System 3000
Presence and motion detector 360° top unit BT
Parameters Setting options, default set-
ting
Explanation
Using the current
brightness
The current brightness can
be stored in a range of 5 to
500 lx or 1000 lx.
Sets the brightness threshold parameter in the
app to the current brightness.
Sensor sensitivity 0, 25, 50, 75, 100 %
Default setting: 100%
Individually adjust the sensitivity in 5 steps for
each sensor A–C.
To restrict the detection field, switch off indi-
vidual sensors. To do this, set the sensitivity to
0 %.
Reduced basic
sensitivity
On, Off
Default setting: Off
Reduced basic sensitivity On:
Reduced basic sensitivity for use in environ-
ments with interference sources.
Presence simula-
tion
On, Off
Default setting: Off
The function can only be activated after more
than 24 hours of time was saved. In automatic
mode, the times at which the lighting was
switched on are continuously saved. A max-
imum of 60 switching operations are saved
over a period of 24 hours. If more switching
operations take place, the oldest ones are
overwritten respectively. If the presence simu-
lation is activated, the lighting is switched on
at the saved times depending on the bright-
ness. Switch-off takes place after the run-on
time has elapsed. Detected motions prolong
the run-on time or the light is switched on de-
pending on brightness. Times are not saved.
The dynamic run-on time is not taken into ac-
count.
Activating the day
operation
On, Off
Default setting: Off
In the setting day operation the device oper-
ates independently of the brightness.
Activating the
walking test
On, Off
Default setting: Off
Function for checking the detection field. The
function automatically terminates after
5 minutes.
Activate alarm
operation
On, Off
Default setting: Off
This function is used to monitor an area for un-
authorised access during absence. If this is
the case, the lighting flashes (1 second on, 1
second off) for the duration of the run-on time.
In addition, a message is sent via the
Bluetooth interface. When motions are detec-
ted, the run-on time is restarted.
Time change On, Off
Default setting: On
Activates automatic summer/wintertime
changeover
Settings only for switch inserts
Parameters Setting options,
default setting
Explanation
Switch-off pre-
warning
On, Off
Default setting:
Off
If the switch-off pre-warning is activated, the light is not
switched off immediately after the run-on time has
elapsed. Triple flashing at an interval of 10 seconds
shows that the light will be switched off soon. The run-
10 / 13
82599322 24.10.2019