
1,2
Check Bit
None,Even,Odd
Baud Rate
TTL:2400 bps~460800 bps
Flow Control
No Flow control
Half-Duplex(RS485)
Hardware RTS/CTS、DSR/DTR(RS232)

HF2111A GPRS DTU User Manual
http://www.iotworkshop.com - 6 -
Software
Configuration
Serial AT Command
IOTService Serial Port Configuration Software
IOTService Network Configuration Software
Firmware Upgrade
UART or OTA Upgrade
Basic Parameter
SIM Card
Standard SIM card(1.8V/3V)
Size
95mm x 65mm x 25mm
Operating Temp.
-40 ~ 85°C
Storage Temp.
-45 ~ 105°C, 5 ~ 95% RH(no condensation)
Input Voltage
9~36VDC
Working Current
~300mA@9V
1.3. Key Applications
The HF2111A module connects the serial device to the Internet and conforms to the TCP/IP
protocol for transmitting serial data.
⚫Remote device monitoring
⚫Production asset tracking and monitoring
⚫Security field
⚫Industrial sensors and controllers
⚫Health medical equipment
⚫ATM equipment
⚫Data acquisition equipment
⚫UPS power management equipment
⚫Telecommunication equipment
⚫Data display device
⚫Hand-held device
⚫Attendance system and terminal equipment

HF2111A GPRS DTU User Manual
http://www.iotworkshop.com - 7 -
2.HARDWARE INTRODUCTION
HF2111A is a GPRS solution for serial device networking. Data transmission via GPRS makes
product integration very easy. This product meets EMC Class B security level and can pass relevant
certification tests in various countries.
2.1. Appearance
Figure 1. HF2111A Appearance

HF2111A GPRS DTU User Manual
http://www.iotworkshop.com - 8 -
2.2. HF2111A Interface
Figure 2. HF2111A Interface
HF2111A Interface Definition
Function
Name
Description
External
Interface
DC
DCPower 9~36V Input
RS485/RS232
RS485 A+ Connector
RS485 B- Connector
RS232 Rxd Connector
RS232 Txd Connector
Use either RS485 or RS232(Can not work
both)
SIM Card
Standard Sim Card Slot
Earth
Connect to Protect GND
Antenna
GPRS SMA Antenna
RS232
9-PIN RS232
LED
Indicator
NET
Network Status LED(Function is reserved)
Off: No network connection
2s On -> 2s Off: Network connection is OK
100ms On -> 100ms Off: Network is in
transferring

HF2111A GPRS DTU User Manual
http://www.iotworkshop.com - 9 -
Function
Name
Description
Active
UART Data Bi-Color LED
Blue On: UART data output
Green On: UART data input
Power
3.3V Internal Power Supply LED
Button
Reload
Long press 3 seconds down and loose to
restore parameters to factory setting
Switch
Protect
Parameter Protect (Function is Reserved)
2.3. RS232 Interface
Device serial port is male(needle), RS232 voltage level(can connect to PC directly), Pin Order is
cosistent with PC COM port. Use cross Cable connected with PC(2-3 cross, 7-8 cross, 5-5 direct), see
the following table for pin defination.
Figure 3. RS232 Pin Defination(Male/Needle Type)
RS232 Interface
Pin Number
Name
Description
2
RXD
Receive Data
3
TXD
Send Data
5
GND
GND
7
RTS
Request to Send
8
CTS
Clear to Send
2.4. RS485 Interface
RS485 use two wire links, A(DATA+), B(DATA-). Connect A(+) to A(+), B(-) to B(-) for communication.
Suggest to connect GND together when interference is very severe.
The RS485 interface support maximum 32 485 device, device. The cable maximum length is 1200
meters. Need to add 120Ohm terminal resistor for over 300 meters.
2.5. Mechanical Size
The dimensions of HF2111A are defined as following pictures(mm):
Tabla de contenidos