GW Instek APS-7051 Manual de usuario

Programmable AC Power Source
APS-7051/APS-7101
USER MANUAL
ISO-9001 CERTIFIED MANUFACTURER

This manual contains proprietary information, which is protected by
copyright. All rights are reserved. No part of this manual may be
photocopied, reproduced or translated to another language without
prior written consent of Good Will company.
The information in this manual was correct at the time of printing.
However, Good Will continues to improve products and reserves the
rights to change specification, equipment, and maintenance
procedures at any time without notice.
Good Will Instrument Co., Ltd.
No. 7-1, Jhongsing Rd., Tucheng Dist., New Taipei City 236, Taiwan.

3
Table of Contents
SAFETY INSTRUCTIONS .................................................. 4
GETTING STARTED.......................................................... 8
APS-7000 Series Overview......................9
Appearance .......................................... 12
OPERATION .................................................................. 18
Set Up.................................................. 20
Basic Operation ................................... 40
Preset Settings..................................... 56
Test Mode Function ............................. 60
COMMUNICATION INTERFACE ..................................... 70
Interface Configuration ........................ 71
FAQ............................................................................... 90
APPENDIX ..................................................................... 92
Firmware Update ................................. 92
APS-7000 Default Settings ................... 94
APS-7000 Specifications....................... 95
APS-7000 Dimensions.......................... 98
INDEX ..........................................................................100

APS-7000 Series User Manual
4
SAFETY INSTRUCTIONS
This chapter contains important safety
instructions that you must follow during
operation and storage. Read the following before
any operation to ensure your safety and to keep
the instrument in the best possible condition.
Safety Symbols
These safety symbols may appear in this manual or on the
instrument.
WARNING
Warning: Identifies conditions or practices that
could result in injury or loss of life.
CAUTION
Caution: Identifies conditions or practices that
could result in damage to the APS-7000 or to other
properties.
DANGER High Voltage
Attention Refer to the Manual
Protective Conductor Terminal
Earth (ground) Terminal

SAFETY INSTRUCTIONS
5
Do not dispose electronic equipment as unsorted
municipal waste. Please use a separate collection
facility or contact the supplier from which this
instrument was purchased.
Safety Guidelines
General
Guideline
CAUTION
Do not place any heavy object on the APS-7000.
Avoid severe impact or rough handling that
leads to damaging the APS-7000.
Do not discharge static electricity to the APS-
7000.
Use only mating connectors, not bare wires, for
the terminals.
Do not block the cooling fan opening.
Do not disassemble the APS-7000 unless you are
qualified.
(Measurement categories) EN 61010-1:2010 specifies the
measurement categories and their requirements as follows. The
APS-7000 doesn’t fall under category II, III or IV.
Measurement category IV is for measurement performed at the
source of low-voltage installation.
Measurement category III is for measurement performed in the
building installation.
Measurement category II is for measurement performed on the
circuits directly connected to the low voltage installation.
0 is for measurements performed on circuits not directly
connected to Mains.
Power Supply
WARNING
AC Input voltage range: 115/230 Vac ± 15%
Frequency: 50/60Hz
To avoid electrical shock connect the protective
grounding conductor of the AC power cord to
an earth ground.

APS-7000 Series User Manual
6
Cleaning the APS-
7000
Disconnect the power cord before cleaning.
Use a soft cloth dampened in a solution of mild
detergent and water. Do not spray any liquid.
Do not use chemicals containing harsh material
such as benzene, toluene, xylene, and acetone.
Operation
Environment
Location: Indoor, no direct sunlight, dust free,
almost non-conductive pollution (Note below)
Relative Humidity: 20%~ 80%, no condensation
Altitude: < 2000m
Temperature: 0°C to 40°C
(Pollution Degree) EN 61010-1:2010 specifies the pollution degrees
and their requirements as follows. The APS-7000 falls under degree
2.
Pollution refers to “addition of foreign matter, solid, liquid, or
gaseous (ionized gases), that may produce a reduction of dielectric
strength or surface resistivity”.
Pollution degree 1: No pollution or only dry, non-conductive
pollution occurs. The pollution has no influence.
Pollution degree 2: Normally only non-conductive pollution
occurs. Occasionally, however, a temporary conductivity caused
by condensation must be expected.
Pollution degree 3: Conductive pollution occurs, or dry, non-
conductive pollution occurs which becomes conductive due to
condensation which is expected. In such conditions, equipment
is normally protected against exposure to direct sunlight,
precipitation, and full wind pressure, but neither temperature
nor humidity is controlled.
Storage
environment
Location: Indoor
Temperature: -10°C to 70°C
Relative Humidity: ≤80%, no condensation
Disposal
Do not dispose this instrument as unsorted
municipal waste. Please use a separate collection
facility or contact the supplier from which this
instrument was purchased. Please make sure
discarded electrical waste is properly recycled to
reduce environmental impact.

SAFETY INSTRUCTIONS
7
Power cord for the United Kingdom
When using the instrument in the United Kingdom, make sure the
power cord meets the following safety instructions.
NOTE: This lead/appliance must only be wired by competent persons
WARNING: THIS APPLIANCE MUST BE EARTHED
IMPORTANT: The wires in this lead are coloured in accordance with the
following code:
Green/ Yellow:
Earth
Blue:
Neutral
Brown:
Live (Phase)
As the colours of the wires in main leads may not correspond with
the coloured marking identified in your plug/appliance, proceed
as follows:
The wire which is coloured Green & Yellow must be connected to
the Earth terminal marked with either the letter E, the earth symbol
or coloured Green/Green & Yellow.
The wire which is coloured Blue must be connected to the terminal
which is marked with the letter N or coloured Blue or Black.
The wire which is coloured Brown must be connected to the
terminal marked with the letter L or P or coloured Brown or Red.
If in doubt, consult the instructions provided with the equipment
or contact the supplier.
This cable/appliance should be protected by a suitably rated and
approved HBC mains fuse: refer to the rating information on the
equipment and/or user instructions for details. As a guide, a cable
of 0.75mm2should be protected by a 3A or 5A fuse. Larger
conductors would normally require 13A types, depending on the
connection method used.
Any exposed wiring from a cable, plug or connection that is
engaged in a live socket is extremely hazardous. If a cable or plug is
deemed hazardous, turn off the mains power and remove the cable,
any fuses and fuse assemblies. All hazardous wiring must be
immediately destroyed and replaced in accordance to the above
standard.

APS-7000 Series User Manual
8
GETTING STARTED
This chapter describes the power source in a
nutshell, including its main features and front /
rear panel introduction.
APS-7000 Series Overview ......................................... 9
Series lineup ........................................................................................9
Operating Area ...................................................................................9
Main Features ...................................................................................10
Accessories ........................................................................................11
Appearance.............................................................. 12
Front Panel........................................................................................12
Rear Panel..........................................................................................15
APS-7051 ....................................................................................15
APS-7101 ....................................................................................15
Status Bar Icons................................................................................17

GETTING STARTED
9
APS-7000 Series Overview
Series lineup
The APS-7000 series consists of 2 models, the APS-7051 and the
APS-7101, differing only in capacity. Note that throughout the user
manual, the term “APS-7000” refers to both the APS-7051 and APS-
7101, unless stated otherwise.
Model name
Max. Output Current
Power Rating
Output Voltage
APS-7051
2.5A/1.25A/0.63A
500VA
0~1000 Vrms
APS-7101
5.0A/2.5A/1.25A
1000VA
0~1000 Vrms
Operating Area
Voltage (V)
Current (A)
0
0.5
1
0
1.5
2
2.5
200 400 600 800 1000
200 250 400 500 800 1000
2.5
2
1
0.63
0.5
APS-7051 Output Operating Area
250V Range 500V Range 1000V Range
1.25

APS-7000 Series User Manual
10
Voltage (V)
Current (A)
0
1
2
0
3
4
5
200 400 600 800 1000
200 250 400 500 800 1000
5
4
2
1.25
1
APS-7101 Output Operating Area
250V Range 500V Range 1000V Range
2.5
Main Features
Performance
Low output ripple and noise
Excellent and feature-rich measurement
capacity
Standard maximum output voltage is 1000Vrms
Maximum frequency of 500Hz.
Features
OCP, OPP and OTP protection
Variable voltage, frequency and current limiter
Test function to simulate line voltage and
frequency variations
Large 4.3 inch TFT panel
Globally adjustable power inlet not restricted by
the power supply environment
USB interface is equipped as standard with the
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Distribución de energía CA de GW Instek

GW Instek
GW Instek APS-7100 Manual del propietario

GW Instek
GW Instek APS-7000 Series Manual de usuario

GW Instek
GW Instek ASR-6000 Series Manual de usuario

GW Instek
GW Instek APS-1102 Manual de usuario

GW Instek
GW Instek ASR-2000 Series Manual del propietario

GW Instek
GW Instek APS-7050E Manual de usuario

GW Instek
GW Instek ASR-6000 Series Manual de usuario

GW Instek
GW Instek APS-7100 Manual del propietario

GW Instek
GW Instek APS-1102A Manual de usuario