Henden 2712991 Instrucciones de funcionamiento

Inverter Heat Pump
INSTALLATION &
OWNER’S MANUAL
IMPORTANT
Please read carefully
CAUTIONS AND WARNINGS:
Installation and maintenance must be handled
by a professional pool builder/service agent.
Repairs should be carried out in a well
ventilated area.
Failure to follow these instructions and comply
with all applicable codes may cause serious
bodily injury and/or property damage.
This Inverter Heat Pump contains R32
refrigerant gas which is a flammable substance
under certain conditions.
Turn off the power during thunderstorms and
severe weather.
The Inverter Heat Pump must be positioned on a
concrete base. It is recommended that the frame
is secured using M10 bolts.
Do not lift the Inverter Heat Pump using the
water unions.

2HENDEN – INSTALLATION & OWNERS MANUAL

3HENDEN – INSTALLATION & OWNERS MANUAL
Contents
Inverter Heat Pump
Introduction 4
Helpful hints 4
In the box 5
Electrical set up 6
Installation 7
First time start up 10
Typical installation 13
Alternative installation options 14
Operation 21
App functionality 28
Specifications 31
Dimensions 32
Maintenance 33
Winterising 34
Troubleshooting 35
Error codes 36
Frequency conversion board fault 38
Exploded diagram (9kw/14kw/17kw/20kw) 40
Spare parts (9kw/14kw/17kw/20kw) 41
Exploded diagram (24kw/28kw) 42
Spare parts (24kw/28kw) 43
Warranty 44
Notes 45

4HENDEN – INSTALLATION & OWNERS MANUAL
INTRODUCTION
Thank you for purchasing a Henden
Inverter Heat Pump.
Harness the power of this high performing
heat pump. Built with inverter technology
for energy efficiency and designed
for super quiet operation, this sleek
and compact heat pump is perfect for
Australian residential pools.
HELPFUL HINTS
> The surroundings of the Henden Inverter
Heat Pump should be kept clear to avoid
restricting ventilation.
> Install the Henden Inverter Heat Pump in
a well ventilated, outside area.
> Regularly check the condensate hose for
blockages and clean as necessary.
> Ensure the Wi-Fi strength at the site of
installation is strong (more than -50dB is
recommended).
> Install the Henden Inverter Heat Pump in
line with the ventillation diagrams in this
manual.
> For a complete heating solution, pair
with a Henden 550 Micron Solar Pool
Cover. This addition helps reduce energy
consumption, heat loss and water
evaporation.

Henden Inverter Heat Pump
X4 rubber feet
X2 union tails
1.5 metre drain hose
Quick Start Guide
Inverter Heat Pump
QUICK START
GUIDE
Scan to view the complete installation manual:
CAUTIONS AND WARNINGS:
Keep the Henden Inverter Heat Pump
away from any potential fire source.
The Henden Inverter Heat Pump must be
placed in a well-ventilated area; it must not
be placed in an indoor or enclosed area.
Installation must be handled by a professional
pool builder/service agent.
Repair and disposal must be carried
out by manufacturer approved
service personnel.
Thank you for purchasing a Hen den Inverter Heat Pump.
Built with inverter technology for energy efficiency and designed for
super quiet operation. Harness the power of this high performing
heat pump and enjoy more time in the pool.
HELPFUL HINTS
• Prepare the outdoor installation area by
removing tree branches, debris or
anything that could restrict ventilation.
• Regularly check the condensate drain for any
blockages or debris build up. This will
ensure optimal drainage.
• Make sure there is water flowing through the
Henden Inverter Heat Pump when operating.
• To maximise efficiency, install the Henden
Inverter Heat Pump in line with the ventilation
diagrams depicted.
• If you intend to connect the Henden
Inverter Heat Pump to the Handy
Heat Pump app, ensure you have strong
Wi-Fi in the installation location. More than
-50Db is considered suitable for use.
IMPORTANT
Please read carefully
5HENDEN – INSTALLATION & OWNERS MANUAL
Inverter Heat Pump
IN THE BOX

6HENDEN – INSTALLATION & OWNERS MANUAL
ELECTRICAL SET UP
Always use a qualified electrician to perform any electrical work. A licensed
electrician must read the information before connecting.
The Henden Inverter Heat Pump must be earthed and equipotential bonded.
Ensure the power cable and circuit breaker are of suitable size for the heater
being installed. See specification sheet on page 27 for max input power.
Check that there is adequate voltage and current available at the heater
connection to run the unit. Voltage range should be 220–230 volts for single
phase. Voltage ranges outside these parameters will damage the Henden
Inverter Heat Pump.
Ensure power is disconnected during installation or service.
Always comply with the national and local electrical codes and standards.
Ensure electrical cable size is adequate for heater requirements at the
installation location.
1
2
3

7HENDEN – INSTALLATION & OWNERS MANUAL
Inverter Heat Pump
To begin, position the Henden Inverter
Heat Pump on solid level ground
outside. Do not place the unit in an
enclosed area.
Positioning the Henden Inverter Heat Pump
Check that there are no objects
blocking the air inlet and that the
minimum clearance guidelines
displayed are followed.
Place the 4 rubber feet supplied
under the Henden Inverter Heat Pump.
Ensure the Henden Inverter Heat
Pump is equipped with a circuit
breaker and electrical isolation switch.
700mm 700mm
700mm 300mm
INSTALLATION
1
2
3
4

8HENDEN – INSTALLATION & OWNERS MANUAL
Connecting the condensation drain
Locate the barb under the heater
and push the supplied drain hose
on securely.
Run the drain hose downhill to
a suitable location. For example, a
garden or nearby stormwater drain.
Note: the hose can drain up to
10 litres of condensation per hour.
1
2
INSTALLATION

9HENDEN – INSTALLATION & OWNERS MANUAL
Inverter Heat Pump
INSTALLATION
Using the 40mm tail supplied,
connect the inlet of the Henden
Inverter Heat Pump downstream,
after the pool pump and filter.
Create a flow bypass between the
inlet and outlet pipework to ensure
optimal efficiency. See an example
of this using 3 valves adjacent.
Using the 40mm tail supplied,
connect the outlet upstream before
any chlorinators, acid injection
or other chemical dosing systems.
Setting up the flow bypass
Connecting the pipework
1
2
1
Flow
Bypass

10 HENDEN – INSTALLATION & OWNERS MANUAL
FIRST TIME START UP
%
ON
ON
With the bypass valve fully open,
turn the pool pump on.
Check there are no water leaks
and verify adequate flow to and
from the pool.
Turn on the electrical power
supply to the Henden Inverter
Heat Pump. If hardwired, turn
on the isolation switch.
Press the power symbol on the
control panel. The Henden Inverter
Heat Pump will turn on within
a few seconds.
1
2
3
4
Powering the Henden Inverter Heat Pump
Este manual sirve para los siguientes modelos
3
Tabla de contenidos
Otros manuales de Bomba de calor de Henden
Manuales populares de Bomba de calor de otras marcas

Mitsubishi Electric
Mitsubishi Electric PUZ-SWM60VAA Manual de usuario

Dimplex
Dimplex LI 16I-TUR Guía del usuario

Carrier
Carrier WSHP Open v3 Guía de configuración rápida

TGM
TGM CTV14CN018A Manual de usuario

Carrier
Carrier 38MGQ Series Manual de usuario

Kokido
Kokido K2O K880BX/EU Guía de solución de problemas

Viessmann
Viessmann VITOCAL 300-G PRO Type BW 2150 Guía rápida

Carrier
Carrier 48EZN Manual de usuario

Viessmann
Viessmann KWT Vitocal 350-G Pro Series Instrucciones de funcionamiento

Ariston
Ariston NIMBUS Manual de usuario

Weishaupt
Weishaupt WWP L 7 Guía del usuario

GE
GE Zoneline AZ85H09EAC Manual de usuario