Glas Craft Auto Probler P2 Manual de usuario

Auto Probler P2
Dispense Gun
USER MANUAL
For use with non-ammable foam and polyurea.
Not for use in explosive atmospheres.
90-110 psi (0.62-0.76 MPa, 6.2-7.6 bar) Air Inlet Pressure Range
3500 psi (24.1 MPa, 241 bar) Maximum Static Fluid Pressure
Important Safety Instructions
Read all warnings and instructions in
this manual. Save these instructions.
Models:
GCP4RA
GCP4R0
GCP4R1
GCP4R2
GCP4R3
GCP4R4
GCP4R5
24X636
g
ti19820a

Table Of Contents
Section 1 Installation
Warnings ............................................................................................................................................................ 3
Introduction ........................................................................................................................................................ 7
Standard Equipment .......................................................................................................................................... 8
Equipment Assembly ......................................................................................................................................... 9
Section 2 Operation
Start-up Instructions ........................................................................................................................................... 11
Section 3 General Information
Assembly Drawings ............................................................................................................................................. 13
Maintenance ........................................................................................................................................................ 15
Options ................................................................................................................................................................ 20
Section 4 Warranty and Reference Information
Limited Time Warranty ........................................................................................................................................ 25
Technical Assistance ........................................................................................................................................... 26
For Your Reference ............................................................................................................................................. 27
2

3
Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specic risks. When these
symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specic hazard
symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
WARNING
TOXIC FLUID OR FUMES HAZARD
Toxic uids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled or swal-
lowed.
• Read Safety Data Sheet (SDS) for handling instructions and to know the specic hazards of the uids
you are using, including the effects of long-term exposure.
• When spraying, servicing equipment, or when in the work area, always keep work area well ventilated
and always wear appropriate personal protective equipment. See Personal Protective Equipment
warnings in this manual.
• Store hazardous uid in approved containers, and dispose of it according to applicable guidelines.
PERSONAL PROTECTIVE EQUIPMENT
Always wear appropriate personal protective equipment and cover all skin when spraying, servicing equip-
ment, or when in the work area. Protective equipment helps prevent serious injury, including long-term ex-
posure; inhalation of toxic fumes, mists or vapors; allergic reaction; burns; eye injury and hearing loss. This
protective equipment includes but is not limited to:
• A properly tting respirator, which may include a supplied-air respirator, chemically impermeable gloves,
protective clothing and foot coverings as recommended by the uid manufacturer and local regulatory
authority.
• Protective eyewear and hearing protection.
SKIN INJECTION HAZARD
High-pressure uid from dispensing device, hose leaks, or ruptured components will pierce skin. This may
look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.
• Do not point dispensing device at anyone or at any part of the body.
• Do not put your hand over the uid outlet.
• Do not stop or deect leaks with your hand, body, glove, or rag.
• Follow the Pressure Relief Procedure when you stop dispensing and before cleaning, checking, or
servicing equipment.
• Tighten all uid connections before operating the equipment.
• Check hoses and couplings daily. Replace worn or damaged parts immediately.
BURN HAZARD
Equipment surfaces and uid that is heated can become very hot during operation. To avoid severe burns:
• Do not touch hot uid or equipment.

Warnings
4
WARNING
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. Paint or solvent
owing through the equipment can cause static sparking. To help prevent re and explosion:
• Use equipment only in well ventilated area.
• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop
cloths (potential static sparking).
• Ground all equipment in the work area.
• Never spray or ush solvent at high pressure.
• Keep work area free of debris, including solvent, rags and gasoline.
• Do not plug or unplug power cords, or turn power or light switches on or off when ammable fumes are
present.
• Use only grounded hoses.
• Hold gun rmly to side of grounded pail when triggering into pail. Do not use pail liners unless they are
anti-static or conductive.
• Stop operation immediately if static sparking occurs or you feel a shock. Do not use equipment until
you identify and correct the problem.
• Keep a working re extinguisher in the work area.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
• Do not operate the unit when fatigued or under the inuence of drugs or alcohol.
• Do not exceed the maximum working pressure or temperature rating of the lowest rated system compo-
nent. See Technical Data in all equipment manuals.
• Use uids and solvents that are compatible with equipment wetted parts. See Technical Data in all
equipment manuals. Read uid and solvent manufacturer’s warnings. For complete information about
your material, request Safety Data Sheet (SDS) from distributor or retailer.
• Do not leave the work area while equipment is energized or under pressure.
• Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.
• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufac-
turer’s replacement parts only.
• Do not alter or modify equipment. Alterations or modications may void agency approvals and create
safety hazards.
• Make sure all equipment is rated and approved for the environment in which you are using it.
• Use equipment only for its intended purpose. Call your distributor for information.
• Route hoses and cables away from trafc areas, sharp edges, moving parts, and hot surfaces.
• Do not kink or over bend hoses or use hoses to pull equipment.
• Keep children and animals away from work area.
• Comply with all applicable safety regulations.
PRESSURIZED ALUMINUM PARTS HAZARD
Use of uids that are incompatible with aluminum in pressurized equipment can cause serious chemical
reaction and equipment rupture. Failure to follow this warning can result in death, serious injury, or property
damage.
• Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or uids
containing such solvents.
• Do not use chlorine bleach.
• Many other uids may contain chemicals that can react with aluminum. Contact your material supplier
for compatibility..

Important Isocyanate (ISO)
Information
Isocyanates (ISO) are catalysts used in two component
materials.
Isocyanate Conditions
Spraying or dispensing uids that contain isocyanates creates potentially harmful mists, vapors, and atom-
ized particulates.
• Read and understand the uid manufacturer’s warnings and Safety Data Sheet (SDS) to know spe-
cic hazards and precautions related to isocyanates.
• Use of isocyanates involves potentially hazardous procedures. Do not spray with this equipment un-
less you are trained, qualied, and have read and understood the information in this manual and in
the uid manufacturer’s application instructions and SDS.
• Use of incorrectly maintained or mis-adjusted equipment may result in improperly cured material.
which could cause off gassing and offensive odors. Equipment must be carefully maintained and ad-
justed according to instructions in the manual.
• To prevent inhalation of isocyanate mists, vapors and atomized particulates, everyone in the work
area must wear appropriate respiratory protection. Always wear a properly tting respirator, which may
include a supplied-air respirator. Ventilate the work area according to instructions in the uid manufac-
turer’s SDS.
• Avoid all skin contact with isocyanates. Everyone in the work area must wear chemically impermeable
• gloves, protective clothing and foot coverings as recommended by the uid manufacturer and local
regulatory authority. Follow all uid manufacturer recommendations, including those regarding han-
dling of contaminated clothing. After spraying, wash hands and face before eating or drinking.
• Hazard from exposure to isocyanates continues after spraying. Anyone without appropriate personal
protective equipment must stay out of the work area during application and after application for the
time period specied by the uid manufacturer. Generally this time period is at least 24 hours.
• Warn others who may enter work area of hazard from exposure to isocyanates. Follow the recommen-
dations of the uid manufacturer and local regulatory authority. Posting a placard such as the follow-
ing outside the work area is recommended:
5
Warnings

Material Self-ignition
Some materials may become self-igniting if applied to thick.
Read material manufacturer’s warnings and Safety Data
Sheet (SDS).
Keep Components A and B
Separate
Cross-contamination can result in cured material in uid
lines which could cause serious injury or damage equip-
ment. To prevent cross-contamination:
• Never interchange component A and component B
wetted parts.
• Never use solvent on one side if it has been contami-
nated from the other side.
Moisture Sensitivity of
Isocyanates
Exposure to moisture (such as humidity) will cause ISO to partially
cure, forming small, hard, abrasive crystal that become suspend-
ed in the uid. Eventually a lm will form on the surface and the
ISO will begin to gel, increasing in viscosity.
NOTICE
Partially cured ISO will reduce performance and the life of all
wetted parts.
• Always use a sealed container with a desiccant dryer in
the vent, or a nitrogen atmosphere. Never store ISO in
an open container.
• Keep the ISO pump wet cup or reservoir (if installed)
lled with appropriate lubricant. The lubricant creates a
barrier between the ISO and the atmosphere.
• Use only moisture-proof hoses compatible with ISO.
• Never use reclaimed solvents, which may contain mois-
ture. Always keep solvent containers closed when not in
use.
• Always lubricate threaded parts with an appropriate lubri-
cant when reassembling.
NOTE: The amount of lm formation and rate of crystallization
varies depending on the blend of ISO, the humidity, and the tem-
perature.
Foam Resins with 245 fa
Blowing Agents
Some foam blowing agents will froth at temperatures abov 90 F
(33 C) when not under pressure, especially if agitated. To reduce
frothing, minimize preheating in a circulation system.
Changing Materials
NOTICE
Changing the material types used in your equipment requires
special attnetion to avoid equipment damage and downtime.
• When changing materials, ush the equipment multiple
times to ensure it is thoroughly clean.
• Always clean the uid inlet strainers after ushing.
• Check with your material manufacturer for chemical
compatibility.
• When changing between epoxies and urethanes or
polyureas, disassemble and clean all uid components
and change hoses. Epoxies often have amines on the B
(hardener) side. Poluureas often have amines on the B
(resin) side.
6
Warnings

Section 1 - Installation: Introduction
Introduction
Before operating, maintaining or servicing any Glas-
Craft system, read and understand all of the technical
and safety literature provided with GlasCraft products.
If you do not have the proper or related manuals and
safety literature for your GlasCraft system, contact your
GlasCraft distributor.
In this GlasCraft technical and safety publication, the
following advisories will be provided where appropriate:
Information about the procedure in progress.
Indicates a hazardous situation that can result in death
or serious injury.
The information in this document is intended only to indi-
cate the components and their normal working relationship
typical use. Each assembly should be directed by a Glas-
Craft distributor or made from the GlasCraft Assembly
instructions provided.
This manual provides information for the assembly, opera-
tion, maintenance and service of this GlasCraft product as
used in a typical conguration. While it lists standard speci-
cations and procedures, some deviations may be found.
In order to provide our users with the most up-to-date
technology possible, we are constantly seeking to improve
products. If a technological change occurs after a prod-
uct is on the market, we will implement that technology in
future production and, if practical, make it available to cur-
rent users as a retrot, update or supplement. If you nd
a discrepancy between your unit and the available docu-
mentation, contact your GlasCraft distributor to resolve the
difference.
Careful study and continued use of this manual will pro-
vide a better understanding of the equipment and process,
resulting in more efcient operation, longer trouble-free
service and faster, easier troubleshooting.
7
WARNING

8
Standard Equipment
Part
Number Description
GCP4RX Auto Probler P2 Dispense Gun
313267 User Manual
Section 1 - Installation: Standard Equipment

How The Gun Works
The air on / off ports actuate the gun’s piston. When air is
applied to the “on” port the air pressure forces the piston
towards the rear of the gun, simultaneously closing off the
purge air and moving the mixing chamber to a position
where the mixing chamber orices are aligned with the
orices in both, the side block seal and check valve assem-
blies.
The proper alignment of the orices is determined by
the setting of the adjustment nut, located on the pis-
ton lock assembly. This adjustment nut determines
the length of travel of the air piston and has been
preset at the factory and should not require adjust-
ment. (SEE MAINTENANCE SECTION)
The two uids (isocyanate and polyol) then ow through
the material shut-off valves, seal, and check valve assem-
blies and into the mixing chamber. The two uids impinge
against one another and exit the mixing chamber in a swirl-
ing, conical spray pattern.
When the trigger is released, the mixing chamber returns
to its original position and purge air ows into the mixing
chamber housing. The front tip o-ring, keeps air purge in-
side the gun head, forcing all of the air through the orices
in the mixing chamber, for a complete, total and constant
purge.
This purge air continues to ow through the mixing cham-
ber until the air switch is pulled up to shut-off all air to the
gun; or until the trigger is pulled again.
Piston Lock
Engage piston lock whenever you stop spraying, to avoid
accidental triggering.
Always use piston lock in conjunction with uid ball valves
to avoid accidental triggering.
Read warnings, page 3.
To engage Piston lock: push knob in and turn clockwise.
If engaged, gun will not actuate.
To disengage piston lock: push knob in and turn coun-
terclockwise until it pops out. There will be a gap between
knob and gun body.
See page 19 for piston lock adjustment or installation.
Loss of Air Pressure
In event of loss of air pressure, gun will continue to spray.
To shut off gun, do one of the following:
• Push in piston lock, see Engage piston lock.
• Close ball valves A and B.
9
Section 1 - Installation: Equipment Assembly
WARNING
r_257826_313266_1_1b
r_257826_313266_1_2b

10
Section 1 - Installation: Equipment Assembly
GlasCraft Equipment
Air Hose is 1/4” in. NPS
JIC and SAE Fittings DO NOT require the use of PTFE
tape.
Once the ttings are attached and tight, refer to system
manuals for start-up instructions.
*Fitting GC2394 is an unattached part that may need to be
connected to the air hose rst, and then connected to the
gun, depending on the air hose tting.
Installing Auto Probler P2on other
Equipment
Do not place any part of the body in the path of the
material spray. Do not point the gun at or near other
personnel. Do not look into the mixing chamber ori-
ce at any time. Because of the hazardous materials
used in this equipment, it is recommended that the
operator use an air mask, goggles, protective cloth-
ing, and other safety equipment as prescribed by
current regulations, recommendations of the chemi-
cal suppliers, and the laws in the area where the
equipment is being used.
If original equipment does not require the use of an un-
heated whip hose or isolation hose, the P2 can be directly
installed on to the material hose.
1. Remove the ttings from the original gun.
2. Remove swivel ttings from ball valves. Ball valves
are 1/8 in. NPT female. Remove swivel tting from
air slide valve. The air slide valve is a ¼ in. NPSM.
3. Install the original ttings into ball valves.
It is recommended to use a non-permanent thread
lock on the 1/8 in. NPT threads to assist as a sealant
and keep the ttings from twisting with gun move-
ment.
4. Install the gun on the original hoses.
Relieve ALL system uid and air pressure according
to manufacturer’s instructions.
WARNING
WARNING
ISO
*AIR
POLY
AIR “ON”
AIR “OFF” ti19821a
ti19822a
Otros manuales para Auto Probler P2
1
Este manual sirve para los siguientes modelos
8
Tabla de contenidos
Otros manuales de Dispensador de Glas Craft

Glas Craft
Glas Craft GCP3RA Manual de usuario

Glas Craft
Glas Craft MH II Manual de usuario

Glas Craft
Glas Craft GUARDIAN A5-3000 IP Manual de usuario

Glas Craft
Glas Craft Probler Manual de usuario

Glas Craft
Glas Craft GUARDIAN Manual de usuario

Glas Craft
Glas Craft Guardian A6-6000 IP Manual de usuario

Glas Craft
Glas Craft MH II Manual de usuario

Glas Craft
Glas Craft Guardian A5-6000 IP Manual de usuario

Glas Craft
Glas Craft Probler P2 Manual de usuario