hestan KGC30-LP Manual de usuario

INDOOR COOKING
Drop-in Gas Cooktop
KGC
Installation Manual

SAFETY DEFINITIONS
THIS INDICATES THAT DEATH OR SERIOUS INJURY MAY OCCUR
AS A RESULT OF NOT OBSERVING THIS WARNING.
THIS INDICATES THAT MINOR OR MODERATE INJURY MAY
OCCUR AS A RESULT OF NOT OBSERVING THIS WARNING.
THIS INDICATES THAT DAMAGE TO THE APPLIANCE OR
PROPERTY MAY OCCUR AS A RESULT OF NOT OBSERVING THIS
WARNING.
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE
INSTALLING OR USING YOUR APPLIANCE TO REDUCE THE RISK OF FIRE,
BURN HAZARD, OR OTHER INJURY. KEEP THIS MANUAL FOR FUTURE
REFERENCE.
CAUTION
NOTICE
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
WHAT TO DO IF YOU SMELL GAS:
1) Do not try and light any appliance.
2) Do not touch any electrical switch.
3) Do not use any phone in your building.
4) Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
5) If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency, or
the gas supplier.
IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
INSTALLER: LEAVE THIS MANUAL WITH THE OWNER OF THE APPLIANCE.
HOMEOWNER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

©2019 Hestan Commercial Corporation
1
EN
When properly cared for, your Hestan appliance will provide safe, reliable service for many
years. When using this appliance, basic safety practices must be followed as outlined below.
IMPORTANT: Save these instructions for the local Gas or Utility Inspector’s use.
INSTALLER: Please leave these Installation Instructions with the owner.
OWNER: Please retain these Installation Instructions for future reference.
This cooktop is designed for residential use only.
Do NOT install this cooktop outdoors.
SAFETY PRECAUTIONS - BEFORE YOU BEGIN
ELECTRICAL SHOCK HAZARD
Disconnect power before installing or servicing appliance. Before turning
power ON, be sure all controls are in the OFF position. Failure to do so
can result in death or electrical shock.
ELECTRICAL GROUNDING
This appliance must be grounded. Grounding reduces the risk of electric
shock in the event of a short circuit. Read the ELECTRICAL CONNECTIONS section of this
manual for complete instructions.
TABLE OF CONTENTS
1 SAFETY PRECAUTIONS - BEFORE YOU BEGIN
2 MODELS AND RATINGS
3 RATING LABEL
3 REGULATORY / CODE REQUIREMENTS
4 LOCATION AND INSTALLATION
12 GAS CONNECTION
16 ELECTRICAL CONNECTION
17 VENTILATION REQUIREMENTS
18 CONVERSION
22 FINAL SETUP
25 PARTS LIST
25 SERVICE

©2019 Hestan Commercial Corporation
2
EN
MODELS AND RATINGS
COOKTOP MODELS
MODEL NO. DESCRIPTION CIRCUIT BREAKER
REQUIRED
KGC30 NG / -LP 30” DROP-IN GAS COOKTOP 15 Amp
KGC36 NG / -LP 36” DROP-IN GAS COOKTOP 15 Amp
RATINGS
KGC 30 POWER Btu/h with NG at
5inch WC POWER Btu/h with LP at
10inch WC
Zones max flow rate min flow rate max flow rate min flow rate
Front right 8000 1300 6000 1300
Front left 8000 1300 6000 1300
Rear left 10500 2200 10500 2200
Rear right 10500 2200 10500 2200
Center – simmer 850 850
Center – main flame 20000 20000
KGC36 POWER Btu/h with NG at
5inch WC POWER Btu/h with LP at
10 inch WC
Zones max flow rate min flow rate max flow rate min flow rate
Front right (Stacked B) 15000 1300 15000 1300
Front left (Stacked B) 15000 1300 15000 1300
Rear left (Stacked B) 15000 1300 15000 1300
Rear right (Stacked B) 15000 1300 15000 1300
Center – simmer 850 850
Center – main flame 20000 20000

©2019 Hestan Commercial Corporation
3
EN
REGULATORY / CODE REQUIREMENTS
Installation of this cooking appliance must be made in accordance with local codes. In the
absence of local codes, this unit should be installed in accordance with the National Fuel
Gas Code
ANSI Z223.1/NFPA 54
, Natural Gas and Propane Installation code
CSA B149.1
, or
Propane Storage and Handling Code
B149.2
.
All Electrical Components must be electrically grounded in accordance with local codes or
in the absence of local codes with the National Electrical Code
ANSI/NFPA 70
, or Canadian
Electrical code
CSA C22.1
.
STATE OF MASSACHUSETTS
Massachusetts requires all gas be installed using a plumber or gas fitter carrying the appropriate
Massachusetts license. All permanently installed natural gas or propane installations require a
T-handle type manual gas valve be installed in the gas supply line to this appliance. Flexible gas
connector must not be longer than 36” [91.4 cm].
CALIFORNIA PROPOSITION 65 - WARNING
WARNING: This product can expose you to chemicals including carbon
monoxide, which is known to the State of California to cause birth defects or
other reproductive harm.
For more information, go to www.P65Warnings.ca.gov.
RATING LABEL
There are two rating labels on the unit. The main label contains important information about your
Hestan appliance such as the model and serial number, gas type and electrical rating.
Both rating labels are located in the bottom of the cooktop unit. Make sure you record your
model number and serial number for future use. The second rating label contains information
about the gas requirements and usage.
If service is necessary, contact Hestan
Customer Service with the model and serial
number.
Figure 1.
Rating Label Locations
KGCXX
HESTAN COMMERCIAL CORP.
ANAHEIM, CA - USA
XXX XXXXXX
xxxxxxxxx
xxxxxxxxx
xxxxxxxxx
Figure 2.
Sample Rating Label

©2019 Hestan Commercial Corporation
4
EN
LOCATION AND INSTALLATION
PLACEMENT
Check location where cooktop will be installed. The location should be away from strong drafty
areas, such as windows, doors and strong heating vents or fans.
UNPACKING
Do not remove the plastic film covering the stainless-steel surfaces. This film protects the finish
from scratches until the appliance is installed in its final position.
PREPARATION
Electrical grounding is required. See “ELECTRICAL CONNECTION” on page 16 .
Assure that electrical installation is adequate and in conformance with National Electrical Code,
ANSI/NFPA 70 - latest edition**, or Canadian Electrical Code, part 1 C22.1 (latest edition)*** and
all local codes and ordinances.
Assure that the gas connection conforms with local codes and ordinances. In the absence of local
codes, installations must conform with American National Standard, National Fuel Gas Code ANSI
Z223/NFPA 54 - latest edition** Canadian CAN/CGA_B 149.1 or CAN/CGA-149.2 latest edition**
GAS AND ELECTRICAL SUPPLY CLEARANCES
If not already in place, install a gas shut-off valve in an easily
accessible location for servicing of the cooktop. Make sure
all users of the cooktop know where this shut-off is located,
and how to shut off the gas. Any openings in the wall or floor
behind the appliance must be sealed. See
Figure 8
and
Figure 9
on page6 and 7 for cutouts and clearances.
CABINETRY
To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the surface
units should be avoided. If cabinet storage is to be provided,
the risk can be reduced by installing the required vent hood
that projects horizontally a minimum of 5” [12.7 cm] beyond the
bottom of the cabinets.
GAS
SUPPLY
TO
APPLIANCE
SHUTOFF VALVE
IN OPEN POSITION
Figure 3.
Gas Shut-Off Valve
Copies of the standards listed may be obtained from:
** National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02169-7471
*** CSA International
8501 East Pleasant Valley Rd.
Cleveland, OH 44131-5575

©2019 Hestan Commercial Corporation
5
EN
LOCATION AND INSTALLATION
(continued)
INSTALLING COOKTOP OVER OVEN
Only certain specified cooktop and oven models are approved for cooktop over oven installations.
Cooktops approved for this type of installation will have an approval label located on the outside
of the burner box. The label lists the cooktop and oven combinations that are approved for this
type of installation.
If you do not find this label, contact your dealer to confirm that the cooktop is approved for
installation over your model of oven.
COOKTOP DIMENSIONS
REGULATOR CLEARANCE
The regulator may mounted to the cooktop
directly or via a flexible (semi–rigid) stainless
steel gas hose with appropriate end fittings.
(See “GAS CONNECTION” on page 13 for
more information)
30” [76,2 cm]
3-1/2”
[8,9 cm]
20-15/16”
[53,3 cm]
Figure 4.
30” Model
36” [91,4 cm]
3-1/2”
[8,9 cm]
20-15/16”
[53,3 cm]
Figure 5.
36” Model
6-1/4"
[15.9 cm]
5-1/8"
[12.9 cm]
Figure 6.
Regulator clearance

©2019 Hestan Commercial Corporation
6
EN
LOCATION AND INSTALLATION
(continued)
COUNTERTOP
1) Chamfer all exposed edges of decorative laminate to prevent damage from chipping.
2) Radius corners of cutout and file to ensure smooth edges and prevent corner cracking.
3) Recommend 1/4”or 3/8” diameter drill in each corner.
4) For solid surface countertops, refer to countertop material manufacturer instructions.
SOLID SURFACE COUNTERTOPS
NOTICE
Important: For solid surface material
installations such as Surel™ and Corian®,
consult with solid surface manufacturer.
Apply heat reflective tape such as Scotch®
Aluminum Foil Tape #425 or #427 around the
cutout so that it folds over on the top and
sides.
DO NOT WRAP THE TAPE UNDERNEATH
THE COOKTOP.
Be sure the tape extends beyond the
outermost flange of the cooktop. All corners
should be covered with tape.
NEW INSTALLATIONS
For new installations, the
minimum cut-out size is
preferable.
Figure 7.
Solid Surface Protective Tape
Figure 8.
Cutout Requirements (1/2)
Cooktop
Model
A B C D
KGC30
MIN 28-1/2” [72.4 cm]
MAX 29” [73.7 cm]
MIN 19-1/2” [49.5 cm]
MAX 19-5/8” [49.8 cm]
MIN 19-1/2” [49.5 cm]
MAX 19-5/8” [49.8 cm]
MIN 2”
[5.0 cm]
MIN 3-1/2”
[9.0 cm]
KGC36
MIN 34-1/2” [87.6 cm]
[88.9 cm]MAX35”
MIN 2”
[5.0 cm]
MIN 3-1/2”
[9.0 cm]

©2019 Hestan Commercial Corporation
7
EN
LOCATION AND INSTALLATION
(continued)
A 13” [33 cm) Depth of unprotected overhead cabinets.
B 30” [76.2 cm] MIN. (KGC30)
36” [91.4 cm] MIN. (KGC36)
C 18” [47.7 cm] MIN. Height from countertop to nearest cabinet on either side of unit.
D 30” [76.2 cm ] MIN. (see Note*) Clearance from countertop to unprotected overhead surface.
E 5” [12.7 cm] MIN. Clearance from cut out to side wall on the left and right of the unit.
F From the back corner of cut-out to hole center 2-9/32” [5.8 cm].
G From the right corner of cut-out to hole center 2-19/32” [6.6 cm].
H From the back corner of cut-out to hole center 1-1/4” [3.2 cm]. Opening with oven under
cooktop.
I From the top of countertop to hole center 6” [15.2 cm]. Opening with oven under cooktop.
L Electric outlet from bottom of countertop and adjacent to the cabinet side 12” [30.5 cm].
– Hole 1-3/16” [3 cm].
* NOTE
• If cabinet has a drawer, a 5-1/4”[3.2cm] depth clearance from the top of the countertop to the
top of the drawer (or other obstruction) in base cabinet is required. The drawer depth may
need to be shortened to avoid interfering with the regulator.
• 24” [61 cm] min. clearance if bottom of wood or metal cabinets is protected by not less than
1/4” [0.6cm] flame retardant millboard covered with not less than No. 28 MSG sheet steel
0.015” [0.04cm] stainless steel, or 0.024” [0.06 cm] aluminum or 0.020” [0.05 cm] copper.
30” [76.2cm] min. clearance between top of cooking platform and bottom of unprotected
wood or metal cabinet.
Figure 9.
Cutout Requirements (2/2)

©2019 Hestan Commercial Corporation
8
EN
LOCATION AND INSTALLATION
(continued)
MOBILE HOME INSTALLATION
The installation of this cooktop must conform to the Manufactured Home Construction and
Safety Standards, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home
Construction and Safety;
Title 24 HUD part 280); or when such standard is not applicable, the Standard for
Manufactured Home Installations (Manufactured Home Sites, Communities and Setups), ANSI
A225.1 - latest edition, or with local codes.
In Canada, the installation of this cooktop must conform with the current standards CAN/
CSA-Z240 - latest edition, or with local codes.
The appliance should not be installed with a ventilation system that blows air downward
toward the cooktop. This type of ventilation system may cause ignition and combustion
problems with the gas cooking appliance resulting in personal injury or unintended operation.
Este manual sirve para los siguientes modelos
4
Tabla de contenidos
Idiomas:
Otros manuales de Placa de cocina de hestan

hestan
hestan KICS30 Manual de usuario

hestan
hestan KICS 36 Manual de usuario

hestan
hestan KIC series Manual de usuario