H2I ONEOF Accuracy Motion Manual de usuario

Accuracy Motion User Manual

1.
1.1
1.2
1.3
1.4
1.5
2.
2.1
2.2
3.
3.1
3.2
3.3
4.
4.1
4.2
5.
5.1
6.
6.1
6.2
6.3
6.4
6.5
7.
7.1
7.2
8.
8.1
8.2
8.3
9.
10.
11.
Introduction . . . . . . . . . . . . . . . 2
Equipment supplied with your ONEOF®
Accuracy Motion . . . . . . . . . . . . . . . . 2
Foreword . . . . . . . . . . . . . . . . . . . . . . 2
Appropriate use . . . . . . . . . . . . . . . . . 2
Limitation of warranty. . . . . . . . . . . . . 3
Typographical conventions . . . . . . . . 4
Safety and environment . . . . . 5
Environmental conditions. . . . . . . . . . 5
Safety and precautions for use . . . . . 5
General description . . . . . . . . . 7
Introduction . . . . . . . . . . . . . . . . . . . . 7
Description. . . . . . . . . . . . . . . . . . . . . 7
Technical specifications . . . . . . . . . . . 9
Handling and storage . . . . . . 10
Handling (safety) . . . . . . . . . . . . . . . 10
Transport . . . . . . . . . . . . . . . . . . . . . 10
Installation . . . . . . . . . . . . . . . 11
Installation and commissioning . . . . . 11
Using the application . . . . . . 13
Accuracy2 interface. . . . . . . . . . . . . . 13
Accuracy Tab. . . . . . . . . . . . . . . . . . . 14
Data tab. . . . . . . . . . . . . . . . . . . . . . . 21
Measurement parameters . . . . . . . . . 23
Application settings . . . . . . . . . . . . . . 30
Maintenance. . . . . . . . . . . . . . 31
Cleaning the device. . . . . . . . . . . . . . 31
Periodic maintenance . . . . . . . . . . . . 31
Troubleshooting . . . . . . . . . . 32
The device is not detected by your
computer . . . . . . . . . . . . . . . . . . . . . . 32
The device is not detected by your
tablet . . . . . . . . . . . . . . . . . . . . . . . . . 32
The device does not work correctly. . 32
Recycling . . . . . . . . . . . . . . . . 33
Annexes . . . . . . . . . . . . . . . . . 34
Glossary . . . . . . . . . . . . . . . . . 35
Table of content
Table of content 1|36

1.
1.1
1.2
1.3
Introduction
Manual version : 0.1 - 02.2022
This chapter contains basic information about the structure of the document. Before handling
the device, the user must read this document.
Equipment supplied with your ONEOF® Accuracy Motion
Accuracy Motion device
Power supply 5V / 0.5A
USB cable
Holding rubber bands (X2)
Quick start Guide
Foreword
This manual is intended for all users of an H2i Sàrl ONEOF® acoustic measuring device. It
contains all the information necessary for its installation, commissioning, periodic maintenance
and troubleshooting.
This manual has been compiled by Petitpierre SA with the same care as your acoustic
measurement device of which it is an inseparable part. If you have any questions or
misunderstandings, please contact your supplier immediately.
It is recommended that a copy of this manual should be given to anyone who may use the
device.
When ordering parts or maintenance, please indicate :
• the type and serial number of your device,
• your exact address,
• the reference and type of the part to be replaced,
Petitpierre SA
Route de l'Europe 7
CH-2017 Boudry
+41 (0)32 843 44 22
Any partial or total reproduction or communication of this document to third parties without prior
written authorization is prohibited.
We reserve the right to change the contents of this document without notice.
Appropriate use
The device is intended for the precision acoustic measurement of watch parts. It can only be
used by trained and authorized personnel.
This system is not intended to measure 100% of watches and it may be possible that
some of them are not adapted to this device.
The device can only be used in conjunction with the corresponding software developed and
supplied by H2i Sàrl.
The use of materials other than those described in this operating manual (e.g. unauthorized
substances) is prohibited.
The instructions in this user's manual must be followed, especially the safety
instructions.
Introduction 2|36

1.4 Limitation of warranty
Even though the device and its software have been tested, it is strongly recommended to make
a backup of the database before updating the software.
When the database is remote, the IT department takes care of the backup. If the database is
local, it is possible to copy the data file (oneof.dat) available in the link Application data folder
from the settings.
[See Application settings, page 30]
Petitpierre SA and H2i Sàrl are not responsible for :
• misuse of the device ;
• unauthorized modification (voluntary or not) ;
• failure to follow the instructions and recommendations in the various manuals supplied with the
device and software ;
• non-compliance with the safety instructions in the various manuals ;
• damage related to the use of the device, in particular any loss of data or financial loss that may
be related to the use of the software or the device.
The warranty will be null and void if it is found that the malfunction is due to abuse,
misuse, unauthorized or inadequate maintenance or service, accidental deterioration,
improper storage conditions, or use of the product outside of its stated limits, outside of
its specifications, contrary to the instructions in this manual, or following
recommendations other than those of the manufacturer.
Each Accuracy Motion is tested before delivery.
Introduction 3|36

1.5
(1)
(2)
(3)
Typographical conventions
The styles used in this manual are the following:
Designation Definition Example
Ordered list
Used in conjunction with the
illustration numbers, preceded by
the corresponding numbers.
First element
Second element
Etc...
Software
commands
All software commands, buttons,
function keys, windows and the like
used in the manual is indicated in
bold and italics.
The On button (Switching on) allows
to switch the group on.
Procedure
Each step of the procedure to be
followed by the user is preceded by
a letter.
A. Remove the cover plate.
B. Replace the defective
element.
C. Put the sheet back on.
Cross-
reference Link to further information. [See Typographical
conventions, page 4]
Attention
Used to refer to a potentially
hazardous situation that, if not
avoided, may result in minor injury or
property damage.
ATTENTION
The unit should be
transported upright and
should not be subject to
shock.
Note
Used to accompany a general
remark or a purely informative
comment.
The unit has been checked,
adjusted and tested in our
workshops.
Link to glossary Used to link a word to its definition in
the Glossary section. Lift angle.
Introduction 4|36

2.
2.1
2.2
2.2.1
2.2.2
Safety and environment
This chapter defines the safety instructions for the proper operation of the Accuracy Motion
device and the associated software. It also describes the handling and storage conditions.
Environmental conditions
The Accuracy Motion device must be used exclusively indoors.
The electrical safety of the device is guaranteed only if the electrical installation of the
building complies with the regulations for industrial buildings, and if it functioning
properly.
The device should not be exposed to heat, dust or excessive moisture.
The device should not be close to a powerful sound source as this may distort the
results.
Operating values
Designation Value Unit
Max. ambient humidity 79 %
Ambient work place temperature 5-35 °C
Relative temperature range -15 +15 °C
Safety and precautions for use
Importance of safety instructions
The safety and protection instructions in this manual must be followed to avoid injury,
property damage or environmental pollution.
In the same way, the legal provisions, accident prevention and environmental protection
measures, as well as the technical regulations to ensure safe and suitable working conditions
applicable in the country and at the location where the device is used must be observed.
Use of the device in any manner other than that described in this manual may void the
warranty.
General safety instructions and signs
Repair and maintenance work should only be carried out by a qualified service
technician designated by the manufacturer.
Heed all warnings and follow all instructions provided on the device and in the the device
and in the documentation.
The device should only be connected to the indicated power sources.
Never use components other than those supplied by the manufacturer.
The device must be installed on a flat, dry and stable surface.
Never force or stop the motor movements by hand.
The device must be used with the supplied software and accessories approved by the
manufacturer.
Safety and environment 5|36

2.2.2.1
2.2.2.2
2.2.3
2.2.3.1
2.2.3.2
Mechanical hazards
There is a risk of entrapment. Be careful not to leave your hand between the head and the
base of the device during operation.
Electrical hazards
It is forbidden to open the device in any way.
A faulty main power supply (outside the range specified in the device features section) or
a faulty cable can damage the device. If it is necessary to use the 2nd usb port, a
standard usb charger (5v) can be used.
To turn the power off, disconnect the power cable by pulling on the connector, never pull
directly on the cable.
Safety symbols
No specific signage is required for the Accuracy Motion.
If technical developments involve risks, symbols are placed on different parts of the device to
draw attention to a potential danger, to prohibited operations or to the obligation to wear safety
equipment.
Alert symbols
Symbol Description
ATTENTION :
Warning (general), consult documentation.
Obligation Symbols
Symbol Description
Mandatory instructions:
Only persons who have been trained in the handling of the device and who
know these instructions may work on it.
Safety and environment 6|36

3.
3.1
3.2
3.2.1
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
General description
This chapter contains general information about the ONEOF® Accuracy Motion.
Introduction
The ONEOF® Accuracy Motion is an automated acoustic measuring instrument with backlash-
free positioning. It is designed to measure watches or mechanical movements in production,
laboratory or after-sales service.
One connector allow the device to be controlled by the software. The other one is an optionnal
power supply (iPhone/iPad only).
No other access to the components of the device is possible outside the technical services of
Petitpierre SA and H2i Sàrl.
Description
Overall view
FIG. 3-1 - Accuracy Motion (Overall view)
Sensor
Cart
Measuring head
Alpha axis
Base
USB Input 1
USB Input 2 (iPhone/iPad only)
Beta axis
The motor control, based on an inertial measurement unit, allows to reach any position of the
half-sphere with the required degree of accuracy. The device is supplied with a software
allowing the control of several devices in real time. The software is also equipped with a
sequence editor to automate the testing process. All data collected by the device can then be
stored locally or in a database.
General description 7|36

3.2.2
3.2.3
(1)
(2)
(3)
(4)
(5)
(6)
Rotation axes
FIG. 3-2 - Accuracy Motion (Rotation axes)
The Accuracy Motion rotation axes are:
• Alpha (1) corresponds to movement from top (0°) to bottom (90°).
The position in the illustration corresponds to 0°.
• Beta (2) corresponds to the rotation movement (360°), the positive direction is
counterclockwise.
The position in the illustration corresponds to 0°.
Measuring positions
The Accuracy Motion has 6 standard pre-registered positions which are the most commonly
used positions, but the sequences also allow measurement at all intermediate positions.
FIG. 3-3 - Accuracy Motion (Measuring positions)
DU (Dial up)
DD (Dial down)
CD (Crown down)
CR (Crown right)
CU (Crown up)
CL (Crown left)
General description 8|36

3.3
3.3.1
3.3.2
Technical specifications
Approximate dimensions and weight
Designation Value Unit
Length x Width 25 x 12 cm
Height 25 cm
Weight 1 kg
Power supply
Designation Value Unit
Type of cable USB type-C
Voltage 5 V
Current 0.5 A
General description 9|36