1 General
Rc 1/2in.
GAS
CONNECTION
WATER
CONTENT
WATER
CONNECTION 28mm copper flow
at right return at left
LIFT
WEIGHT
240V ~ 50HZ, fused 3A.
ELECTRICITY
SUPPLY
1.6 Litre
(0.35 gal)
31.5 kg
(69.5 lb)
48.0 kg
(106 lb)
TOTAL
WEIGHT
60
DATA TABLE 1.
MODEL
The Seasonal Efficiency Domestic Boilers UK (SEDBUK)
is 86.9%.
ThevalueisusedintheUKGovernment’sStandardAssessment
Procedure (SAP) for energy rating of dwellings. The test data
from which it has been calculated have been certified by B.S.I.
1.5 Gas Supply
The gas installation must be in accordance with the current
issue of BS6891.
The supply from the governed meter must be of adequate size
toprovideasteadyinletworkingpressureof20mbar(8inwg)at
the boiler.
Oncompletion,testthegasinstallationforsoundnessusingthe
pressuredropmethodandasuitableleakdetectionfluid,purge
in accordance with the above standard.
1.6 Electrical Supply
WARNING. This boiler must be earthed.
All system components shall be of the approved type and be
wired and connected in accordance with the requirements of
thecurrentissueofBS7671andanyapplicablelocalregulations.
Connection of the boiler and system controls to the mains
supply must be through a common isolator and must be fused
3Amaximum. Thismethodofconnectionshouldbe,preferably,
by a double pole isolating switch, provided it has a minimum
contact separation of 3mm on both poles. This should be
readily accessible and preferably adjacent to the appliance. It
shouldsupplytheapplianceonlyandbeeasilyidentifiableasso
doing.
Alternatively, an unswitched shuttered socket outlet and 3A
fused 3 pin plug both to the current issue of BS1363 may be
used, provided that they are not used in a room containing a
bath or shower.
Wiring to the boiler must be PVC insulated type to the current
issue of BS6500 Table 16.
1.7 Condensate
The boiler condensate should, if possible, be discharged into
thehouseholdinternaldraining system,thatis,sinkor washing
machine drain. If this is not practicable, discharge can be
external, into the household drainage system or a purpose
designed soakaway
Theboilerisfittedwithasafetydevicetopreventtheboilerfrom
working if the condensate pipe gets blocked by either ice or
debris.
It is, therefore, recommended that any external condensate
drain pipe is insulated to prevent it freezing up.
Alternatively,alargerdiameterpipecanbeusedandinsulated.
The condensate drain pipe should be checked during any
servicing and any debris found removed.
Refer to the British Gas publication “Guidance Note for the
Installation of Domestic Condensing Boilers”for further
information.
1.8 Heating System Controls
The heating system should have installed: a programmer and
room thermostat controlling the boiler.
Thermostatic radiator valves may be installed in addition to the
room thermostat.
Note: For further information, see The Building Regulations
1991-Conservationoffuelandpower,1995edition-Appendix
G, table 4b.
RANGE RATING
NOMINAL kW
HEAT INPUT
(GROSS) Btu/h
NOMINAL kW
HEAT
OUTPUT Btu/h
10.16 16.94 18.64 20.33
34,680 57,800 63,584 69,350
9.40 15.67 17.24 18.81
32,100 53,500 58,800 64.150
APPROX m3h
GAS
RATE ft3h
4.5 11.8 14.3 17.0
1.8 4.7 5.7 6.8
0.96 1.6 1.77 1.9
34 57 62.5 68
BURNER INJECTOR MARKING: 60N
8.79 14.65 16.12 17.58
30,000 50,000 55,000 60,000
LOW MIN MID MAX
TABLE 2.
Energysaver 60
BURNER m bar
SETTING (HOT)
PRESSURE in.w.g
NOMINAL kW
HEAT
OUTPUT Btu/h
CONDENSING
1.9 Anti-theft Kits
Anti-theft kits are available for these appliances, contact
Hepworth Heating Ltd. for further information.