Grodan GroSens MultiSensor
Installation
Guide
Grodan
Industrieweg 15
Postbus 1160, 6040 KD Roermond
The Netherlands
T +31 (0)475 35 30 20
F +31 (0)475 35 37 16
www.grodan.com
www.linkedin.com/company/grodan
www.twitter.com/grodan
Grodan is a registered trademark of ROCKWOOL
INTERNATIONAL A/S. © ROCKWOOL B.V.
Grodan 2017. All rights reserved.

GroSens - alternative for multiple extenders
• Every 100 meters, an extender is needed to carry the signal
• Instead of an extender, a switch box can be used to carry the LAN signal into the greenhouse
• Every switchbox needs power in the greenhouse - a power plug should be available.
• PoE after the switch to receiver
• Benets: Flexibility in connecting other items in the greenhouse that require an internet signal
1
Cables placed in
the greenhouse,
including
extenders or
switches
2
Unpack Smartbox
and install smartbox
at location grower
3
Activate Smartbox
and ll out software
4
Test Receiver and
Sensors in the ofce:
- Network connection
- Add in software:
address sensors to
irrigation sections
5
Place Receiver in
the greenhouse
and place Sensors
in slabs
6
Connect and install
Converter » set
values for readings
Precision Growing
With its focus on using the minimum
input materials to generate the
maximum output, Precision Growing is
the most efcient and effective form of
growing. It not only reduces growing
costs but increases crop yield and
quality. What’s more, this form of
growing actively contributes to
sustainable horticulture.
Installation procedure step 1

Layout cables in the Greenhouse
Connecting the Smartbox
PoE Injector
PoE Injector
GroSens Smartbox
Extender
Network Switch
Network switch
GroSens Receiver
GroSens Receiver
GroSens Receiver
100m
100m 100m
100m
Installation procedure step 1
PoE Injector
When the smarbox is connected, it will nd an IP address and displays it in the front
screen. Type the IP address in the internet browser, it will give access to the smartbox
software. Preferred browsers are Google Chrome and Mozilla Firefox.
Explorer should be 10 or higher.
1
Cables placed in
the greenhouse,
including
extenders or
switches
2
Unpack Smartbox
and install smartbox
at location grower
3
Activate Smartbox
and ll out software
4
Test Receiver and
Sensors in the ofce:
- Network connection
- Add in software:
address sensors to
irrigation sections
5
Place Receiver in
the greenhouse
and place Sensors
in slabs
6
Connect and install
Converter » set
values for readings
Installation procedure step 2

Installation procedure step 3
Activate the system – software
Sunrise/Sunset and Lighting setup
1. Create Initial User: the grower
2. Fill in email address and Password for the grower.
Click by “Settings” on “Sunrise/Sunset and Lighting setup”
1. Select natural lighting
2. Click on “Look up longitude and latitude”.
A new tab will open.
Login as administrator.
If you or grower forgot username and password you can always log in with:
1
Cables placed in
the greenhouse,
including
extenders or
switches
2
Unpack Smartbox
and install smartbox
at location grower
3
Activate Smartbox
and ll out software
4
Test Receiver and
Sensors in the ofce:
- Network connection
- Add in software:
address sensors to
irrigation sections
5
Place Receiver in
the greenhouse
and place Sensors
in slabs
6
Connect and install
Converter » set
values for readings
Installation procedure step 3

Installation procedure step 3 Installation procedure step 3
1. Fill in the “Place Name” and click on “Find”. The
longitude and latitude will be given.
2. Copy longitude and latitude data to Sunrise/Sunset
and Lighting setup” screen.
3. Click on “Apply”.
1. Go back to Sunrise/Sunset and Lighting setup”
screen
2. Click on “Apply”
The GPS coordinates will determine the sunrise and
sunset based on the co-ordinates and plot daylight
period in the graphs.
During the day, data is sent every 3 minutes, during the
night data is sent every 30 minutes.
If you choose articial light, you can set the time interval,
data will come in every 3 minutes:
For example: if you choose 02.00 till 20.00, data of the
sensors will be sent every 3 minutes.
Click on “Apply”

1. Select time zone
2. Mark “use internet time”
3. Click on “Apply”
On this screen you will nd the password and email
address you created. Here you can add other addresses.
Please note that:
Notications should be set at none! Otherwise all alerts will be sent to the email
address, also the harmless ones.
The User level for the main user should be set as administrator to access all functions!
If you choose read only you can only access graphs
Installation procedure step 3 Installation procedure step 3
Manage Users
Click on “system”, “manage users”
Date, Time and Time zone
Click by “System” on “Date, Time, and Timezone”

Installation procedure step 3
Update
Click by “System” on “Update”
The system will look for available software updates.
Test Receiver and Sensor
100m
1
Cables placed in
the greenhouse,
including
extenders or
switches
2
Unpack Smartbox
and install smartbox
at location grower
3
Activate Smartbox
and ll out software
4
Test Receiver and
Sensors in the ofce:
- Network connection
- Add in software:
address sensors to
irrigation sections
5
Place Receiver in
the greenhouse
and place Sensors
in slabs
6
Connect and install
Converter » set
values for readings
Installation procedure step 4
PoE Injector GroSens Receiver

Installation procedure step 4
LED’s Both link and power light of receiver should be green
After activation, both LEDs will light up, after a few
minutes, only the green LED will glow:
• The green LED indicates round-trip communication
with the GroSens Smartbox.
• The red LED indicates a communication problem
with the GroSens Smartbox.
LED’sTEST button
You can check in the overview screen if the Receiver and
Sensor data are coming in (status lights should be green
or yellow triangles )
If a red circle shows up the device is not working,
action is needed (see installation manual).
Installation procedure step 4
Test Receiver and Sensors - in software display
Click by “Dashboard” on “Devices”or click directly on:

Click on:
Create Slab Types
Click by “Setting” on “Slab types”
1. Fill in a name (together with grower)
2. Choose a slab by “Copy From”
3. Click on “Apply”
Fill in Length, Width,
Height, Brand of the slab,
Crop and the number of
used spacers. You can
select an item or ll in a
new item.
The new slab type is made (Fe: Location A)
Click on:
Add
Installation procedure step 4 Installation procedure step 4

Create sections Assign the Sensors to a section
Click by “Settings” on “Create New Section” You can select the sensors in the “Monitoring” tab.
Click on “Apply”.
After apply, Sensor will be displayed in the overview.
You can delete a sensor from a section by clicking
on an X.
1. Dene a section name (together with the grower).
2. Select the right Media Type - the ones you just made
(see former sheets).
3. Click on “Apply”.
Installation procedure step 4 Installation procedure step 4
Otros manuales para GroSens
3
Tabla de contenidos
Otros manuales de Accesorios de Grodan