Haltian thingsee AIR Manual

User and Installation Guide
AIR
v.21.04

Welcome to use Thingsee
Congratulations on choosing Haltian Thingsee as your IoT solution. We
at Haltian want to make IoT easy and accessible for everyone, so we
have created a solution platform that is easy to use, scalable and
secure. I hope our solution will help you achieve your business
goals!
Pasi Leipälä
CEO, Haltian Oy
Thingsee AIR
Thingsee AIR is a state of the art, battery powered wireless IoT sensor
for your indoor air quality monitoring. Together with CO₂ , TVOC,
temperature, barometric pressure, humidity sensors and ambient light
sensor, it’s a perfect device to provide an extensive overlook to both
present air quality data and the data history.
Thingsee AIR is part of Haltian Thingsee IoT solution and product
family.

Using Thingsee AIR sensor
Sales package content
Thingsee AIR detects carbon dioxide (CO₂), total volatility of organic
compounds (TVOC), temperature, humidity, barometric pressure and
ambient light. The product is installed on the wall in the space
where air quality is measured.
Thingsee AIR is a perfect tool to measure indoor air quality (IAQ) in
buildings and structures, especially as it relates to the health and
comfort of the building’s occupants. The sensor ensures real-time air
quality data for, e.g. adequate ventilation in the premises.
Thingsee AIR uses event-based messaging where measurement is done
every 5 minutes. In case there is a change to the previous
measurement, the measured value will be reported immediately. In
case the measurement value remains at the same level, it’s reported
every 1 hour.
• Thingsee AIR sensor
• 2 x AA batteries
• Screw and anchor to attach the product to the wall
• 1 x Opening Key

Note before installation
Please make sure the Thingsee GATEWAY is installed before you install
the sensor.
To ensure strong enough signal strength for data delivery, keep the
maximum distance between installed sensors under 20 m.
If the distance between a measuring sensor and the gateway is > 20 m
or if the sensors are separated by a fire door or other thick building
materials, use extra sensors as routers to ensure adequate signal
strength.
General installation instructions
The sensor is for indoor use only.
The environment humidity should be <85 % RH at all time.
The usage temperature range is +5 ºC to +50 ºC, non-condensing
environments only.
Please note that the correct TVOC and CO₂ data are available only aer
the sensor device has conducted baseline calibration for the
environment.
• TVOC sensor conducts baseline calibration for the TVOC levels and
valid data is available aer 24h of continuous use.
• Accurate CO₂ baseline level is set by auto-calibration during the first 8
days of usage. The auto-calibration is based on the outdoor CO₂ level.
CO₂ level in normal air pressure is 400 ppm.
Note: Thingsee AIR requires ‘free of people’ moments in the space,
when the indoor air is fully changed, to set the correct 400 ppm
baseline. This is why places such as schools and oices are good places
to use the sensor, as the baseline can be set during the night.

Things to avoid in installation
Avoid installing Thingsee products near the following:
Direct sun light
Nearby heating or cooling devices and/or vents
Thick concrete structures or thick fire doors
Electrical transformers or thick electrical wires
Escalators
Nearby halogen lamps, fluorescent lamps or
similar lamps with hot surface
Nearby radio equipment like WiFi routers or any
other similar high power RF transmitters
Avoid installing the sensor in close proximity to a
spot where there’s people presence constantly,
such as right next to workstations.

Installation
Open the box and follow the instructions of this user and installation
guide. Take the product from the box and open it with the opening key.
Select a place where to install Thingsee AIR (see ‘Things to avoid in
installation’ before). The recommended height on the wall is between
1,4 m – 1,8 m.
Bend the
key to the
direction
shown
Place the
opening
key to the
hole on the
side of the
sensor
Wall
When holding the sensor in hand: Place the opening key in the hole on
the side of the sensor and twist to open.
When the sensor is on the installed surface:
A-cover B-cover
A-cover
Opening Key

Place the batteries inside the A-cover.
Batteries
A-cover
Take the B-cover and place it on the wall on the decided location.
Screw the B-cover to the wall (use anchor with concrete wall or
gypsum board).

Attach the A-cover to the B-cover attached to the wall. (Make sure the
Thingsee logo is the right way).
Note: Make sure the sensor is installed max. 20 meters from the next sensor or
gateway. This is to ensure full coverage mesh network between the sensors and
the gateway.
A-cover
B-cover
To identify the sensor, read the QR code on the side of the A-cover
with a QR code reader or Thingsee installation application on your
mobile device.
Identifying the device is not necessary, but it will help you keep track of
your IoT installation and help Haltian support to solve possible issues.
DEVICE
DEVICE EVENTS TOPOLOGY
DEVICE
DEVICE EVENTS TOPOLOGY
AIR
BIN VERSION:
3.4.37.0
SW VERSION:
2018.07.02.2_ts_pinsp34
BATT LEVEL: 100%
DESCRIPTION: Room1
TUID: TSPR042O02500875
INFO
AIR
16/11/2018 09:15:57
16/11/2018 09:14:57
16/11/2018 09:13:57
16/11/2018 09:12:57
16/11/2018 09:11:57
QR code

Detection capability
• CO₂ measurement range 400 – 5 000 ppm; extended range up to
10 000 ppm.
Accuracy ±3 % (In extended range ±10 %).
• TVOC measurement range 0 – 60000 ppb.
Resolution 1 ppb at range 0 ppb - 2008 ppb, 6 ppb at range
2008 ppb – 11110 ppb, 32 ppb at range 11110 ppb - 60000 ppb.
• Temperature -40 ºC to + 85 ºC.
Please note recommended operation temperature +5 ºC to +50 ºC.
Accuracy ±0,2 ºC.
• Relative humidity can be measured between 0 -100% RH.
Accuracy ±2 %.
• Barometric pressure can be measured between 300 - 1200 hPa.
Absolute accuracy is ±1 hPa.
Pressure sensor precision is ±0.002 hPa in high precision mode.
• Ambient light sensing between 0 - 100k nW/cm2.
Light level measurement not calibrated. Only for indicative
purposes.
TVOC: 320 ppb
Air Pressure: 1013,25 hPa
Ambient Light: 922 lux
Air Quality Humidity: 67,4 %
Temperature: 21,1 ºC
CO2: 782 ppm

CO₂ values reference
Examples of reference values
TVOC values reference
250-400 ppm
Level
Normal background concentration in outdoor ambient air
Recommendation
Concentrations typical of occupied indoor spaces with
good air exchange
Complaints of drowsiness and poor air
Headaches, sleepiness and stagnant, stale, stuy air.
Poor concentration, loss of attention, increased heart rate
and slight nausea may also be present
Workplace exposure limit (as 8-hour TWA) in
most jurisdictions
Dangerous level: Exposure may lead to
serious oxygen deprivation
400-1000 ppm
1000-2000 ppm
2000-5000 ppm
> 5000 ppm
> 40,000 ppm
5
Unhealthy
Level Hygienic Rating Recommendation
Use only if unavoidable -
- intense ventilation necessary Hours 2200 - 5500
660 - 2200
220 - 660
65 - 220
0 - 65
< 1 month
< 12 months
no limit
no limit
Exposure Limit TVOC (ppb)
Intensified ventilation -
- airing necessary
Search for sources
Intensified ventilation -
- airing recommended
Search for sources
Ventilation - airing
recommended
Target value
Situation not
acceptable
Major
objections
Some
objections
No relevant
objections
No objections
4
Poor
3
Moderate
2
Good
1
Excellent
Otros manuales para thingsee AIR