Helmer i Series Manual de usuario

Refrigerator Operation Manual
i.Series®and Horizon Series™ - Upright
360372/B
Laboratory
i.Series
iLR111, iLR120, iLR125, iLR245,
iLR256
Horizon Series
HLR111, HLR120, HLR125, HLR245,
HLR256
Pharmacy
i.Series
iPR111, iPR120, iPR125, iPR245,
iPR256
Horizon Series
HPR111, HPR120, HPR125, HPR245,
HPR256
Blood Bank
i.Series
iB111, iB120, iB125, iB245, iB256
Horizon Series
HB111, HB120, HB125, HB245, HB256

Document Updates
The document is furnished for information use only, is subject to change without notice and should not be construed as a
commitment by Helmer Scientic. Helmer Scientic assumes no responsibility or liability for any errors or inaccuracies that may
appear in the informational content contained in this material. For the purpose of clarity, Helmer Scientic considers only the most
recent revision of this document to be valid.
Notices and Disclaimers
Condential / Proprietary Notices
Use of any portion(s) of this document to copy, translate, disassemble or decompile, or create or attempt to create by reverse
engineering or otherwise replicate the information from Helmer Scientic products is expressly prohibited.
Copyright and Trademark
Copyright © 2018 Helmer, Inc. Helmer®, i.Series®, i.C³®, Horizon Series™, and Rel.i™ are registered trademarks or trademarks
of Helmer, Inc. in the United States of America. All other trademarks and registered trademarks are the property of their respective
owners. Helmer, Inc., doing business as (DBA) Helmer Scientic and Helmer.
Disclaimer
This manual is intended as a guide to provide the operator with necessary instructions on the proper use and maintenance of
certain Helmer Scientic products.
Any failure to follow the instructions as described could result in impaired product function, injury to the operator or others, or void
applicable product warranties. Helmer Scientic accepts no responsibility for liability resulting from improper use or maintenance of
its products.
The screenshots and component images appearing in this guide are provided for illustrative purposes only, and may vary slightly
from the actual software screens and/or product components.
Helmer Scientic
14400 Bergen Boulevard
Noblesville, IN 46060 USA
www.helmerinc.com
ISO 13485 CERTIFIED Part No. 360372/ Rev B
Document History
Revision Date CO Supersession Revision Description
A 03 NOV 2016 12280 n/a Initial release (all units with serial numbers 2035000 and greater).
B 12 JAN 2018 13277 B supersedes AUpdated hysteresis values in Table 3. Parameter Values
Updated Mute Active Alarms text to provide more detail
Updated Table 2. Application Icons
Updated Horizon Access Control content for clarity.
Updated Emergo Address
* Date submitted for Change Order review. Actual release date may vary.

Helmer Scientic i.Series® and Horizon Series™Refrigerator - Upright Operation Manual
360372/B 3
Contents
1 About This Manual ............................................................................................... 4
1.1 Safety Precautions and Symbols .................................................................................. 4
1.2 General Recommendations ...................................................................................... 5
2 Installation ...................................................................................................... 6
2.1 Location .....................................................................................................6
2.2 Placement and Leveling.........................................................................................6
2.3 Temperature Probes............................................................................................6
2.4 Chart Recorder (If Included)......................................................................................8
3 i.Series®Operation .............................................................................................. 10
3.1 Initial Power-Up ..............................................................................................10
3.2 Operation ....................................................................................................11
3.3 Change Temperature Setpoint ....................................................................................11
3.4 Set Alarm Parameters ......................................................................................... 12
3.5 Active Alarms ................................................................................................13
3.6 Mute and Disable Active Alarms..................................................................................13
3.7 Light Operation...............................................................................................14
4 Min/Max Temperature Monitoring .................................................................................. 15
5 i.Series®Access Control (Optional)................................................................................. 16
5.1 Set Up .....................................................................................................16
5.2 Open Refrigerator with Access Control ............................................................................ 16
6 Horizon Series Operation......................................................................................... 17
6.1 Initial Power Up .............................................................................................. 17
6.2 Display Minimum and Maximum Monitor Temperature Recordings....................................................... 17
6.3 Change Temperature Setpoint ................................................................................... 18
6.4 Set Parameter Values ......................................................................................... 19
6.5 Set Temperature Units .........................................................................................19
6.6 Temperature Calibration Offsets..................................................................................19
6.7 Set Alarm Setpoints (Parameters) ................................................................................ 20
6.8 Active Alarms ................................................................................................20
6.9 Mute and Disable Audible Alarms................................................................................. 20
6.10 Light Operation..............................................................................................20
7 Horizon Series™Access Control (Optional) .......................................................................... 21
7.1 Setup ......................................................................................................21
8 ProductSpecications ........................................................................................... 22
8.1 Operating Standards .......................................................................................... 22
9 Compliance .................................................................................................... 26
9.1 Regulatory Compliance ........................................................................................26
9.2 WEEE Compliance............................................................................................26
10 Preventive Maintenance .......................................................................................... 27
Appendix A......................................................................................................... 28
i.Series Parts....................................................................................................28
Appendix B......................................................................................................... 29
Horizon Series Parts ..............................................................................................29

Helmer Scientic i.Series® and Horizon Series™Refrigerator - Upright Operation Manual
360372/B 4
1 About This Manual
This manual provides information on how to use i.Series®and Horizon Series™upright laboratory, blood bank, and pharmacy
refrigerators. It is intended for use by end users of the refrigerator and authorized service technicians.
Models are indicated by a distinguishing model number that corresponds to the series, type, number of doors, and capacity of the
refrigerator. For example, “iLR125” refers to an i.Series Laboratory Refrigerator with 1 door and a capacity of 25 cu ft.
Generic references are used throughout this manual to group models that contain similar features. For example, “125 models”
refers to all models of that size (iB125, HB125, iLR125, HLR125, iPR125, HPR125). This manual covers all upright refrigerators,
which may be identied singly, by their size, or by their respective “Series”.
1.1 Safety Precautions and Symbols
Symbols found in this document
The following symbols are used in this manual to emphasize certain details for the user:
Task Indicates procedures which need to be followed.
Note Provides useful information regarding a procedure or operating technique when using Helmer
Scientic products.
NOTICE Advises the user against initiating an action or creating a situation which could result in damage to
equipment; personal injury is unlikely.
CAUTION Advises the user against initiating an action or creating a situation which could result in damage
to equipment or impair the quality of the products or cause minor injury.
WARNING Advises the user against initiating an action or creating a situation which could result in damage
to equipment and serious personal injury to a patient or the user.
Manufacturer
Authorized representative in the European Community
Symbols found on the units
The following symbols may be found on the refrigerator or refrigerator packaging:
CE Mark (European units only) Earth / ground terminal
Caution: Risk of damage to equipment or
danger to operator Protective earth / ground terminal
Caution: Hot surface Compliance with Restriction of Hazardous
Substances Directive
Caution: Shock / electrical hazard Product falls under the scope of the WEEE
(Waste Electrical and Electronic Equipment)
directive.
Caution: Unlock all casters
EC REP

Helmer Scientic i.Series® and Horizon Series™Refrigerator - Upright Operation Manual
360372/B 5
Avoiding Injury
Review safety instructions before installing, using, or maintaining the equipment.
♦Do not open multiple, loaded drawers at the same time.
♦Do not move a unit whose load exceeds 900 lbs / 408 kg (single-door units) or 1350 lbs / 612 kg (double-door units).
♦Before moving unit, ensure casters are unlocked and free of debris.
♦Never physically restrict any moving component.
♦Avoid removing electrical service panels and access panels unless so instructed.
♦Use manufacturer supplied power cords only.
CAUTION
Decontaminate parts prior to sending for service or repair. Contact Helmer or your distributor for decontamination
instructions and a Return Authorization Number.
1.2 General Recommendations
Intended Use
Helmer refrigerators are intended for the storage of blood products and other medical and scientic products.
General Use
Allow refrigerator to come to room temperature before switching power on.
During initial startup, high temperature alarm may sound while refrigerator reaches operating temperature.
CAUTION
Do not remove the cover from the condensate evaporator tray.
Initial Loading
Allow the refrigerator to reach room temperature before powering on. Allow chamber temperature to stabilize at the setpoint before
storing product.
Product Loading Guidelines
When loading your refrigerator, take care to observe the following guidelines:
♦Never load refrigerators beyond capacity.
♦Always store items within shelves, drawers or baskets.
♦ Temperature uniformity is maintained by air circulation, which could be impeded if unit is overlled, particularly at the top or
back. Ensure proper clearance is provided below the fan.
Note
Products stacked against back wall may obstruct air ow and affect performance of unit.

Helmer Scientic i.Series® and Horizon Series™Refrigerator - Upright Operation Manual
360372/B 6
2 Installation
2.1 Location
♦ Has a grounded outlet meeting the electrical requirements listed on the product specication label.
♦Is clear of direct sunlight, high temperature sources, and heating and air conditioning vents.
♦Minimum 8“ (203 mm) above, and minimum 3” (76 mm) behind.
♦ Meets limits specied for ambient temperature (15˚C to 32˚C) and relative humidity.
2.2 Placement and Leveling
CAUTIONS
• The evaporation tray located on the rear of the refrigerator may be hot. Do not use the tray as a handle.
• To prevent tipping, ensure the casters are unlocked, leveling feet (if installed) are lifted, and the doors are closed before
moving the refrigerator.
1. Roll refrigerator into place and lock casters.
2. Ensure refrigerator is level.
Note
Helmer recommends the use of leveling feet.
2.3 Temperature Probes
Probe bottle(s) along with a container of glycerin have been provided with this unit. The glycerin is used to create a solution which
simulates the product stored in the refrigerator. The product simulation solution temperature reects the product’s temperature
during normal operation.
Notes
• Temperature probes are fragile; handle with care.
• Number and location of probes varies by model.
• Remote probes may also be introduced through the existing top port or through the side port (if included).
CAUTION
Failure to ll probe bottles or keep probe bottles lled to the appropriate level may not allow the chamber temperature to
stabilize at the refrigerator setpoint or the chamber temperature to display higher or lower than the actual temperature.
Primary Monitor Probe
The primary monitor probe is located in the top right corner of the refrigerator.
Primary monitor probe with optional chart recorder probe

Helmer Scientic i.Series® and Horizon Series™Refrigerator - Upright Operation Manual
360372/B 7
Secondary Probe
The secondary probe is located in the lower right corner of the refrigerator.
Secondary probe
Fill Temperature Probe Bottle
Note
For each probe bottle, use approximately 4 oz. (120 mL) of product simulation solution (10:1 ratio of water to glycerin)
(Packet included in refrigerator box).
1. Remove all probes from bottle and remove bottle from bracket.
2. Remove cap and ll with approximately 4 oz. (120 mL) of product simulation solution.
3. Secure cap on bottle and place in bracket.
4. Replace probes, immersing at least 2” (50 mm) in solution.
Install Additional Probe Through Top Port
Top access port
1. Peel back putty to expose port.
2. Insert probe through port into chamber.
3. Insert probe into bottle.
4. Replace putty, ensuring a tight seal.
Install Additional Probe Through Side Port (If Included)
1. Remove interior and exterior plugs to expose side access port.
2. Insert probe through port into chamber.
3. Insert probe into bottle.
4. Ensure port is tightly sealed using putty.

Helmer Scientic i.Series® and Horizon Series™Refrigerator - Upright Operation Manual
360372/B 8
2.4 Chart Recorder (If Included)
Note
For complete information, refer to the Temperature Chart Recorder Operation and Service Manual provided with this unit.
The chart recorder has a back-up battery system enabling a period of continuous operation if power is lost. Battery life varies by
manufacturer as well as voltage level remaining. If full battery power is available, back-up power for the temperature chart recorder
is available for up to 14 hours.
Note
If chart recorder is operated on battery power, the battery should be replaced to ensure the back-up source has proper
charge.
Prior to use:
Place probe in bottle with primary monitor probe.
Set up and Operation
Access chart recorder by pressing and releasing (i.Series) or pulling door open (Horizon Series).
i.Series chart door Horizon Series chart door
Install battery.
Connect the leads to the battery to provide back-up power to the chart recorder.

Helmer Scientic i.Series® and Horizon Series™Refrigerator - Upright Operation Manual
360372/B 9
Install / Replace Chart Paper
Note
For accurate temperature reading, ensure the current time is aligned with the time line groove when the chart knob
is fully tightened.
Chart recorder stylus and time line groove
1. Press and hold C button. When stylus begins to move left, release button. The LED ashes.
2. When stylus stops moving, remove chart knob then move knob up and away.
3. Place chart paper on chart recorder.
4. Gently lift stylus and rotate paper so current time line corresponds to time line groove.
5. Hold chart paper in place while making sure the chart knob is fully tightened. (Failure to fully tighten the knob can result in paper
slipping and losing time.)
6. Press and hold C button. When stylus begins to move right, release button.
7. Conrm stylus is marking on paper and stops at the correct temperature.
8. Calibrate chart recorder to match primary temperature if needed and close recorder door.
Power Supply
The temperature chart recorder uses AC power when the system is operating. If AC power fails, the recorder continues to record
temperature with back-up power provided by the nine-volt battery.
♦The LED indicator glows green continually when main power is functioning and the battery is charged.
♦The LED indicator glows red continually when main power is functioning and the battery is either not installed or needs to be
changed.
♦ The LED indicator ashes red to indicate that the recorder is receiving power only from the back-up battery.
♦ The LED indicator ashes during chart paper change mode.

Helmer Scientic i.Series® and Horizon Series™Refrigerator - Upright Operation Manual
360372/B 10
3 i.Series®Operation
3.1 Initial Power-Up
1. Plug the power cord into a grounded outlet that meets the electrical requirements on the product specication label.
2. Turn theAC power switch ON.
3. Turn the Back-up battery switch ON.
Notes
• For models equipped with optional Access Control, the back-up battery is turned ON with a key switch.
• The Start screen is displayed when the i.C3is powered on. The i.C3will take approximately 2-5 minutes to boot up.
Start screen
The language screen is displayed when the i.C3is powered on. Use the Language screen to select the i.C3display language.
Language screens
Note
English is the default language.
If an alarm sounds, temporarily mute the alarm by touching the Mute button.
Home screen - alarm muted Mute icon
Note
Active alarms are displayed on the Home screen. If an alarm condition other than High Temperature occurs, refer to the
service manual for troubleshooting.
i.Series Operation
Otros manuales para i Series
6
Este manual sirve para los siguientes modelos
31
Tabla de contenidos
Otros manuales de Refrigerador de Helmer

Helmer
Helmer i.series Manual de usuario

Helmer
Helmer i.series Manual de usuario

Helmer
Helmer iBX020 Manual de usuario

Helmer
Helmer i.series Manual de usuario

Helmer
Helmer i Series Manual de usuario

Helmer
Helmer i.series Manual de usuario

Helmer
Helmer i.series Guía de instalación y uso

Helmer
Helmer iB111 (Version A) Manual de usuario

Helmer
Helmer i.series Manual de usuario

Helmer
Helmer iB105 Manual de usuario