Ghost Controls DTP1 Instrucciones de instalación

DTP1 GATE OPENER INSTALLATION AND OWNERS MANUAL
5004019
CONFORMS TO UL STD 325
A 12V BATTERY IS REQUIRED TO OPERATE OPENER AND IS INCLUDED!
*If using solar you will need to add another 12V Battery to your Battery Box Kit.
201812 DTP1IM
WARNING: This product can expose you to chemicals including lead, which is known to the
State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov

CONTACT US:
1572 Capital Circle NW, Tallahassee, FL 32303
www.ghostcontrols.com
For sales, product information, or to locate a retailer near you:
Call: 850-558-5520
Monday through Friday: 8:00–5:00 EST
For installation assistance and technical support:
Call: 850-898-1411
Monday through Friday: 8:00–5:30 EST
Product information, technical article, and installation videos can be found at:
myghostcontrols.force.com/Support/s or
Ghostcontrols.com/Support/Installation-Video
©Ghost Controls 2018

CONTENTS
Installation and Owners Manual
Warranty Registration page 5
Operator Specifications page 7
System Safety page 9
System Overview page 13
Installation Planning page 15
Tools Needed page 19
Included Parts page 20
PULLTOOPEN INSTALLATION page 21
Control Box Installation page 26
Battery Installation page 26
Connecting Arm to Control Box page 28
Setup System Controller page 29
Front Mount Gate Bracket Installation page 32
Setting the Closed Limit page 36
Powering the System AC page 37
Powering the System Solar page 38
Setting the Auto Close Feature page 39
PUSHTOOPEN INSTALLATION page 41
Control Box Installation page 46
Battery Installation page 46
Connecting Arm to Control Box page 48
Setup System Controller page 49
Front Mount Gate Bracket Installation page 52
Setting the Open Limit page 56
Powering the System AC page 57
Powering the System Solar page 58
Setting the Auto Close Feature page 59
Troubleshooting page 61
Connecting Optional Accessories page 63
Manual Gate Operation page 65
Accessories page 66
3
CONTENTS

BEFORE YOU BEGIN:
■A 12 volt automotive/marine battery or Ghost Controls ABBT Battery Box Kit is required to power the operator.
■Push-To-Open applications (gate that swings away from the property) will require the Ghost Controls push-to-open
bracket kit (AXPO).
■If charging your system with the AC transformer, you will need to purchase a 16 gauge stranded low voltage wire to
connect the transformer to the gate operator control board. Up to 1,000 ft. of wire can be used.
■For installations farther than 1,000 ft. from an AC power source, the Ghost Controls 10 Watt Solar Panel Kit (AXDP)
can be used to charge the battery. Up to 30 Watts of solar power can be used.
CUSTOMIZING YOUR GATE:
Information on additional accessories shown below can be found on the accessory page 66 or visit
www.ghostcontrols.com
INCLUDED IN DTP1 AND DEP2 KITS
ADDITIONAL ACCESSORIES
12V battery required and included
Opens gates up to 20 ft. or 1,000 lbs.
per gate leaf
Low Voltage Wire
(AXLV)
Wireless
Keypad (AXWK)
used for exit
of property
Safety Placards
DTP1 or DEP2
Operator Arm
5 Button
Transmitter
(AXP1)
3 Button
Transmitter
(AXS1)
4DTP1 SINGLE KIT
©Ghost Controls 2018

PROTECT YOUR INVESTMENT!
Get An Additional 6 Months Warranty when you register
your product(s) at ghostcontrols.com.
WARRANTY
REGISTER ONLINE WWW.GHOSTCONTROLS.COM
NOTE
If your unable to access the internet please fill out the warranty form below and mail in to us at Ghost Controls
1572 Capital Circle NW, Tallahassee, FL 32303
First Name:__________________________________________ Last Name: _________________________________
Street:___________________________________________________________ Apt. #: ___________________________
City : __________________________________________ State:_________________________ Zip: _______________
Phone Number: ___________________________________ Email Address: _________________________________
Items Purchased:
DTP1
DEP2
Where did you buy your gate opener system? (please include a copy of your receipt)
Type of gate you are using?
Chainlink Ornamental Tube Vinyl
Approximate Gate Weight:___________________ pounds per leaf
Approximate Gate Length:___________________ feet per leaf
Type of Application:
Farm Home Business
Item Serial Number:___________________ Item Serial Number: ___________________ Manufacturer Date:__________________
Did you purchase any accessories? (Please list below)
5
DTP1 SINGLE KIT
©Ghost Controls 2018

6BLANK PAGE

7
SPECIFICATIONS
©Ghost Controls 2018
SPECIFICATIONS
■Compliance: The operator is system certified to be in compliance
with UL325 Standard, 7th Edition
■System Operating Voltage: 12 VDC
■System Battery Type: Battery Box Kit (ABBT) included
■System Current: 1-2 Amps is typical when active.
Standby is 20 milliamps
■Operator Arm Maximum Stroke Distance: 23"
■Maximum Gate Length: 20'
■Operator Opening Speed: 90 degrees in approximately 15 seconds
■Maximum Operator Opening Range: 110 degrees
■Linear Actuator Operating Temperature: -5°F to 160°F
Maximum Gate
Length and
Weight
Max
900 lbs.
800 lbs.
700 lbs.
600 lbs.
500 lbs.
400 lbs.
350 lbs.
325 lbs.
300 lbs.
5' 6' 8' 10' 12' 14' 16' 18' 20'
DTP1 DTP1
DTP1
DTP1
DTP1
DTP1
DTP1
DTP1
DTP1
1000 lbs.
SPECIFICATIONS
DTP1 GATE OPERATOR KIT

8BLANK PAGE
©Ghost Controls 2018

9
SYSTEM SAFETY
©Ghost Controls 2018
This manual contains important safety precautions and
warnings for both the installer and end users or consumers
of this automatic gate opener system. The following warn-
ings and safety are intended to apply to the most common
applications but may not apply to all possible installation
and applications for these products. To reduce risk of
injury or death:
I. Carefully read and follow all safety precautions,
warnings, installation and operating instructions.
II. DO NOT ALLOW CHILDREN TO OPERATE
GATE CONTROLS. Do not allow children or pets
to play near the gate opener system. Keep all gate
control accessories such as remote transmitters,
keypads, and push buttons out of reach of children
and store in a secure area when not in use.
III. Understand how to disconnect the power and
manually open the gate (beginning on page 65)
BEFORE you begin using the gate opener system.
If you are unsure of any of these steps, please con-
tact GHOST CONTROLS®Technical Support at
850-898-1411 or online at https://myghostcontrols.
force.com/Support/s.
IV. Disconnect the gate operator from the gate only
when the gate is not in motion and the opener
system is turned o.
V. Moving gates can be dangerous. No one, including
people or animals, should cross the path of a moving
gate. Maintain a safe distance from moving parts
and avoid any areas where hands or fingers could
be pinched.
VI. Become familiar with potential entrapment zones as
shown below and avoid these areas when the gate is
turned on.
VII. The gate opener system must be installed only
in applications that it is specifically designed for
including: frequency of use, length, and weight
of the gate.
VIII. Install the gate operator system on the inside of
the property, gate, or fence line to prevent public
access to it. Most applications are installed in a pull-
to-open configuration so that the gate opens into
the property and away from any public roads.
IX. The control board for the gate operator system
should be protected from unauthorized access
inside the control box to prevent tampering or
adjustments to its setting once installed. The
control box is designed so that a padlock can be
attached to keep the box securely closed. An
accessory Clevis Pin (AXCL) is available for
purchase to secure the operator(s) to the gate
with a padlock.
X. Keypads and push-buttons to activate the gate
operator system must be a minimum of 10'away
IN DIRECT LINE OF SIGHT VISIBILITY TO
THE GATE so that the user can verify that any
potential entrapment areas are clear of potential
obstructions.
XI. The included warning signs must be attached to
each side of the gate to alert the public of the
automatic gate operator system. Please contact
GHOST CONTROLS®Technical Support for
replacement signs if yours become damaged.
XII.While the gate is moving do not drive into the gate
area to prevent entrapment and potential damage
to your vehicle, gate, AND the gate opener system.
XIII. Do not attempt to “race the gate” by driving
through the gate while it is opening or closing. This is
extremely dangerous and can cause damage to your
vehicle, gate, AND the gate opener system.
XIV.Maintain the gate and the gate opener system to
make sure that the gate continues to swing freely
and is level throughout the entire swing path.
The gate hinges should be lubricated regularly,
the condition of the battery checked every few
months, and all connections checked no less than
an annual basis.
XV. In the event that you sell the gate opener system
or your property with a system installed, please
provide these instructions to the new owners. The
most recent version of these instructions can be
found on our support website at https://myghost-
controls.force.com/Support/s.
SYSTEM SAFETY
GATE OPENER SYSTEMS

10 SYSTEM SAFETY
©Ghost Controls 2018
VEHICULAR GATE STANDARD
We recommend that all vehicular gates be constructed
and installed in accordance with Active Standard ASTM
F2200, Standard Specification for Automated Vehicular
Gate Construction. For more information on this standard,
contact ASTM directly at http://www.astm.org/Standards/
F2200.htm.
WARNING SIGNS
The included warning signs must be installed on both the
inside and outside of the gate.
! !
©GHOST CONTROLS 2016
1. Persons are to keep clear! The gate is able
to be moved without prior warning.
2. DO NOT let children operate the gare or
play in the gate area.
3. Persons are to operate the gate only when
the gate area is in sight and free of people
and obstructions.
4. Persons are to read the user’s manual and
safety instructions.
WARNING
ALARM
Your GHOST CONTROLS®Gate Operator system
includes an audible alarm. This alarm will continue to
sound for 5 minutes when two sequential obstructions
are detected during gate travel per UL325 safety
standards or until one of the following occurs:
■The gate operator receives an intended signal from a
hard wired entry/exit source such as a push button or
a wired keypad. Note that wireless transmitters and
wireless keypads cannot deactivate the alarm.
■The gate operator system is powered o and then on
again at the main power switch in the control box.
NOTE
The alarm may also be used as audio feedback for other
modes of operation under normal operation.
SWING GATE PROTECTION AND
ENTRAPMENT ZONES
As specified in Gate Operator Safety Standard, UL325
(30A 1.1) 7th Edition, all gate operators must include
two independent means of entrapment protection. All
GHOST CONTROLS®Automatic Gate opener systems
meet this standard as indicated on the product packaging
through the following:
1. TYPE A Inherent.
2. Number one above AND either of the following two
options:
A. TYPE C Inherent force limiting.
B. TYPE B1 and B2 monitored contact and non-
contact sensors.
If you have questions about compatibility of third
party safety devices, please contact GHOST
CONTROLS®technical support for assistance
at https://myghostcontrols.force.com/Support/s.
Refer to the monitored photo eye instructions for proper
placement of the sensors. Proper installation of these
sensors is critical to avoid false tripping while gate is in
motion and to reduce potential entrapment.
CAUTION
Extreme caution must be exercised when automatic
gate opener system is in operation, regardless of which
safety systems are installed and in use.
Otros manuales para DTP1
1
Tabla de contenidos
Otros manuales de Abridor de puerta de Ghost Controls

Ghost Controls
Ghost Controls Ghost Pro LSM1 Instrucciones de instalación

Ghost Controls
Ghost Controls DTP1XP Instrucciones de instalación

Ghost Controls
Ghost Controls TSS1 Instrucciones de instalación

Ghost Controls
Ghost Controls HDP1 Instrucciones de instalación

Ghost Controls
Ghost Controls TDS2 Instrucciones de instalación

Ghost Controls
Ghost Controls DTP1 Manual de usuario

Ghost Controls
Ghost Controls DEP2 Instrucciones de instalación

Ghost Controls
Ghost Controls HDP1 Instrucciones de instalación

Ghost Controls
Ghost Controls HDP2 Instrucciones de instalación

Ghost Controls
Ghost Controls Ghost Pro Series Instrucciones de instalación