Hamilton XE Guía de inicio rápido

XE VALIDATOR
Operational Manual
Document #101-0079 1 11/30/17

Document #101-0079 2 11/30/17
TABLE OF CONTENTS
I. INTRODUCTION............................................................................................................................ 4
II. SWITCH SETTINGS....................................................................................................................... 5
III. ELECTRICAL CONNECTIONS....................................................................................................... 7
IV. TESTING...................................................................................................................................... 9
V. MAINTENANCE............................................................................................................................. 10
• Monthly (depending on use).................................................................................................... 10
• Yearly...................................................................................................................................... 10
• XE Validator Calibrations.......................................................................................................... 11
To calibrate the optics.......................................................................................................... 11
To calibrate the side scans................................................................................................... 11
VI. PARTS......................................................................................................................................... 12
VII. ERROR CODES .......................................................................................................................... 13
• Troubleshooting ..................................................................................................................... 14
APPENDIX A ................................................................................................................................... 20
• XE Validator Dimensions ......................................................................................................... 20

Document #101-0079 3 11/30/17
This manual will enable the operator to complete basic maintenance, identify error codes, and perform basic
troubleshooting.
A diagram of the validator dimensions is provided to assist operators in customizing the validator to individual
needs.
There are no user serviceable parts inside the validator. Further technical assistance can be obtained by
calling (800) 837-5561 or (419) 867-4858.
When calling for service, it is important to have the model and serial number readily available. Please take
the time to record this number in the space provided.
VALIDATOR MODEL & SERIAL #_________________________________________________
ABOUT THIS MANUAL

Document #101-0079 4 11/30/17
The XE VALIDATOR is an optical reading bill acceptor capable of validating one, five, ten or twenty dollar
bills. The XE can also accept the patented Hamilton paper Tokenotes®.
NOTE: Tokenotes®can be interchanged between the HV-X, XE and
STA Validators, but CANNOT be interchanged with previous validators.
Please include the model and serial number of the validator when ordering Tokenotes®.
FEATURES OF THE XE INCLUDE:
• Bill acceptance in both directions.
• Optical reading of bills.
• Tokenote®acceptance.
• Self-diagnostics.
• The ability to clear jammed bills.
• Operates with a separating stacker in certain changers
An upgradeable EPROM allows the software to be updated if new software becomes available.
I. INTRODUCTION

Document #101-0079 5 11/30/17
DIP SWITCH SETTINGS
Switch # OFF ON
1 Normal Operating Mode Diagnostic Mode
2 Accept Tokenotes®Reject Tokenotes®
3 Controller Runs Stacker Validator Runs Stacker
4 Not Using Dual Stacker Dual Stacker Being Used
5 Accepts in Both Directions Black Seal First
6 For HOPPER type machines
# of $1 RELAY pulses - 1 for $1
# of $5 RELAY pulses - 1 for $5
2 for $10
4 for $20
For TUBE type machines # of
$1 RELAY pulses.
1 pulse per dollar.
7 Accept $1 Reject $1
8 Accept $5 Reject $5
9 Accept $10 Reject $10
10 Accept $20 Reject $20
When programming Tokenotes®with the XE, all switches need to be set to the “ON” position. The switches
should be turned “ON” from BOTTOM to TOP, starting with switch #10.
When programming is complete, the switches should be turned “OFF” from TOP to BOTTOM, starting with
switch #1. This will prevent accidental entry into any diagnostic modes. It is possible to get error codes and
total reject by entering certain diagnostic modes. Cycling power will clear this diagnostic mode.
Switch #1: Switch #1 should ALWAYS be in the OFF position. The validator will not function properly
otherwise.
Switch #2: Switch #2 should be in the ON position unless the new Hamilton Tokenotes®are being
used. If they are being used, this switch should be moved to the OFF position.
When the #2 switch is ON, the validator rejects Tokenotes®already programmed in.
Switch #3: Switch #3 selects the source of stacker control signals when operating in pulse
communications mode. In serial communications mode, this switch is ignored. In nearly
all situations, this switch should be set to off.
Switch #4: Switch #4 should be in the OFF position unless the Hamilton Dual Stacker is being
used.
II. SWITCH SETTINGS

Document #101-0079 6 11/30/17
Switch #5: Switch #5 selects which direction the validator will accept an inserted bill. If this switch
is OFF, the validator will accept bills face up in either direction. If this switch is ON, the
validator will only accept bills face up and the end with the black seal inserted first.
Switch #6: Switch #6 selects how the validator signals the dispensing equipment after accepting a
bill. If this switch is OFF, the validator will activate the $1 Relay once for an accepted $1
bill, the $5 Relay once for an accepted $5 bill, the $5 Relay twice for an accepted $10
bill, and the $5 Relay four times for an accepted $20 bill.
If switch #6 is ON, the Validator will activate the $1 Relay once for an accepted $1 bill,
the $1 Relay five times for an accepted $5 bill, the $1 Relay ten times for an accepted
$10 bill, and the $1 relay twenty times for an accepted $20 bill.
SWITCH #6 DOES NOT WORK WITH TUBE TYPE CHANGERS.
Switch #7: Switch #7 selects whether the validator will accept or reject $1 bills. If the switch is in
the OFF position, the validator will accept $1 bills. If the switch is ON, the validator will
reject $1 bills.
Switch #8: Switch #8 selects whether the validator will accept or reject $5 bills. If the switch is in
the OFF position, the validator will accept $5 bills. If the switch is ON, the validator will
reject all $5 bills.
Switch #9: Switch #9 selects whether the Validator will accept or reject $10 bills. If the switch is in
the OFF position, the validator will accept $10 bills. If the switch is ON, the validator will
reject all $10 bills.
Switch #10: Switch #10 selects whether the Validator will accept or reject $20 bills. If the switch is
in the OFF position, the validator will accept $20 bills. If the switch is ON, the validator
will reject all $20 bills.
II. SWITCH SETTINGS

Document #101-0079 7 11/30/17
The electrical connections are made via a 9-pin connector located on the rear panel of the unit. The following
diagram and chart have been included for custom installation.
9-PIN CONNECTOR
EXTERNAL VIEW
321
654
987
WIRE VIEW
PIN # COLOR NAME
1 Blue Enable
2 White 120VAC Neutral
3 Brown Vend Common
4 N/A N/A
5 N/A N/A
6 Green Ground
7 White/Blue $1 Vend Contact Closure
8 White/Brown $5 Vend Contact Closure
9 Black 120VAC Hot
III. ELECTRICAL CONNECTIONS

Document #101-0079 8 11/30/17
When used in serial communications mode, serial data and stacker control signals are found on the 9-pin
connector of the display board. The following diagram and chart defines the available signals.
PIN # COLOR NAME
1 DIAG_TXD
2 Brown COM
3 DIAG_RXD
4 V5.0
5 Pink SM BUS _+
6 Lt Blue SM BUS_+
7 Yellow HOME
8 Black DOWN
9 Blue STK_DC
PIN 1
Diagnostic Header Pin 1 Location
with Smart Display Board
III. ELECTRICAL CONNECTIONS

Document #101-0079 9 11/30/17
IV. TESTING
After installation, a short test may be performed to verify correct installation.
For testing, be sure switch #1 is OFF. Be sure to test with a quantity of bills.
TEST DESIRED RESULT
Turn on unit Decimal point flashing
Insert bill Payout proper change for each bill type
Should this unit fail to operate accordingly, check for an error code and refer to the Troubleshooting
section of this manual.

Document #101-0079 10 11/30/17
MONTHLY - Depending on use
1. The platen assembly should be opened and cleaned regularly
2. To open the platen assembly:
• Unplug the changer
• Disconnect the 9-pin plug
• Remove the validator from the holder
• Loosen the 2 thumbscrews on both sides of the validator
• Carefully lift to open from the bill insert end of the validator
3. Clean rollers, heads, belts, and sensors with cotton swabs and rubbing alcohol
4. Close the platen assembly and re-tighten the LATCH STUDS. Loose LATCH STUDS may cause false error
codes.
YEARLY
The XE Validator should be serviced annually to maintain maximum performance.
THIS WORK SHOULD ONLY BE DONE BY A TRAINED TECHNICIAN.
V. MAINTENANCE
Tabla de contenidos
Otros manuales de Validador de billetes de Hamilton
Manuales populares de Validador de billetes de otras marcas

Alberici
Alberici BILLYONE UN1 Manual de usuario

Kolibri
Kolibri Bishop Manual de usuario

Royal Sovereign
Royal Sovereign RCD-2000 Manual de usuario

Innovative Technology
Innovative Technology BV100 Manual de usuario

Innovative Technology
Innovative Technology NV4 Manual de usuario

Innovative
Innovative NV200 Manual de usuario