H1062,H1072,&H1082AUGERASSEMBLYMANUAL
Read&understandallinstructionspertainingtothisaugerpriortouse!

HarvestInternationalH10XXAssemblyManual Page2of34
Safety Alert
Watch for this ALERT Symbol. It identifies potential hazards to Personal SAFETY and
your HEALTH. It points out Safety precautions.
This SAFETY symbol means:
ATTENTION:
BE ALERT
Why is SAFETY important to you?
THREE BIG REASONS:
*ACCIDENTS DISABLE AND KILL
*ACCIDENTS COST
*ACCIDENTS CAN BE AVOIDED
Failure to read this Auger manual before operation of the Auger is a misuse of the
equipment and a needless risk to your HEALTH and SAFETY. Your life and limbs are
worth keeping. Use this equipment with care.
Symbol
Signal Words:
DANGER, WARNING, CAUTION
The appropriate signal word for each message has been selected using the following
guidelines below the Alert Symbol.
BE ALERT!
D
D
DA
A
AN
N
NG
G
GE
E
ER
R
R–Indicates an imminently hazardous situation that, if not avoided, will result
in death or serious injury. This signal word is to be limited to the most extreme situations,
typically for machine components that, for functional purposes, cannot be guarded.
W
W
WA
A
AR
R
RN
N
NI
I
IN
N
NG
G
G–Indicates a potentially hazardous situation that, if not avoided, could result
in death or serious injury, and includes hazards that are exposed when guards are
removed. It may also be used to alert against unsafe practices.
C
C
CA
A
AU
U
UT
T
TI
I
IO
O
ON
N
N–Indicates a potentially hazardous situation that, if not avoided, may result
in minor or moderate injury. It may also be used to alert against unsafe practices.

Page3of34
Harvestby MeridianH10XXAssemblyManual
Step 1
Tube Identification
1st Tube H1062, H1072, & H1082
2nd Tube H1062, H1072, & H1082
3rd Tube, Discharge H1062
3rd Tube, H1072 & H1082
4th Tube, Discharge H1072
4th Tube, Discharge H1082

Page4of34
Harvestby MeridianH10XXAssemblyManual
Step 2(Tube & Flighting Assembly)
Place tubes on assembly stands as shown. Place stands 12” or less from the end of the tube. Placing stands
further than 12” from end of the tube may cause damage to the tubes.
Step 3
Slide the flighting together from the 1st & 2nd tube. Connect the flighting using (2) 1/2" x 2-1/2” hex bolts and
top lock nuts. Align flighting as shown to make contineous. After connecting the flighting, slide the 1st & 2nd
tube together putting in the top 2 & bottom (2) 1/2" x 1-1/2” flange bolts & nuts. If assembling an H1082, snug
up the top bolts as they will need to be removed in step 5. If assembling H1082, after completeing Step 3 please
skip to Step 5.
Step 4
Place the left (10192) & right (10193) bolt on cable truss mount brackets onto the tubes & using (4)
1/2" x 1-1/2” flange bolts & nuts. (Note: The left bracket will have a small notch cut into the top of it) Tighten
all 8 bolts around tube flange. Skip to Step 6.
Fig. 2.1
Fig. 3.1
Fig. 4.1

Page5of34
Harvestby MeridianH10XXAssemblyManual
Step 5 (H1082 Only)
Place the left (10192), right (10193) & two of the upper (10256) bolt on cable truss mount brackets onto the
tubes & using (4) 1/2" x 1-1/2” flange bolts & nuts. The top 2 bolts will need to be removed to attach the 2
upper truss mount brackets. (Note: The left bracket will have a small notch cut into the top of it) Tighten all 8
bolts around tube flange.
Step 6
Place the 3rd tube in front of the 2nd tube and connect the flighitng as shown in Step 3. After the flighting is
connected and secure, slide the 2nd & 3rd tube together as shown. Mount the cable attachment brackets (10171)
to the left and right side fo the flange on the 2nd tube. Tighten the tubes and brackets together using (8)
1/2" x 1-1/2” flange bolts & nuts. After the 8 bolts are tight, attached the 3/8” quicklink to each bracket as
shown. Tighten both quicklinks. If assembeling an H1062 please skip to Step 8.
Fig. 5.1
Fig. 6.1

Page6of34
Harvestby Meridian H10XXAssemblyManual
Step 7 (H1072 & H1082 Only)
Place the 4rd tube in front of the 3nd tube and connect the flighitng as shown in Step 3. After the flighting is
connected and secure, slide the 3rd & 4th tube together as shown. Mount the cable attachment brackets (10171)
to the left and right side fo the flange on the 3nd tube. Tighten the tubes and brackets together using (8)
1/2" x 1-1/2” flange bolts & nuts. After the 8 bolts are tight, attached the 3/8” quicklink to each bracket as
shown. Tighten both quicklinks.
Step 8 (Discharge Head Assembly)
All tubes & flighting should now be assembled together. Now the discharge head should be attached. First
align the 5 studs on the flighting with the 5 holes in the discharge head. Fasten the discharge head to the
flighting using (5) 1/2" lock washers & (5) 1/2" lug nuts. Thread lug nuts on flat side against the lock washers.
Tighten the 5 lug nuts. Next, fasten the discharge head to the tube using (2) 1/2" x 1-1/2” flange bolts & nuts &
(6) 1/2" x 1-1/2” hex bolts & flange nuts. The flange bolts are used on the top 2 holes of the discharge head as
shown. If assembling a H1072 or H1082 the cable attachment brackets (10171) & the 3/8” quick links will
need to be mounted on both the left and right side of the tube as shown in Step 6 & 7. Tighten all 8 bolts
mounting the discharge head to the tube. Tie red flag supplied in the kit to the discharge head.
Fig. 7.1
Fig. 8.1

Page7of34
Harvestby MeridianH10XXAssemblyManual
Step 9 (Cable Mount & Truss Assembly)
In Step 9 the lower cable mount brackets will be installed. On the 1st tube bolt cable mount brackets (30976) to
the left & right side of the hopper arm bracket as shown. These will be fastened using (2) 5/8” x 1-1/2” flange
bolts & nuts. Be sure to angle the cable mount bracket slightly upwards as shown in figure 9.1.
Step 10
Next the cable truss uprights and cross brackets will be assembled on the 2nd & 3rd tubes. Start by placing the 2
upright truss brackets (10163) on the tube and fastening with a total of (12) 3/8” x 1” carriage bolts & flange
nuts. Leave these a little loose for ease of assembling the cross member. Assemble the cross member (10174)
using a total of (6) 3/8” x 1” carriage bolts & flange nuts as shown. After all carriage bolts are tigtenen, place
the 3/8” cable clamps on the out side of the trusses as shown. Thread nuts on by hand but do not tighten. If
assembling an H1082 cable clamps will also have to be added on the inside holes on the upper and middle
trusses.
Fig. 9.1
Fig. 10.1 Fig. 10.2

Page8of34
HarvestIby Meridian H10XXAssemblyManual
Step 11 (Infeed Housing Assembly)
Loosen bolts and remove both access panels. Using a lifting strap, lift and slide the infeed housing over the
bottom flighting on the 1st tube. Secure the infeed housing to the first tube using (6) 1/2" x 1-1/2” flange bolts
and nuts & (2) 1/2" x 1/1-2” hex bolts & flange nuts. The (2) 1/2" x 1-1/2” hex bolts shoule be used on the
bottom holes and orientated as shown in fig. 11.4.
Fig. 11.1 Fig. 11.2
Fig. 11.3 Fig. 11.4

Page9of34
Harvestby Meridian H10XXAssemblyManual
Step 12
Next, locate the gearbox mounted inside of the infeed housing. Remove the 2 top plugs in the gearbox &
replace the top one with the grease zerk & the bottom one with the breather provided.
Step 13
Next, slide the 4 botl 1-1/4” cast flange bearing over the shaft making sure the grease zerk is located on the
same side as the idler sprocket. (If the shaft has surface rust, clean first with an emry cloth) Secure the 4 bolt
bearing to the infeed housing using (4) 1/2" x 1-1/2” carriage bolts & flange nuts as shown. When completed
use a punch to rotate the shaft so the keyway is in an easy to access position.
Fig. 12.1
Fig. 13.1

Page10of34
Harvestby MeridianH10XXAssemblyManual
Step 14
Next, insert (2) 1/4" x 1” square keys into the top & bottom shaft. Slide the 18 tooth sprocket onto the top shaft
& the 20 tooth sprocket onto the bottom shaft as shown in fig. 14.1. Use a measuring tape & measure the
distance from the center of each sprocket to the infeed housing. Once sprockets are aligned, apply lock-tite to
set screws & tighten.
Step 15
Locate the #60 chain, #60 half link, & #60 connector link. Attach the half link to the chain on one end & place
the chain around the sprockets as shown in fig. 15.1. Secure chain with connector link. When connector link is
installed & the loop has been completed, push the idler sprocket in the chain to achieve good tension. When
proper tension is achieved tighten the idler sprocket. Now grease top & bottom bearings with multi-lith grease.
Fig. 14.1
Fig. 15.1
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Otros manuales de Herramientas de HARVEST