GRASS VALLEY SP1 Manual de usuario

20 February, 2010
User Manual — Remote Control(SP1) —
T2
INTELLIGENT DIGITAL DISK RECORDER

2T2
―
User Manual ― Remote Control(SP1) ―
Cautions
(1) It is prohibited to copy a part or all of this product without prior permission.
(2) Thecontentsorspecicationsofthisproductmaybechangedwithoutprior
notice.
(3) We have prepared the contents of this product to the best of our ability;
however if you have any questions about the contents, or if there are any errors
ormissingitems,pleasecontactGrassValley.
(4) Howeverwedonottakeanyresponsibilityformalfunctionsarisingfromuse,
irrespective of the points outlined in (3).
(5) Irrespectiveofwhetheritwasduetoausageerror,GrassValleytakesno
responsibilityforextraordinary,incidentalorderivativeclaims,includingthose
forlostearningsgeneratedbytheapplicationofthisproduct.
(6) Itisprohibitedtoanalyze,reverseengineer,decompileordisassembleanyof
theitemsincludedwiththisproduct,includingthesoware,hardwareand
manual.
(7) MicrosoandWindowsareregisteredtrademarksoftheMicroso
Corporation, USA.
(8) DVCPROHDisthetrademarkofthePanasonicCorporation.
(9) HDVandHDVlogosarethetrademarksofSonyCorporationandVictor
CompanyofJapan,Limited(JVC).
(10)
Otherproductnamesorrelatedbrandnamesaretrademarksorregistered
trademarks of their respective companies.
About this manual
The screens used as examples in this manual are those of the development•
stage,sotheymayvaryfromthoseinthenalproduct.
If there are any variations between the explanation in this manual and the•
actualapplicationmethod,priorityisgiventotheactualapplicationmethod.
Thismanualiswrienforpeoplewhohaveabasicknowledgeofhowtousea•
computer. If there are no special instructions, perform the same operation as a
normal computer operation.
In this manual, the system of the T2 is called "Workstation".•

3T2
―
User Manual ― Remote Control(SP1) ―
Warning
Health precautions•
Inrarecases,ashinglightsorstimulationfromthebrightlightofacomputer
displayorTVmonitormaytriggertemporaryepilepticseizuresorloss
of consciousness. It is believed that even individuals whom have never
experienced such symptoms may be susceptible. If you or close relatives have
experiencedanyofthesesymptoms,consultadoctorbeforeusingthisproduct.
T2
User Manual – Remote Control(SP1) –
20 February, 2010
Copyright © 2009-2010 Thomson
All rights reserved.

4T2
―
User Manual ― Remote Control(SP1) ―

T2
―
User Manual ― Remote Control(SP1) ―
5
Remote Control
Overview
WiththeremotecontrolsoftheT2,thefollowingcontrolsandactionsare
available.
Asadevice,T2receivescommandsinputviatheREMOTERS422port•
on the T2 rear panel.
T2 controls external devices with the commands output via the•
REMOTERS422portontheT2rearpanel.
Asadevice,T2receivescommandsinputviaEthernet.•
T2controlsexternaldeviceswithcommandsoutputviaEthernet.•
T2supportsBVWprotocolpartially(RS422only).•
T2supportsAMPprotocolpartially(Ethernetonly).•
AccordingtotheGPIinput,thecorrespondingactionsareperformed.•
AccordingtothePlaylist>Eventseings,thecorrespondingGPI•
triggersareoutput.
RecordingisavailableinR1-Remotemode.(AMPprotocolonly)•
Functions
1 R1 - VTR mode
Asacontroller(master),T2controlstheexternaldevice(VTR).•
When"In-OutRec"isexecuted,T2controlstheVTRsoastocapture•
therangebetweenthespeciedtimecodes.
Section 1

T2
―
User Manual ― Remote Control(SP1) ―
6
Section 1 ―
Remote Control
Settings for using AMP commands
BeforeusingtheAMPcommands,makesurethatthenetworkseings
have been established as below.
* The procedures in the Workstation mode are explained here.
1 Click the ConfigbuonontheT2,chooseGeneral>Network1/2 to open
theseingdialog,andsettheIPaddressoftheT2.
2 Click the ConfigbuonontheT2,chooseR1>Timecode & Remote to
opentheseingdialog,andsettheIPaddressoftheconnecteddevice.
2 P1/P2 – Remote mode
As a device (slave), T2 receives the commands sent by external controllers.•
SupportsBVWprotocolandAMPprotocol.•
*Seepage11fordetailsonBVWcommands,andpage13fordetailson
AMPcommands.

T2
―
User Manual ― Remote Control(SP1) ―
7
Functions
3 R1-Remote mode
OnR1,T2worksasadevice(slave)andreceivescommandssentfrom•
externalcontrollers.(SupportsAMPprotocolonly.)
*FordetailsonAMPcommands,see"AMP"onpage13.
TheRemoteseingsinCongonlytakeeectonVTRcontrols.They•
don'ttakeeectintheR1-Remotemode.
4 GPI input
ViatheGPIinputport(6pins),T2canbecontrolled.•
Inputseingscanbespeciedontheseingdialog,displayedby
pressingtheConfigbuonandchoosingGPI.
* The procedures in the Workstation mode are explained here.
GPI Input settings
* See the "T2 User Manual – Workstation mode –" for details.
Triggerchannel(R1,P1,P2):Multiplechannelscanbesimultaneously•
chosen.
TriggerAction•
play•
stop•
record•

T2
―
User Manual ― Remote Control(SP1) ―
8
Section 1 ―
Remote Control
rewind•
fast fwd•
cue start/end•
eject•
preview•
cue next/prev event•
VARplayback•
Active•
High•
Low•
*Iftheoperationcorrespondingtotheinputtriggercannotbeexecuted,
nothinghappens.
*RegardlessoftheoperationmodeorlockstatusoftheGUI,GPIinputs
can be received.
*Whenremote-controllingT2,donotuseRS422andGPIsimultaneously.
DoingsomaydisableRS422controls.
5 GPI output
ViatheGPIoutputport(6pins),triggersareoutputaccordingtothe•
T2 operation.
OutputPinseingscanbespeciedontheseingdialog,displayed
bypressingtheConfigbuonandchoosingGPI,whileoutputTrigger
seingscanbespeciedontheseingdialog,displayedbyright-
clickingonaneventlist,andchoosingProperties>GPI.
* The procedures in the Workstation mode are explained here.
*GPIoutputcanbeoutputonlywhenissuedfromcontentloadedon
theP1channel.

T2
―
User Manual ― Remote Control(SP1) ―
9
Functions
GPI Output settings
* See the "T2 User Manual –Workstation mode –" for details.
Name•
Active•
High•
Low•
GPI tab

T2
―
User Manual ― Remote Control(SP1) ―
10
Section 1 ―
Remote Control
Tabla de contenidos