1GENERAL INFORMATION
The manual is meant to familiarize the user with the operation of a solid fuel boiler.
Every user should read the manual for the boiler and controller before installation and
use. It contains recommendations for proper handling and use of the boiler. Failure to
comply with the rules and guidelines presented in this manual releases the boiler
manufacturer from all liability and warranty obligations. Boilers are equipped with a
thermometer and, optionally, a draught regulator, or a fan and an electronic "LUKSUS"
controller, which controls the operation of the boiler (fan and pumps installed in the
heating system). The boiler should be operated only by an adult. A complete cleaning of
the boiler should be done at least once a month during the heating season. The boilers
are built with a fixed water-cooled grate - KWR, and a removable cast iron grate -
KW. Satisfaction with the use of the boiler can be achieved only when appropriate fuel
with a high calorific value and adequate granulation is used.
1.1 Application
Steel boilers of the GT-KW, GT-KWR, GT-KWRU, GT-KWRUZ types are
intended for heating single-family houses equipped with hydronic central
heating of an open type system with gravitational or forced circulation. The
system, within which the boiler operates, must be equipped with safety features
in accordance with the requirements of the PN-91/B-02413 standard, with a
maximum operating temperature of 95°C. Boilers are not subject to registration
with the district Technical Inspection Office.
Selecting boiler power depending on the insulation of the building
(for demand for heat equal to 60 –40 W/m3)