
Guarantee
Genelec guarantees the 9301B for ve years
against manufacturing faults or defects
altering performance. Refer to the reseller
for full sales and guarantee terms.
Safety Considerations
The 9301B has been designed in accordance
with international safety standards. To ensure
safe operation, the following warnings and
precautions must be observed:
• Servicing and adjustment must only be
performed by Genelec certied service
personnel.
• The enclosure must not be opened.
• Do not use this product with a mains
cable or mains outlet having no protective
earth (potential equalizing) connection as
doing so may result in personal injury.
• To prevent re or electric shock, do not
expose the unit to water or moisture.
• Do not place objects lled with liquid,
such as vases, on the 9301B or near it.
• The 9301B is not completely
disconnected from the mains power
unless the mains cable is removed from
the device or the mains outlet.
Compliance to FCC Rules
This device complies with part 15 of the FCC
Rules. Operation is subject to the following
two conditions:
• This device may not cause harmful
interference, and
• This device must accept any interference
received, including interference that may
cause undesired operation.
Note: This equipment has been tested
and found to comply with the limits for a
Class B digital device, pursuant to part
15 of the FCC Rules. These limits are
designed to provide reasonable protection
against harmful interference in a residential
installation. This equipment generates, uses,
and can radiate radio frequency energy
and, if not installed and used in accordance
with the instructions, may cause harmful
interference to radio communications.
There is no guarantee that interference will
not occur in a particular installation. If this
equipment does cause harmful interference
to radio or television reception, which can
be determined by turning the equipment o
and on, the user is encouraged to try and
correct the interference by one or more of
the following measures:
• Reorient or relocate the receiving
antenna.
• Increase the separation between the
equipment and receiver.
• Connect the equipment into an outlet on
a circuit dierent from that to which the
receiver is connected.
• Consult the dealer or an experienced
radio/TV technician for help.
• Modications not expressly approved
by the manufacturer can void the user’s
authority to operate the equipment under
FCC rules.
Indicator Colour, indication Meaning
Power switch Solid green Power on, normal operation
Blinking green GLM is adjusting 9301B
Green blink every 10 s 9301B in power save mode
No light No power, power o
Input signal indicator Solid green Valid digital audio is detected and
received
No light Valid input is not detected
Acoustic Calibration
To acoustically calibrate your setup, place
the Genelec measurement microphone on a
microphone stand and put the microphone
at the listening location pointing upwards
with the microphone top at the listener’s ear
height. Then, follow instructions in the GLM
software to calibrate your monitors and
subwoofers.
Genelec recommends using the GLM
software and having the GLM network
connected.
When you do not wish to have the
computer connected after calibration,
you have the option to save the acoustic
calibration into monitors, subwoofers, and
9301B units. This enables the calibration
with the GLM network disconnected. The
settings can be stored into the 9301B using
GLM software menu item ‘Store | Store the
Current Group Settings...’. Note that the
monitors and subwoofers have a switch
selecting the use of the stored settings,
and this switch must be set ON to operate
the system without computer and GLM
network. Removing the GLM network cable
and powering down and up the 9301B and
monitors enables the stored settings.
Returning to factory settings
The room settings stored in a 9301B can
be erased by keeping the power switch
depressed for more than 10 seconds. This
returns the 9301B to factory settings. After
this, GLM software should be used to
recongure the system.
Operating Environment
The 9301B is designed for indoor use only.
The permissible ambient temperature is
15-35 degrees Celsius (50-95°F) and relative
humidity 20% to 80% (noncondensing).
When the product has been stored or
transported in cool environment and is taken
into a warm room, wait 30-60 minutes before
opening packing to prevent condensation.
Sufficient cooling must be ensured. No
minimum clearance is needed.
Maintenance
There are no user serviceable parts inside
the 9301B. Maintenance or repair must
only be done by Genelec-certied service
personnel.