Hearth and Home Technologies PS35 Manual de usuario

July 28th, 2011
PELLET STOVE
SERVICE MANUAL
Shock and Smoke Hazard
• Turndownthermostat,letappliancecompletely
coolandexhaustblowermustbeoff.Nowyou
canunplugappliancebeforeservicing.
• Smokespillageintoroomcanoccurifappliance
isnotcoolbeforeunplugging.
• Riskofshockifappliancenotunpluggedbefore
servicingappliance.
CAUTION
• Installationanduseofanydamagedappliance.
• Modicationoftheappliance.
• Installation other than as instructed by Hearth & Home
Technologies.
• Installationand/oruseofanycomponentpartnotapproved
byHearth&HomeTechnologies.
• Operating appliance without fully assembling all
components.
• Operatingappliancewithoutlegsattached(ifsuppliedwith
unit).
• DoNOTOverre
Or any such action that may cause a re hazard.
WARNING
Hearth&HomeTechnologiesdisclaimsany
responsibilityfor,andthewarrantywillbe
voidedby,thefollowingactions:
FireRisk.
NOTE: Hearth&HomeTechnologies,manufacturerof
thisappliance,reservestherighttoalteritsproducts,
theirspecicationsand/orpricewithoutnotice.
Shockhazard.
• DoNOTremovegroundingprongfromplug.
• Plugdirectlyintoproperlygrounded3prong
receptacle.
• Unplugcordbeforedoinganychecksorrepairs.
•
DoNOTtouchwireswhileunitispluggedin.
CAUTION

ECO CHOICE PELLET STOVE SERVICE MANUAL
TABLE OF CONTENTS
SECTION PAGE
TROUBLE-SHOOTINGSYMPTOMS
OPERATIONFLOWCHART
FEEDMOTORTROUBLE-SHOOTING
IGNITERTROUBLE-SHOOTING
EXHAUSTBLOWERTROUBLE-SHOOTING
CONVECTIONBLOWERTROUBLE-SHOOTING
POWERSUPPLYTROUBLE-SHOOTING
THERMOSTATTROUBLESHOOTING
THERMOCOUPLETESTING
FIREPOT&EXHAUSTSYSTEMTROUBLE-SHOOTING
WIREDIAGRAM
GENERALSPECIFICATIONS
CHECK-OFFSHEET
CLEANING&MAINTENANCETIPS
3-5
6-9
10
11
12
13
14-15
16
17
18-20
21
22
23
24-25
PAGE2

ECO CHOICE PELLET STOVE SERVICE MANUAL
TROUBLE SHOOTING & REPAIR
A. PLUG IN STOVE -- NO RESPONSE
1)CHECKTHEPOWERSUPPLYFOR115VOLTS
2)CHECKTHEFUSEINTHEJUNCTIONBOX(7AMP)
3)CHECKSNAPDISC#3FORPOWER
4)CHECKCONTROLBOX
B. CALL LIGHT ON -- NO FIRE -- NO FUEL IN FIREPOT
1)CHECKHOPPERFORBRIDGINGOFPELLETS
2)PUSHRESETBUTTON&ADJUSTFEEDADJUSTMENTPLATE
3)CHECKTOMAKESURETHEFRONTDOORISCLOSED
4)CHECKVENTINGSYSTEMFOROBSTRUCTIONS
5)CHECKVACUUMSWITCHANDVACUUMHOSE
6)CHECKFEEDMOTOR
7)CHECKEXHAUSTBLOWER
8)CHECKHOPPERSWITCH
C. CALL LIGHT ON -- NO FIRE -- PARTIALLY BURNED FUEL IN POT
1)CHECKFIREPOTANDCLEAN
2)CHECKTHERMOCOUPLE
*GREENLIGHT-----2.7mV(+.5mV)
*REDLIGHT---------12.0mV(+1mV)
3)CHECKINITIALFEEDTIME(60SECONDS)
D. CALL LIGHT ON -- NO FIRE -- FUEL IN FIREPOT
1)CHECKFIREPOTFOR“CLINKER”MATERIAL
2)CLEANFIREPOT
3)CHECKIGNITER
4)CHECKCONTROLBOX
PAGE3
Shockhazard.
• DoNOTremovegroundingprongfromplug.
• Plugdirectlyintoproperlygrounded3prong
receptacle.
• Unplugcordbeforedoinganychecksorrepairs.
•
DoNOTtouchwireswhileunitispluggedin.
CAUTION

ECO CHOICE PELLET STOVE SERVICE MANUAL
E. SLOW OR SMOKEY START UP
1)CLEANFIREPOT
2)FEEDADJUSTMENTPLATEMAYBESETTOOHIGH
3)CHECKEXHAUSTBLOWERANDHEATEXCHANGER
TROUBLE SHOOTING & REPAIR
G. FEED SYSTEM FAILS TO START
1)CHECKFRONTDOORANDMAKESUREITISCLOSED
2)CHECKTOSEEIFCALLLIGHTISON
3)CHECKTHERMOSTAT,#2SNAPDISC,ANDHOPPERSWITCH
4)CHECKFEEDMOTORANDVACUUMSWITCH
5)CHECKEXHAUSTSYSTEMFOROBSTRUCTIONS
H. THERMOSTAT WILL NOT START UNIT
1)CHECKTHERMOSTATWIRESFORCONTINUITY
2)CHECKTHEHOPPERSWITCH
3)CHECKTHERESETBUTTON
4)CHECKFORPOWERTOTHESTOVE
5)CHECKCONTROLBOX
F. STOVE RUNS FOR 18 MINUTES -- THEN STOPS FEEDING FUEL
1)CHECKTHERMOCOUPLE
*GREENLIGHT(2.7mVDC)
*REDLIGHT(12.0mVDC)
2)ADJUSTFEEDADJUSTMENTPLATEFORLARGERFIRE
3)CHECKTHERMOCOUPLECOVER
*COVERNEEDSTOTOUCHTHEENDOFTHET-COUPLEWIRE
*COVERSHOULDEXTEND1”INTOFIREPOT
4)CHECKCONTROLBOX
PAGE4
Shockhazard.
• DoNOTremovegroundingprongfromplug.
• Plugdirectlyintoproperlygrounded3prong
receptacle.
• Unplugcordbeforedoinganychecksorrepairs.
•
DoNOTtouchwireswhileunitispluggedin.
CAUTION

ECO CHOICE PELLET STOVE SERVICE MANUAL
I. UNIT FAILS TO SHUT OFF
1)CHECKTHERMOSTATANDTHERMOSTATWIRE
2)CHECKTHEJUNCTIONBOX&WIREHARNESS
3)CHECKTHECONTROLBOX
TROUBLE SHOOTING & REPAIR
J. CONVECTION BLOWER KEEPS RUNNING OR FAILS TO START
1)CHECK#1SNAPDISC
2)CHECKCONVECTIONBLOWER
3)CHECKFORVOLTAGETOTHE#1SNAPDISC
K. STOVE CYCLES ON AND OFF -- THERMOSTAT ALWAYS ON
1)CHECKCONTROLBOX
2)CHECKVACUUMSWITCHORHOPPERSWITCH
3)CHECKWIRINGFORLOOSECONNECTIONS
L. LARGE FIRE, ASH BUILD UP & DIRTY GLASS
1)CHECKFIREPOT,MAYNEEDTOBECLEANED
2)CLEANEXHAUSTANDHEATEXCHANGERSYSTEM
3)ADJUSTFEEDADJUSTMENTPLATEINTHEHOPPER
4)CHECKCONTROLBOXFEEDTIMES
M. STOVE IGNITES -- GOES OUT -- CALL LIGHT STILL ON
“STOVEISINCONSISTANTINOPERATION“
1)INSPECTTHERMOCOUPLEANDITSPOSITIONOVERTHEPOT
2)CHECKTHEFEEDMOTOR
3)ADJUSTFEEDADJUSTMENTPLATEFORALARGERFIRE
4)CHECKTHEEXHAUSTANDHEATEXCHANGERSYSTEM
5)CHECKTHEVACUUMSWITCHORHOPPERSWITCH
PAGE5
Shockhazard.
• DoNOTremovegroundingprongfromplug.
• Plugdirectlyintoproperlygrounded3prong
receptacle.
• Unplugcordbeforedoinganychecksorrepairs.
•
DoNOTtouchwireswhileunitispluggedin.
CAUTION

ECO CHOICE PELLET STOVE SERVICE MANUAL
OPERATION FLOWCHART
FOLLOW THE PELLET STOVE OPERATION AND VERIFY THAT EACH COMPONENT IS COMING ON.
IF THAT COMPONENT IS NOT COMING ON, REFER TO THE TROUBLESHOOTING SECTION FOR THAT COMPONENT.
AFTER THAT PART HAS BEEN FIXED, PROCEED WITH THE OPERATION OF THE STOVE AND MAKE SURE THAT EACH OPERATION IS
TAKING PLACE.
THERMOSTAT
TURNS ON.
RED CALL LIGHT
ILLUMINATES
ON THE STOVE.
(START)
1
EXHAUST
BLOWER TURNS
ON.
2
IGNITER TURNS
ON.
3
VACUUM SWITCH
CLOSES.
4
ITEMS TO CHECK: POSSIBLE PROBLEMS OR FAILED COMPONENT
BOX 1: THERMOSTAT, THERMOSTAT WIRE, WIRE HARNESS, OR CONTROL BOX
BOX 2: EXHAUST BLOWER, CONTROL BOX, WIRE HARNESS
BOX 3: IGNITER, CONTROL BOX, WIRE HARNESS
BOX 4: VACUUM SWITCH, VACUUM HOSE, VENT OR HEAT EXCHANGER BLOCKAGE, DOOR SEAL
CALLLIGHT
PAGE6

ECO CHOICE PELLET STOVE SERVICE MANUAL
OPERATION FLOWCHART
FEED MOTOR
WILL FEED FOR
54 SECONDS AND
STOP.
5
PELLETS IGNITE
IN THE FIREPOT.
6
HEAT FROM FIRE
TURNS ON GREEN
THERMOCOUPLE
LIGHT IN THE
CONTROL BOX
(2.7mVDC) 7
FEED MOTOR
STARTS ITS
CYCLE MODE.
(EACH CYCLE IS 7
SECONDS)
8
HEAT FROM FIRE
TURNS ON RED
THERMOCOUPLE
LIGHT IN THE
CONTROL BOX
(12.1mVDC) 9
ITEMS TO CHECK: POSSIBLE PROBLEMS OR FAILED COMPONENT
BOX 5: #2 SNAP DISC, WIRE CONNECTIONS, FEED MOTOR, CONTROL BOX, HOPPER SWITCH
BOX 6: FIREPOT, FEED ADJUSTMENT PLATE, VENT PIPE BLOCKAGE
BOX 7: THERMOCOUPLE, THERMOCOUPLE CONNECTIONS, CONTROL BOX, WIRE HARNESS
BOX 8: CONTROL BOX, THERMOCOUPLE, FEED ADJUSTMENT PLATE
BOX 9: CONTROL BOX, THERMOCOUPLE, FEED ADJUSTMENT PLATE
FEED MOTOR “ON” TIMES
PS 35
LOW=0.9 SECONDS
MEDIUM=1.6 SECONDS
HIGH=2.2 SECONDS
PS 50
LOW=1.1 SECONDS
MED=1.9 SECONDS
HIGH=2.7 SECONDS
PAGE7

ECO CHOICE PELLET STOVE SERVICE MANUAL
(CONTINUED)
ROOM REACHES
TEMPERATURE.
13
CONVECTION
BLOWER TURNS
ON.
12
THERMOSTAT
TURNS OFF
14
HEAT FROM FIRE
CLOSES #1 SNAP
DISC.
11
ITEMS TO CHECK: POSSIBLE PROBLEMS OR FAILED COMPONENT
BOX 10: CONTROL BOX
BOX 11: #1 SNAP DISC, WIRE CONNECTIONS, WIRE HARNESS, CONVECTION BLOWER
BOX 12: CONVECTION BLOWER, WIRE CONNECTIONS
BOX 13: FEED ADJUSTMENT PLATE, PELLET FUEL, CONTROL BOX
BOX 14: THERMOSTAT, THERMOSTAT WIRE
IGNITER TURNS
OFF.
10
OPERATION FLOWCHART
PAGE8

ECO CHOICE PELLET STOVE SERVICE MANUAL
END OF CYCLE.
UNIT IS NOW
READY FOR
ANOTHER CALL
FOR HEAT.
(END)
RED CALL LIGHT
TURNS OFF.
15
FEED MOTOR
TURNS OFF.
16
EXHAUST
BLOWER STARTS
18 MINUTE
COUNTDOWN.
17
#1 SNAP DISC
COOLS OFF.
18
CONVECTION
BLOWER SHUTS
OFF.
19
OPERATION FLOWCHART
ITEMS TO CHECK: POSSIBLE PROBLEMS OR FAILED COMPONENT
BOX 15: THERMOSTAT, THERMOSTAT WIRE, WIRE HARNESS
BOX 16: CONTROL BOX
BOX 17: CONTROL BOX, WIRE HARNESS
BOX 18: #1 SNAP DISC
BOX 19: #1 SNAP DISC, WIRE HARNESS
CALLLIGHT
PAGE9

ECO CHOICE PELLET STOVE SERVICE MANUAL
FEED MOTOR TROUBLE-SHOOTING
1)TURNONTHERMOSTATCIRCUITANDMAKESURETHATTHECALLLIGHTISON
2)CHECKFORPOWERATTHEVACUUMSWITCH:
A.IFNOPOWERFROMREDWIRE-----CHECKCONTROLBOXORWIREHARNESS
B.POWERONREDFROMHARNESSBUTNOPOWERONREDGOINGTOHOPPERSWITCH-----CHECKVACUUMSWITCHOR
VENTSYSTEM
3)CHECKFORPOWERATTHEORANGEWIREONTHEHOPPERSWITCH
A.IFNOPOWERFROMORANGEWIRE----CHECKWIREHARNESSORHOPPERSWITCH
B.IFPOWERISPRESENT-----CHECK#2SNAPDISC
NOTE: REMEMBER THAT THE FEED CIRCUIT INITIAL FEED TIME IS 60 SECONDS. PUSH THE RESET
BUTTON BEFORE EACH TEST.
4)CHECKFORPOWERATTHEBLACKWIREFROM#2SNAPDISC:
A.IFNOPOWERFROMBLACKWIRE----CHECKWIREHARNESSORSNAPDISC
B.IFPOWERISPRESENT-----CHECKFEEDMOTOR
FEED MOTOR
VACUUM
SWITCH
JUNCTION BOX
FEED MOTOR CIRCUIT
WHITE
RED
WHITE WHITE
BLACK
RED
RED
WHITE
ORANGE
RED
BLACK
#2 SNAP DISC
HOPPER SWITCH
CAPACITOR
CALL LIGHT
PAGE10
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Estufa de pellets de Hearth and Home Technologies
Manuales populares de Estufa de pellets de otras marcas

Ferroli
Ferroli GEMMA Manual de usuario

pleasant hearth
pleasant hearth PH35PS Series Manual de usuario

Breckwell
Breckwell Tradition P24FS Manual de usuario

Quadra-Fire
Quadra-Fire CB1200M-MBK Manual de usuario

England's Stove Works
England's Stove Works 25-EP Manual de usuario

Avalon
Avalon Astoria Manual de usuario