Cautionary Reminder
Transport Spray Away Elite by the base
(bottom) – do not pick up Spray Away Elite
by the head or neck.
Do not transport Spray Away Elite when
Wa er Basin is full.
To prevent damage from freezing water,
take Spray Away Elite inside when the
temperature drops below 32°F.
Empty Wa er Basin when stored.
Use hose/tap water – distilled water will
not activate the low water sensor.
Dust, dirt or hard water can limit sensitivity
– keep Infrared Sensor clean by wiping
gently with a damp cloth.
Clean Solar Panel.
Avoid touching Solar Panel as it may get
hot.
A maximum sensitivity level is more prone
to have repeated/erroneous sprays.
To minimize false triggers, avoid pointing
Spray Away Elite at moving water, windy
areas and moving vehicles.
Spray Away Elite may frighten small birds.
CARRY FROM BOTTOM!
SOLAR PANEL MAY BE HOT!
MAY FRIGHTEN BIRDS!
DO NOT PICK UP BY HEAD OR NECK!

3
How It Work
Havahart® Spray Away Elite Sprinkler Repellent provides an innovative, humane way
to keep unwanted animals out of your yard and garden. Sensing animals of all sizes,
Spray Away Elite provides an environmentally-friendly and safe alternative to chemical
repellents and electric fences. Spray Away Elite uses an infrared sensor to detect the
animal, and then deploys a burst of water combined with unexpected noise and motion
to create a safe and effective deterrent.
Best of all, Spray Away Elite does not use an attached garden hose – making it portable
and easy to use! Instead of a hose, it utilizes a water basin that holds 3.5 gallons of
water and lasts for approximately 35 activations.
Spray Away Elite is powerful enough to protect up to 1000 square feet while detecting
motion 35 feet in front of the unit. Whether you have a deer or rabbit snacking on plants,
or a heron stealing fish from your pond, the versatile Spray Away Elite will condition
these critters to find lunch elsewhere!
35 feet

4
Component
Sprinkler Head
ON/OFF Swi ch
Wrench
Infrared
Sensor
Indica or Ligh s
Wa er Basin
Wa er Fill Area
Missing omething? Call us at 1.855.542.8242!
Solar Panel
Owner’s
Manual
Sensi ivi y Knob

5
A embly Guide
Low water Low battery low battery/sensing
Low water &
INDICATOR LIGHTS GUIDE
Do Not be Alarmed if Indicator Lights Flash
3.
Attach the prinkler Head
- Attach the Sprinkler Head by hand to the top
of the Solar Panel.
- Using the Wrench supplied, fully tighten
the Sprinkler Head by turning the Wrench
clockwise until it is firmly secured.
Note: Wrench will slip off sprinkler head when fully tightened. You will not be able to over-tighten sprinkler
head.
Charge pray Away Elite
- Place outside in full sun – do not fill with water.
- Turn Spray Away Elite ON and turn Sensi ivi y Knob
to the lowest setting to ensure the battery is not
drained while charging.
- Charge for 5 hours.
Note: Spray Away Elite can charge for more
than 5 hours – battery will not overcharge.
* Do not fill the Wa er Basin with water during initial charge to ensure the unit fully charges.
* To prevent damage from freezing water, take Spray Away Elite inside when the temperature drops below 32°F.
1.
2.

6
Placement Guide
Find the Ideal Location
Place Spray Away Elite in area in which animals will cross the Detection Range.
1.
Determine the Best Position
Place the unit so that the Solar Panel is level to the ground, and the Infrared Sensor is
facing the area to be protected.
2.
35 feet
50 feet
Infrared Sensor
Solar Panel
35 feet
3
Detection Range
Area to Protect

Testing the ensitivity
- Make sure you wait 30 seconds before moving in front of the sensor.*
- Start outside your desired coverage area and walk across path in front of Spray Away
Elite.
- Spray Away Elite’s Indica or Ligh s will illuminate for 3 seconds when it senses you.
Repeat this process until you are satisfied with Spray Away Elite’s coverage area.
Note: Spray Away Elite will reset for 8 seconds between activations and will not detect.
* If you move in front of the Infrared Sensor immediately after you turn Spray Away Elite on, start-up will be delayed.
2.
* Some small animals may not be seen
at this distance
7
Sen itivity Guide
INDICATOR LIGHTS FLASH HEN SENSING
DETERMINE COVERAGE AREA
SUGGESTED SETTINGS CHART SENSITIVITY KNOB
Animal Size 10 ft. 20 ft. 30 ft.
Small 6–7 7–9*
Medium 3–4 5–6 7–9
Large 2–3 4–5 6–9
etting the ensitivity
- Using the Suggested Settings Chart, adjust the Sensi ivi y Knob accordingly.
1.

Position tem Tabs to Adjust prinkler Travel
1.
8
Adju ting Water Coverage
Metal
Wire
Clip
Stem
Tabs Wide tabs produce
wide arc
Narrow tabs produce
narrow arc
- Set the sprinkler’s spray pattern to direct the water towards the desired
protection area.
Adjust the Water pray
2.
Minimum
Maximum Min
Clockwise increases
spray distance
Counter-clockwise reduces
spray distance
- Turn the unit OFF, then fill the Wa er Basin with tap/hose water.
- Fill Wa er Basin to the top of the Wa er Fill Area. Spray Away
Elite holds approximately 3.5 gallons of water. Do not feed hose
into unit.
- Stand behind the Infrared Sensor and turn the unit ON.
- Wave your hand in front of the Infrared Sensor to activate
Spray Away Elite and ensure the arc and distance fit your needs.
Note: To empty, tilt unit slightly and drain water from Wa er Basin.
One full Wa er Basin will last for approximately 35 sprays.
tart Repelling!
3.

Problem olutions Illustration
pray Away Elite
does not ‘see’
animals
Re-aim Spray Away Elite and
clean the Infrared Sensor with a
soft damp cloth.
pray Away Elite
leaks water
through its
prinkler Head
Debris is lodged in the Sprinkler
Head – remove Sprinkler Head
and run under water to dislodge
the debris.
Unit is activating
when no animal
is present
Spray Away Elite is sensing
movement. Re-test the sensing
area as explained in the
instructions on page 7.
Low Water
Indicator Light
Turn unit OFF, then fill the basin
with hose/tap water. Turn unit
back ON.
Low Battery
Indicator Light
Place in full sun for 2-3 hours to
recharge – make sure to turn unit
ON and Sensi ivi y Knob down
while charging. May take up to
24 hours+ in overcast conditions.
Note: Make sure Solar Panel is free of
debris. Wipe Solar Panel with damp cloth
to clean.
Low Water & Low
Battery Indicator
Lights
Turn unit ON and Sensi ivi y Knob
down – recharge in full sun for 2-3
hours. Repeat Placement and
Setting the Sensitivity instructions
on pages 6-7.
9
Trouble hooting
If you encounter any problems with pray Away Elite, please call us at 1.855.542.8242.
yg
Tabla de contenidos
Otros manuales de Control de plagas de Havahart
Manuales populares de Control de plagas de otras marcas

BRC
BRC FLYinBOX 20 Manual de usuario

ECOstyle
ECOstyle Cat & Dog free 200 m2 Manual de usuario

Bell LABORATORIES
Bell LABORATORIES PULSE MOUSE IQ Manual de usuario

Gimenez Ganga
Gimenez Ganga Saxun 27 Vertical Manual de usuario

Silverline
Silverline gardenSystem Cat & Dog Free 200 Manual de usuario

Segula
Segula 50520 Manual de usuario