Heat Controller B-VFH-1 Multi-Zone Wireless / Wired Remote Control
3
No. Name Function
1 Enter/Cancel Function selection and cancellation.
2▲jRunning temperature setting of the indoor unit, range: 60°F - 86°F (16°C - 30°C).
kTimer setting, range:0.5-24 hr.
6▼
3 Fan Setting of the high/middle/low/auto fan speed.
4 Mode Setting of the Cooling/Heating/Fan/Dry/Auto mode of the indoor unit.
5 Function Switchover among the functions of Turbo/Save/E-heater/Blow etc.
7 Timer Timer setting.
8 On/Off Turn on/off the indoor unit.
4+2 ▲+Mode
Press for 5s under off state of the unit to Enter/Cancel the Memory function (If memory is set, indoor
unit after power failure and then power recovery will resume the original setting state. If not, the
indoor unit is defaulted to be off after power recovery. Memory off is default).
3+6
Fan+▼ By pressing them at the same time under off state of the unit, will be displayed on the wired
remote controller for the cooling only unit, while will be displayed on the wired remote controller
for the cooling and heating unit.
Upon startup of the unit without malfunction or under off state of the unit,press them at the same
time for 5s to enter the lock state, in which case, any other buttons won’t respond the press. Repress
them for 5s to quit this state.
4+6 ▲+▼
4+6 Mode+▼
Under OFF state, the Celsius and Fahrenheit scales can be switched by
pressing “Mode” and “▼” for ve seconds.
Under OFF state, it is available to go to the commissioning status by pressing “Function” and “Timer”
for ve seconds, and let “00” displayed on the temperature display area by pressing “Mode”, then
adjust the options which are shown on the timer area by pressing “▲” and “▼”. There are four
options, as follows:
jIndoor ambient temperature is sensed by the return air temperature
sensor ( 01 displayed on the timer area).
kIndoor ambient temperature is sensed by the wired controller (02 displayed on the timer area).
lThe return air temperature sensor is selected under the cooling, dry, or fan mode; while the wired
controller temperature sensor is selected under the heating or auto mode. (03 is displayed on the
timer area).
mThe wired controller temperature sensor is selected under the cooling, dry, or fan mode; while
the return air temperature sensor is selected under the heating mode. (04 is displayed on the timer
display area).
5+7 Function+Timer
5+7 Function+Timer
Under OFF mode, go to the commissioning status by pressing “Function” and “Timer” for ve
seconds. Press “Mode” button to until “01” icon is shown at the temperature display area. The setting
status will be shown at timer area. Press “▲” and “▼” button to adjust and two options are available:
jThree low levels (01) ; kThree high levels (02).
Table 2