Haier CA0065EANR Manual de usuario

1
Service Manual
INVERTER MODULAR CHILLER
SYJS-11-2018 REVA Edition: 2018-11

1
CONTENTS
1. Nomenclature ........................................................................................................................................................ 1
2. Feature .................................................................................................................................................................. 1
2.1 Product feature.................................................................................................................................................... 1
2.2 High Efciency..................................................................................................................................................... 2
2.3 Easy Installation .................................................................................................................................................. 2
2.4 Comfort................................................................................................................................................................ 4
2.5 High Reliability..................................................................................................................................................... 5
3. Specication .......................................................................................................................................................... 7
4. Dimension.............................................................................................................................................................. 9
5. Refrigerant system diagram ................................................................................................................................ 10
6. Installation ........................................................................................................................................................... 11
6.1 Symbol precautions........................................................................................................................................... 11
6.2 Installation ......................................................................................................................................................... 13
6.3 Water pipe connection....................................................................................................................................... 16
6.4 Electrical Connection Precautions..................................................................................................................... 21
6.5 Debugging and running ..................................................................................................................................... 26
6.6 Regular inspection of the project....................................................................................................................... 27
6.7 Maintenance...................................................................................................................................................... 28
7. Controller Operation Instruction........................................................................................................................... 29
8. Wiring diagram .................................................................................................................................................... 40
9. PCB photo and address code setting.................................................................................................................. 41
10. Fault code.......................................................................................................................................................... 42
11. Trouble shooting ................................................................................................................................................ 44
12. Unit operating range and service condition ....................................................................................................... 46
12.1 Unit operating range........................................................................................................................................ 46
12.2 Unit operating conditions................................................................................................................................. 46
13. Technical parameters ........................................................................................................................................ 47
14. Sensor charistic................................................................................................................................................. 48
15. Appendixi table for manual updated information ............................................................................................... 49

1
1. Nomenclature
2. Feature
2.1 Product feature
Code Explanation for chiller
1 2 3 4 5 6 7 8 9 10
Chiller
system Compressor type
Capacity
(for
Centrifugal
chiller: Rt;
other: kW)
Product type Unit
character
Suitable
voltage Design number
C
Centrifugal chiller C 1 0 6 9
Heat
pump
R22 A Air
cooled A100-115V,
60Hz 1Fixed
frequency A-G
Screw
chiller
Air
cooled
I
0 2 3 7 R407C B Water
cooled W220-240V,
50Hz 2Inverter H-Q
Water
cooled 0 0 1 2 R132 C Earth
source
E
115-220V,
50/60Hz 3DC
inverter R-Z
Earth
source R134A D 220-220V,
60Hz 4
Air-cooled
module chiller A R410A E 110V, 50-
60Hz 5
Light
chiller
Split-
packaged H
Cooling
only
R22 M 220V, 50-
60Hz 6
Single-
packaged R R407C N 127V, 60Hz 7
Water-cooled cabinet
chiller W R132 O 240V, 50Hz 8
Hydronic
system
Cassatte B R134A P 110-220V,
50/60Hz 9
Duct D R410A Q 330V, 50Hz A
Cabinet P 400V, 50Hz B
Wall
mounted S3300V, 50Hz C
6600V, 50Hz D
380-400V,
50Hz N
415V, 50Hz M
‘Y’ shape appearance
‘Y’ shape design is more fasion and increases the heat exchanger area.

2
2.2 High Efciency
2.3 Easy Installation
EC Fans
Driver Module
Condenser Coils
DC Inverter Rotary
1Compressor Motor
The unit adopts full DC inverter rotary
compressor, driven by high-efciency
permanent magnet DC motor to improve
the energy efciency greatly. The high-
efciency oil supply and oil separation
parts ensure the low friction, low noise,
stable and reliable operation of the
compressor.
Low sound power level EC fans,
together with high efciency DC inverter
motor,greatly reducing the power
consumption. Special 0-91Hz stepless
variable frequency speed regulation
ensures the stable and reliable operation
of the unit.
2
High efcient parts and unique design ensure the chiller high efciency COP up to 3.0.
Compact design, small footprint
‘Y’ shape design , small oor area, only 1.56m2,
28% footprint can be reduced.
Modular design, exible combination
The unit adopts modular design, and max.16 modules can be combined in each group, which can meet the load
demand of different buildings. The combination can be "full inverter units solution" or “inverter units and fixed
speed units solution”.
Full inverter units solution
【Inverter unit(main module)+N×inverter units(auxiliary modules)】
Inverter units and xed speed units solution
【Inverter unit(main module)+N×xed speed units(auxiliary modules)】
2185mm
1000mm 780mm
2000mm
area reduced
2.18m21.56m2

3
Modbus function
Standard ow switch
DC Inverter Rotary DC Inverter Rotary
Standard ow switch in the product, installer no need
to purchase ow switch.
MODBUS interface is reserved for units, which can be connected to building automation systems for centralized
control, easy to realize intelligent management and remote control.
485-232/485-USB Converter
Modbus

4
Precise temperature control
EXV adopts PID control, accurate control refrigerant distribution, outlet water temp. ±5% of the set temperature .
Quick start
With new inverter technology, quick start within 5s, maintain ultra high frequency operation within 1 hour to ensure
the room temperature can reach the set temperature as soon as possible.
2.4 Comfort
Temp.
Operation time
Start Cooling mode
Indoor
temp.
PID controlNormal control
Inverter
unit, Small
temperature
drop
Hot
Cold
±0.5℃
Comfort
Inverter
unit,Quick
cooling
Maximum capacity of hyper cooling and heating
Maximum capacity of normal cooling and heating
5sec
INVERTER

5
Quick start within 5s
Maintain ultra high frequency
operation within 1 hour
Quick start, hyper
cooling and heating
The system will record the operating state before
the power cut. When the power supply is restored,
the system will automatically return to the state
before the power cut without setting again.
Power cut memory function
Shell & tube heat exchanger
The new modular chiller adopts shell & tube heat
exchanger(65/100/130kW) avoid dirty plugging,
higher efciency and reliability.
2.5 High Reliability
Filter drier
Filter drier,absorb moisture in the system, avoid the
emergence of the "ice block"
Pressure sensor control
Through the pressure sensor real-time
monitoring, realize the system quickly, accurately
control, ensure the unit efcient and stable
operation
Three phase fan motor
Three phase fan motor,compared with one
phase fan motor low starting current, high
speed and more stable.

6
Backup operation function
The system has three modules, the actual operation of just two module, if one module malfunction another module
will start automatically according to the water temperature.
operation stop
operation malfunction stop
service
operation

7
3. Specication
Model CA0065EANR
Cooling(T1)
Cooling capacity kW 60
Power input kW 20
Running current A 38
Cooling(T3)
Cooling capacity kW 46
Power input kW 20.5
Running current A 38
Heating
Heating capacity kW 65
Power input kW 19.4
Running current A 36.8
COPR(T1) 3.00
COPR(T3) 2.24
COPH3.35
COPH
*3.85
Max.Power input kW 31.6
Max. running current A 60
Power supply 3N~/380V/50Hz/60Hz
Refrigerant throttle type Electronic expansion valve
Capacity control Stepless
Safety & functional protections
High/low Pressure Protection,Water Lackage
delay Protection, Freeze Protection,Overload
& Overheat Protection, Phase Loss, Phase
Sequence Protection
Compressor
Type Rotary
Quantity 2
Input power KW 9.5×2
Refrigerant
Type - R410a
Charge kg 6×2
Air side heat
exchanger
Type
(Slit n & efcient inner grooved copper tube)
Inner grooved copper pipe & hydrophilic
aluminum n coil
Fan power KW 0.8×2
Fan type Axial ow fan
Fan quantity 2

8
Note: 1.Specications are based on the following conditions:
• (T1) Cooling: chilled water inlet/outlet: 12°C/7°C, and outdoor ambient temp. 35°CDB;
• (T3) Cooling: chilled water inlet/outlet: 12°C7°C, and outdoor ambient temp. 46°CDB;
• Heating COPH : warm water inlet/outlet: 40°C/45°C, and outdoor ambient temp. 7°CDB/6°CWB;
• Heating COPH
*: warm water inlet/outlet: 30°C/35°C
• Water side fouling factor: 0.018m2•°C/kW;
• 1m away in open eld(sound pressure).
2.Due to our policy of innovation, some specications may be changed without notication.
Model CA0065EANR
Water side heat
exchanger
Type Shell and tube heat exchanger
Rated water ow m³/h 10.32
Inlet/outlet pipe R2''
Water dirt coefcient m2.°C/KW 0.018
Standard pressure Mpa 1.0
Water resistance kPa 45
Sound pressure level dB(A) 65
External dimension
Unit length mm 2060
Unit width mm 780
Unit height mm 2170
Package dimension
Unit length mm 2200
Unit width mm 830
Unit height mm 2270
Weight
Unit weight kg 700
Gross weight kg 715
Operation weight kg 750
Otros manuales para CA0065EANR
1
Tabla de contenidos
Otros manuales de Enfriador de Haier

Haier
Haier CI0127MWNA Manual de usuario

Haier
Haier CA0035EAND Manual de usuario

Haier
Haier LC-138WB Manual técnico

Haier
Haier LC-133K Manual técnico

Haier
Haier CA0070AANB Manual de usuario

Haier
Haier CI0193AANB Manual de usuario

Haier
Haier CA0035AANC Manual de usuario

Haier
Haier CA0100MANB Manual de usuario