15:Digital Setting
FLOOR:1 IND:1 When the floor number is blinking, set the floor number with the UP-
DOWN buttons till you come to the floor number you want to change.
Press the ENTER button and next you will see the digits blinking. Set
the value you like. When finished exit with the exit button. Or if you
want to set another stop/floor, press the enter button, when floor
number is blinking, repeat the steps.
10
Outputs that can be selected
7 Segment indicator -4, -3, -2, -1, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 ,11, 12, 13, 14, 15, 16
A, B, C, D, E, F, H, J, L, N, O, P
16:Display Output
Normal
Set the display output of the HD EKO-10 controller card and HD EKO
SERI card.
7 Segment output Normal output.
Gray code output Gray code output.
17:Max. Call Reg.
010
Set the maximum amount of calls that can be registrated from within
cabin. When this number is reached it stops registrating any calls from
within cabine.
01 - 10 Set the number of stops between the minimum and maximum.
18:Number of basement
000 Set the number of basement here.
If the elevator is down collective, the floors that are under the basement that is set, it will be up collective.
Note: Used in command types except for down collective.